ASTM C1649-25 PDF

ASTM C1649-25 PDF

Standard Practice for Instrumental Transmittance Measurement of Color for Flat Glass, Coated and Uncoated

$32.00 $64.00 -50%
Product Code: ASTM C1649
Stock In Stock
Published: 2025
Number of Pages: 3

Available Options

Product Description

Significance and Use
 4.1  Color measurement quantifies the transmitted color for glass. The user defines an acceptable range of color appropriate for the end use. A typical quality concern for transmittance color measurement of glass products is verification of lot-to-lot color consistency for end-user acceptance.
 4.2  If the transmitted color of a glass product is consistent from lot-to-lot and within agreed supplier-buyer acceptance criteria, the product’s color is expected to be consistent and acceptable for end-use.
 Scope
 1.1  This practice provides guidelines for the instrumental transmittance measurement of the color of coated and uncoated transparent glass. (See Terminology E284 .)
 1.2  The practice specifically excludes fluorescent and iridescent samples.
 1.3  The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.
 1.4   This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
 1.5   This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
ASTM C1649-25 PDF

ASTM C1649-25 PDF

$32.00 $64.00