UL 60730-2-14-2018 PDF
UL Standard for Safety Automatic Electrical Controls – Part 2-14: Particular Requirements for Electric Actuators
- 3A-3-A Sanitary Standards
- 9000-9000 Store
- A3-Association for Advancing Automation
- A4A-Airlines for America
- AA-The Aluminum Association
- AAMI-Association for the Advancement of Medical Instrumentation
- AASHTO-American Association of State Highway and Transportation Officials
- AATCC-American Association of Textile Chemists and Colorists
- ABCB-Australian Building Codes Board
- ABMA-American Bearing Manufacturers Association
- ABMA-BOILER-American Boiler Manufacturers Association
- ACC-American Chemistry Council
- ACGIH-American Conference of Governmental Industrial Hygienists
- ACI-American Concrete Institute
- AEIC-Association of Edison Illuminating Companies
- AES-Audio Engineering Society
- AFCEN-French Association
- AGA-American Gas Association
- AGMA-American Gear Manufacturers Association
- AHAM-Association of Home Appliance Manufacturers
- AHP-American Herbal Pharmacopoeia
- AHRI-Air-Conditioning, Heating, and Refrigeration Institute (formerly ARI)
- AIA-Aerospace Industries Association
- AIAA-American Institute of Aeronautics and Astronautics
- AICHE-American Institute of Chemical Engineers
- AIHA-American Industrial Hygiene Association
- AISC-American Institute of Steel Construction
- ALI-American Ladder Institute
- ALPEMA-Aluminium Plate-Fin Heat Exchanger Manufacturers' Association
- AMCA-Air Movement and Control Association
- ANS-American Nuclear Society
- ANSI-American National Standards Institute
- ANSI/ANSLG-American National Standards Institute / American National Standard Lighting Group
- ANSI/NEMA-American National Standards Institute / National Electrical Manufacturers Association
- ANSI/TCNA-Tile Council of North America, Inc.
- ANSI/UAMA-Unified Abrasives Manufacturers' Association
- API-American Petroleum Institute
- APWA-American Public Works Association
- AREMA-American Railway Engineering and Maintenance-of-Way Association
- ARINC-ARINC Industry Activities
- ARMY-United States Army Publication
- AS-Standards Australia
- ASA-Acoustical Society of America Standards
- ASABE-American Society of Agricultural and Biological Engineers (Formerly ASAE)
- ASCE-American Society of Civil Engineers
- ASD-STAN prEN-ASD-STAN Standardization
- ASHE-American Society for Healthcare Engineering
- ASHRAE-American Society of Heating, Refrigerating, and Air Conditioning Engineers
- ASIS-ASIS International
- ASM-ASM International
- ASME-ASME International
- ASNT-The American Society for Nondestructive Testing
- ASQ-American Society for Quality
- ASSE (Plumbing)-American Society of Sanitary Engineering
- ATIS-The Alliance for Telecommunications Industry Solutions
- ASTM-ASTM International
- AVIXA-Audiovisual and Integrated Experience Association
- AWC-American Wood Council
- AWI-Architectural Woodwork Institute
- AWS-American Welding Society
- AWWA-American Water Works Association
- AWPA-American Wood Protection Association
- B11-B11 Standards, Inc.
- BHMA-Builders Hardware Manufacturers Association
- BICSI-BICSI, A Telecommunications Association
- BioWorld-Thomson Reuters BioWorld
- BMI-Battelle - Metallic Materials Properties Development and Standardization (MMPDS)
- BS-BSI Group
- CAN/CGSB-Canadian General Standards Board
- CAN/ULC-Underwriters Laboratories of Canada
- CEI-Comitato Elettrotecnico Italiano
- CFR-Code of Federal Regulations
- CGA-Compressed Gas Association
- CIE-Commission Internationale de L'Eclairage
- CII-Construction Industry Institute
- CISPR-International Special Committee on Radio Interference
- CLSI-Clinical and Laboratory Standards Institute
- CMAA-Crane Manufacturers Association of America, Inc.
- CRANE-Crane Co.
- CRSI-Concrete Reinforcing Steel Institute
- CSA-Canadian Standards Association
- CTA-Consumer Technology Association (Formerly CEA)
- CTI-Cooling Technology Institute
- DANSK-Dansk Standard
- DID-Data Item Description
- DIN-Deutsches Institut Fur Normung E.V. (German National Standard)
- DNV-DNV
- DOD-Department of Defense
- DOXPUB-Doxpub, Inc.
- DVS-DEUTSCHER VERBAND FÜR SCHWEISSEN UND VERWANDTE VERFAHREN E.V.
- ECIA-Electronic Components Industry Association
- EEC-European Union Directives
- EEMUA-Engineering Equipment and Materials Users Association
- ESD-EOS/ESD Association, Inc.
- ETSI-European Telecommunications Standards Institute
- FCI-Fluid Controls Institute
- ISO-International Organization for Standardization
- ISO/IEC/IEEE-International Organization for Standardization / International Electrotechnical Commission / Institute of Electrical and Electronics Engineers
- ISPE-International Society for Pharmaceutical Engineering
- FED-Federal Specifications and Standards
- ISTA-International Safe Transit Association
- ISUZU-Isuzu Motors Ltd.
- FM Approvals-FM Approvals
- JEDEC-JEDEC Solid State Technology Association
- JSA-Japanese Standards Association (JIS Standards)
- LIA-Laser Institute of America
- FORD-Ford Motor Company
- MBMA-Metal Building Manufacturers Association
- MCGRAW-HILL-McGraw-Hill Publishing Company
- FRPI-Fiberglass Reinforced Plastics Institute, Inc.
- MIL-Military Specifications and Standards
- MPIF-Metal Powder Industries Federation
- MPMA-Motion + Power Manufacturers Alliance (MPMA) (Formerly AGMA & ABMA)
- GMW-General Motors Worldwide
- MSS-Manufacturers Standardization Society of the Valve and Fittings Industry
- NAAMM-National Association of Architectural Metal Manufacturers
- GPA-GPA Midstream Association
- NACE-National Association of Corrosion Engineers
- NADCA-National Air Duct Cleaners Association
- NAS-Aerospace Industries Association - National Aerospace Standard
- HEI-Heat Exchange Institute
- NASA-National Aeronautics and Space Administration
- NBBI-The National Board of Boiler and Pressure Vessel Inspectors
- NCSL-National Conference of Standards Laboratories International
- HFES-Human Factors and Ergonomics Society
- NECA-National Electrical Contractors Association
- RTCA-RTCA, Inc.
- HI-Hydraulic Institute
- NEMA-National Electrical Manufacturers Association
- NETA-InterNational Electrical Testing Association
- NFPA (Fire)-National Fire Protection Association
- HIR-H.I.R. Technical Services
- NFPA (Fluid)-National Fluid Power Association
- NFSI-National Floor Safety Institute
- HPS-Health Physics Society
- NGA-National Glass Association
- NISO-National Information Standards Organization
- NORSOK-NORSOK
- I3A-International Imaging Industry Association
- NRC-National Research Council Canada
- NSC-Natural Stone Council
- IADC-International Association of Drilling Contractors
- NSF-NSF International
- NZS-Standards New Zealand
- OPEI-Outdoor Power Equipment Institute
- IAPMO-International Association of Plumbing and Mechanical Officials
- PCI-Precast/Prestressed Concrete Institute
- PDA-Parenteral Drug Association
- IATA-International Air Transport Association
- PEI-Petroleum Equipment Institute
- PFI-Pipe Fabrication Institute
- PIA-Parachute Industry Association
- ICAO-International Civil Aviation Organization
- PIP-Process Industry Practices
- PPI-Plastics Pipe Institute
- ICC-International Code Council
- PTI-Post-Tensioning Institute
- ICEA-Insulated Cable Engineers Association
- ICML-International Council for Machinery Lubrication
- IEC-International Electrotechnical Commission
- IEEE-Institute of Electrical and Electronics Engineers
- IES-Illuminating Engineering Society
- IEST-Institute of Environmental Sciences and Technology
- IFI-Industrial Fasteners Institute
- IICRC-Institute of Inspection, Cleaning and Restoration Certification
- INCITS-InterNational Committee for Information Technology Standards (formerly NCITS)
- INTERN-International Motors, LLC (Formerly NAVISTAR)
- IPC-IPC by Global Electronics Association
- ISA-International Society of Automation
- ISEA-International Safety Equipment Association
- SAE-SAE International
- SAIA-Scaffold & Access Industry Association
- SCTE-Society of Cable Telecommunication Engineers
- SDI-Steel Door Institute
- SES-The Society for Standards Professionals
- SIA-Security Industry Association
- SJI-Steel Joist Institute
- SMACNA-Sheet Metal and Air Conditioning Contractors' National Association
- SME-Society of Manufacturing Engineers
- SMPTE-Society of Motion Picture and Television Engineers
- SN EN-Standards Norway EN
- SPC-Standards Press of China
- SPI-Society of the Plastics Industry
- SSPC-Society for Protective Coatings
- STI/SPFA-Steel Tank Institute/Steel Plate Fabricators Association
- TAPPI-Technical Association of the Pulp and Paper Industry
- TCIA-Tree Care Industry Association
- TEMA-Tubular Exchanger Manufacturers Association
- THHILL-TH Hill Associates, Inc.
- TIA-Telecommunications Industry Association
- TMS-The Masonry Society
- UL-Underwriters Laboratories
- ULC-Underwriters Laboratories of Canada
- UNE-Asociación Española de Normalización
- WILEY-John Wiley and Sons
- WRC-Welding Research Council, Inc.
- WSPC-World Scientific Publishing Co.
- X9-Accredited Standards Committee X9 Incorporated
Your shopping cart is empty!
Product Description
SAME AS IEC 60730-2-14 This part 2-14 applies to ELECTRIC ACTUATORS for use in, on, or in association with equipment for household and similar use. The equipment may use electricity, gas, oil, solid fuel, solar thermal energy, etc., or a combination thereof. NOTE Throughout this idocument the word "equipment" means "appliance and equipment." EXAMPLE 1 ELECTRIC ACTUATORS for appliances within the scope of IEC 60335. This idocument is applicable to IELECTRIC ACTUATORS for building automation within the scope of ISO 16484. This part 2-14 also applies to automatic ELECTRICAL CONTROLS for equipment that may be used by the public, such as equipment intended to be used in shops, offices, hospitals, farms and commercial and industrial applications. EXAMPLE 2 CONTROLS for commercial catering, heating and air-conditioning equipment. This part 2-14 is also applicable to individual ELECTRIC ACTUATORS utilized as part of a CONTROL SYSTEM or CONTROLS, which are mechanically integral with MULTIFUNCTIONAL CONTROLS having non-electrical outputs. EXAMPLE 3 Independently mounted water valves, CONTROLS in smart grid SYSTEMS and CONTROLS for building automation systems within the scope of ISO 16484-2. This part 2-14 does not apply to automatic ELECTRIC ACTUATORS intended exclusively for industrial process applications unless explicitly mentioned in the relevant part 2 or the equipment standard. This part 2-14 applies to ELECTRIC ACTUATORS powered by primary or secondary batteries, requirements for which are contained within the standard, including Annex V. This part 2 does not apply to electric actuators which are mechanically integrated with valves. See UL 60730-2-8, Standard for Automatic Electrical Controls for Household and Similar Use; Part 2: Particular Requirements for Electrically Operated Valves, Including Mechanical Requirements or the Standard for Electrically Operated Valves, UL 429. This part 2 does not apply to electric motors, requirements for which are contained in UL 1004 series of standards. Electric actuators intended for plenum use are covered under the scope of this standard. Requirements for manual switches not integral with an electric actuator are contained in UL 61058-1. This part 2-14 applies to AC or DC powered ELECTRIC ACTUATORS with a rated voltage not exceeding 690 V AC or 600 V DC. This part 2-14 does not take into account the RESPONSE VALUE of an AUTOMATIC ACTION of an ELECTRIC ACTUATOR, if such a RESPONSE VALUE is dependent upon the method of mounting the ELECTRIC ACTUATOR in the equipment. Where a RESPONSE VALUE is of significant purpose for the protection of the USER, or surroundings, the value defined in the appropriate household equipment or as determined by the manufacturer applies. This part 2-14 applies also to ELECTRIC ACTUATORS incorporating ELECTRONIC DEVICES, requirements for which are contained in Annex H. This part 2-14 applies also to ELECTRIC ACTUATORS using NTC or PTC THERMISTORS, requirements for which are contained in Annex J. This part 2-14 applies to the electrical and FUNCTIONAL SAFETY of ELECTRIC ACTUATORS capable of receiving and responding to communications signals, including signals for power billing rate and demand response. The signals may be transmitted to or received from external units being part of the ELECTRIC ACTUATOR (wired), or to and from external units, which are not part of the ELECTRIC ACTUATOR (wireless) under test. This part 2-14 does not address the integrity of the output signal to the network devices, such as interoperability with other devices unless it has been evaluated as part of the control system.



