ASTM D8686-26 PDF

ASTM D8686-26 PDF

Standard Practice for Measurement of Volatile Organic Compounds Using H 3 O + Ionization Proton-Transfer Reaction Mass Spectrometry (PTR-MS) for Indoor Environments

$52.00 $104.00 -50%
Product Code: ASTM D8686
Stock In Stock
Published: 2026
Number of Pages: 24

Available Options

Product Description

Significance and Use
 5.1  This practice serves as a detailed reference for measuring the concentration of VOCs using real-time H 3 O + proton-transfer reaction mass spectrometry in indoor environments.
 5.2  This practice frequently makes recommendations to set up, maintain, and operate an instrument such that data are collected under conditions described as expected or acceptable. Expected or acceptable operation and performance values should be defined by the operator or manufacturer, or both.
 5.3  Indoor environments may include residences, offices, environmental chambers, and heating-ventilation-air-conditioning (HVAC) systems, to name a few examples. Although aspects of this practice could apply to proton-transfer reaction mass spectrometry applications for outdoor air measurements, it has not been written with considerations specific to measurements of outdoor air (for example, temperature, humidity, concentrations) including mobile sampling platforms (for example, airplanes, cars).
 5.4  This practice is intended to serve as a collection of best practices for an operator to review before deploying a PTR-MS for measurements. General workflows are provided in some sections to communicate these best practices, but the operator should verify if additional instrument-specific operations or data treatments may be needed as described in instrument documentation or as recommended by the manufacturer. As such, this practice also identifies sources of uncertainty in proton-transfer reaction mass spectrometry measurements. However, this practice does not cover fundamentals of ion chemistry ( 1 ) or mass spectrometry ( 2 ) .
 5.5  This practice was written to anticipate the needs of operators using H 3 O + chemical ionization, but much of the information contained herein is directly applicable to field-deployable real-time mass spectrometers using other reagent ions.
 5.6  H 3 O + proton-transfer reaction mass spectrometry is not sensitive to some chemicals (for example, linear alkanes with five carbon atoms or less). Chemicals with proton-transfer enthalpies close to that of water (for example, formaldehyde) or vapor pressures lower than 10 -2 kPa at 25 °C can be challenging to quantify with a PTR-MS. Most PTR-MS instruments will also not be able to measure peroxides because typical ion-molecule reaction energies are high enough to completely dissociate peroxides. Although most of the guidance in this practice was written for VOC measurements, the information in this practice largely also applies to non-VOC chemicals (for example, NH 3 , H 2 S, etc.). An operator should consult the manufacturer with questions about how to optimize their instrument for measurement of non-VOC chemicals.
 5.7  Isomers and interfering product ions present important challenges for accurate identification and quantification of ions measured using proton-transfer reaction mass spectrometry. Guidance on identification of possible ion interferences is provided in 10.4.1 . Correcting for such interferences, and validating methods of correction, is not covered in this practice, but useful references are provided in 10.4.1 for an operator to consult for more information on this topic. Gas chromatography pre-separation or use of different reagent ions, or both, can aid in identification of isomers and ion interferences, but use of such methods is outside the scope of this practice. Recommendations on how to acknowledge structural ambiguity in the reporting of ions measured from samples are provided in 10.5.2 .
 5.8  Guidance herein was developed with an emphasis on sampling air from indoor environments that was not collected in a bag or canister. However, procedures to operate a PTR-MS and analyze data collected from the instrument described here are applicable to measurements from bag and canister samples. This practice refers to Test Method D5466 for information on sampling from canisters.
 Scope
 1.1  This practice covers procedures for measurement of volatile organic compounds (VOCs) using hydronium ion (H 3 O + ) ionization proton-transfer reaction mass spectrometry (PTR-MS) under environmental conditions that are typical of those found in indoor environments, such as offices, residential buildings, and test chambers. Procedures to prepare and initialize an instrument for measurement, construct a sampling line and characterize performance, and convert instrument signal into indoor air concentrations are outlined. These procedures can be used to develop standard operating procedures for specific PTR-MS applications.
 1.2  The scope is limited to PTR-MS and is not inclusive of other reagent ions that can be used in real-time chemical ionization mass spectrometers.
 1.3  PTR-MS is used in this practice to describe a chemical ionization mass spectrometer that satisfies all the following criteria: capable of ionizing analytes with H 3 O + as the primary reagent ion, real-time (that is, at least 1 Hz) data acquisition, and is field-deployable. From this point on all instances of PTR-MS refer to the instrument and “proton-transfer reaction mass spectrometry” will be used when referring to the technique.
 1.4  Because the logistics and data quality objectives of each application using a PTR-MS will be unique, standardized procedures for measuring the concentrations of specific gases are not explicitly set forth in this practice. Instead, general procedures that are applicable to all PTR-MS instruments and most applications are described. Users should consult manufacturers for instrument-specific guidance or refer to scientific literature, or both, when considering applications not covered by this practice.
 1.5  This practice describes procedures appropriate for both short-term (for example, minutes to hours) and long-term (for example, days to weeks) sampling of indoor air.
 1.6   Units— The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
 1.7   This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
 1.8   This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
ASTM D8686-26 PDF

ASTM D8686-26 PDF

$52.00 $104.00