Significance and Use
 5.1  Accurate determination of the density, relative density (specific gravity), or API gravity of petroleum and its products is necessary for the conversion of measured volumes to volumes or masses, or both, at the standard reference temperatures of 15 °C or (60 °F) during custody transfer.
 5.2  This procedure is most suitable for determining the density, relative density, or API gravity of low viscosity transparent liquids. This procedure can also be used for viscous liquids by allowing sufficient time for the hydrometer and temperature measuring device to reach temperature equilibrium, and for opaque liquids by employing a suitable meniscus correction. Additionally for both transparent and opaque fluids the readings shall be corrected for the thermal glass expansion effect on the hydrometer body and alternative calibration temperature effects (if applicable) before correcting to the reference temperature.
 5.3  When used in connection with bulk oil measurements, volume correction errors are minimized by observing the hydrometer reading at a temperature close to that of the bulk oil average temperature.
 5.4  Density, relative density, or API gravity is a factor governing the quality and pricing of crude petroleum. However, this property of crude petroleum and petroleum products is an uncertain indication of its quality unless correlated with other properties. This correlation may be used to give approximate hydrocarbon composition and heat of combustion.
 5.5  Density is an important quality indicator for automotive, aviation and marine fuels, where it affects storage, handling and combustion.
 Scope
 1.1  This test method covers the laboratory determination using a glass hydrometer and a separate temperature measuring device in conjunction with a series of calculations, of the density, relative density, or API gravity of crude petroleum, petroleum products, or mixtures of petroleum and nonpetroleum products normally handled as liquids, and having a Reid vapor pressure (Test Method D323 ) of 101.325 kPa (14.696 psi) or less. Values are determined at existing temperatures and corrected to values at 15 °C (or 60 °F) by means of a series of calculations and international standard tables.
 1.1.1  Alternative temperature measuring devices shall be either the appropriate liquid-in-glass ASTM thermometers meeting either Specifications E1 or E2251 or digital contact thermometers (Guides E2877 and D8164 ).
 1.2  The initial hydrometer readings obtained are uncorrected hydrometer readings and not density measurements. Readings are measured on a hydrometer at either the reference temperature or at another convenient temperature, and readings are corrected for the meniscus effect, the thermal glass expansion effect, alternative calibration temperature effects and to the reference temperature by means of calculations and Adjunct to D1250 Guide for the Use of the Petroleum Measurement Tables (API MPMS Chapter 11.1). Values measured (determined) at other than the reference temperature being hydrometer readings and not density measurements.
 1.3  The initial hydrometer readings (including temperature) determined in the laboratory shall be recorded before performing any calculations. Then the calculations required in Section 10 shall be performed, and applied to the initial hydrometer reading with observations and results reported and documented as required by Section 11 prior to use in a subsequent calculation procedure, such as (ticket calculation, meter factor calculation, or base prover volume determination).
 1.4  The initial hydrometer readings determined as density, relative density, or API gravity may be converted to equivalent values in the other units or alternative reference temperatures by means of Interconversion Procedures (API MPMS Chapter 11.5), or Adjunct to D1250 Guide for Petroleum Measurement Tables (API MPMS Chapter 11.1), or both, or tables, as applicable.
 1.5  The values stated in SI units are to be regarded as standard.
 1.5.1   Exception— The values given in parentheses are mathematical conversions (of) SI units that are provided for information only and are not considered standard.
 1.5.2   Exception— The values for API Gravity are only expressed in inch-pound units. Therefore, the SI values are only the mathematical conversions of inch-pound units and are not considered standard.
 1.6   Annex A1 , Annex A2 , and Annex A3 contains procedures for determining fit-for-service, verifying or certifying the equipment for this test method.
 1.7   This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
 1.8   This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.