ULC CAN/ULC-S2577-13-2013 PDF

ULC CAN/ULC-S2577-13-2013 PDF

STANDARD FOR SUSPENDED CEILING POWER GRID SYSTEMS AND EQUIPMENT

$131.00 $262.00 -50%
Product Code: ULC CAN/ULC-S2577-13
Stock In Stock
Edition: 1
Published: 02/07/2013
Number of Pages: 56
File Size: 1 file, 440 KB

Available Options

Product Description

SAME AS UL 2577 These requirements cover suspended ceiling grid low voltage/extra-low voltage systems and equipment intended for installation and use in accordance with the: In Canada: Canadian Electrical Code, Part I, Safety Standard for Electrical Installations, CSA C22.1, In the United States: National Electrical Code (NEC), ANSI/NFPA 70. The suspended ceiling grid low voltage/extra-low voltage systems covered by this standard are intended to be installed as a suspended ceiling grid that provides mechanical support for the ceiling tiles and provides electrical connections between the low voltage/extra-low voltage power supply and the low voltage/extra-low voltage equipment. The low voltage/extra-low voltage system consists of the following components: a) An isolating type low voltage/extra-low voltage power supply with output(s) operating at 30 V (42.4 V peak) or less and not exceeding Class 2 power limits, b) A grid rail power distribution system to provide power from the Class 2 power supply to one or more pieces of Class 2 powered equipment, and c) Class 2 powered equipment that is electrically connected to the suspended ceiling grid low voltage/extra-low voltage system. The suspended ceiling grid low voltage/extra-low voltage system is intended to be permanently connected, for indoor dry locations, and installed in accordance with the following requirements: In Canada: Canadian Electrical Code, Part I, Safety Standard for Electrical Installations, CSA C22.1, and the National Building Code of Canada. In the United States: National Electrical Code (NEC), ANSI/NFPA 70, the International Building Code (IBC), and the International Mechanical Code (IMC). This standard also covers suspended ceiling grid low voltage/extra-low voltage systems intended for use in air-handling spaces. This standard does not address any supplemental or alternative requirements for suspended ceiling grid low voltage/extra-low voltage systems intended for use in: In Canada: a) Hazardous locations as specified in the Canadian Electrical Code, Part I, Safety Standard for Electrical Installations, CSA C22.1; b) General patient care areas or critical patient care areas as defined by Section 24 of the Canadian Electrical Code, Part I, Safety Standard for Electrical Installations, CSA C22.1; or c) Emergency systems as defined by Section 46 of the Canadian Electrical Code, Part I, Safety Standard for Electrical Installations, CSA C22.1. In the United States: a) Hazardous locations as specified in the National Electrical Code (NEC), ANSI/NFPA 70; b) General patient care areas or critical patient care areas as defined by Article 517 of the National Electrical Code (NEC), ANSI/NFPA 70; or c) Emergency systems as defined by Article 700 of the National Electrical Code (NEC), ANSI/NFPA 70. This standard does not evaluate the suspended ceiling grid low voltage/extra-low voltage system for seismic requirements in accordance with the: In Canada: National Building Code of Canada. In the United States: International Building Code (IBC). This standard does not evaluate the suspended ceiling grid low voltage/extra-low voltage systems for fire resistance.

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
ULC CAN/ULC-S2577-13-2013 PDF

ULC CAN/ULC-S2577-13-2013 PDF

$131.00 $262.00