Significance and Use
 5.1  Refer to Practice E261 for a general discussion of the determination of fast-neutron fluence rate with fission detectors.
 5.2   237 Np is available as metal foil, wire, or oxide powder. For further information, see Guide E844 . It is usually encapsulated in a suitable container to prevent loss of, and contamination by, the 237 Np and its fission products. 5
 5.3  One or more fission products can be assayed. Pertinent data for relevant fission products are given in Tables 1 and 2 .
 (A)   The lightface numbers in parentheses are the magnitude of plus or minus uncertainties in the last digit(s) listed.
 (B)   Decay gamma from 137 Cs beta decay, which produces 137m Ba, τ( 137m Ba) = 2.5545 (13) min, is in transient equilibrium with 137 Cs, τ( 137 Cs) = 30.018 (22) year. The 137m Ba decay radiation provides an alternate dosimetry metric for some applications.
 (C)   Photon decay probability of subsequent daughter 140 La decay.
 (D)   With 140 La, τ( 140 La) = 1.67858 (21) d, in transient equilibrium with 140 Ba, τ( 140 Ba) = 12.753 (5) d, the ratio of 140 La decays to 140 Ba decays is given by τ( 140 Ba)/[τ( 140 Ba)–τ( 140 La)] = 1.151573. When 140 La is the activity measurement, the 140 Ba decay probability is equal to this ratio multiplied by the 140 La probability of gamma emission in decay. The 140 Ba decay probability is then used, in conjunction with the fission yields in Table 2 , to provide a dosimetry metric for the 237 Np fission rate.
 (E)   Primary reference for half-life, gamma energy, and gamma emission probability is Ref ( 2 ) when data are available. For 103 Ru, data were not found in BIPM and the NuDAT/ENSDF data were used ( 3 , 4 ) .
 (F)   The sum of the half-lives for the mass A = 140 beta decay chain nuclides leading to 140 Ba is ~83.5 s. The 140 Ba half-life is 12.8 d. Thus, assuming that the cumulative fission product yield for 140 Ba can be considered to be attained within ten half-lives for this chain, the cumulative fission product yield for 140 Ba can be considered to represent the number of 140 Ba atoms that feed the transient equilibrium for 140 Ba- 140 La. A similar statement can be made for the 137 Cs- 137m Ba transient equilibrium where the sum of the half-lives for the mass A = 137 beta decay chain nuclides leading to 137 Cs is ~4.6 min, the 137m Ba half-life is 2.5545 min, and the 137 Cs half-life is 30.018 years.
 (A)   The IRDFF-II recommended fission yields are the recommended source. These values were adopted from the JEFF-3.3 radioactive decay data and fission yields sub-libraries ( 5 ) .
 (B)   All yield data given as a %; RC represents a cumulative yield; RI represents an independent yield.
 (C)   The neutron energy represents a generic “fast neutron” spectrum and has been characterized/documented in the JEFF 3.1.1 fission yield library as representing results for an average incident neutron energy of ~0.4 MeV.
 5.3.1   137 Cs- 137m Ba is chosen frequently for long irradiations. Radioactive products 134 Cs and 136 Cs may be present, which can interfere with the counting of the 0.661655 MeV 137 Cs- 137m Ba gamma ray (see Test Method E320 ).
 5.3.2   140 Ba- 140 La is chosen frequently for short irradiations (see Test Method E393 ).
 5.3.3   95 Zr can be counted directly, following chemical separation, or with its daughter 95 Nb, using a high-resolution gamma detector system.
 5.3.4   144 Ce is a high-yield fission product applicable to two to three-year irradiations.
 5.4  It is necessary to surround the 237 Np monitor with a thermal neutron absorber to minimize fission product production from trace quantities of fissionable nuclides in the 237 Np target and from 238 Np and 238 Pu from (n,γ) reactions in the 237 Np material. Assay of 238 Pu and 239 Pu concentration is recommended when a significant contribution is expected.
 5.4.1  Fission product production in a light-water reactor by neutron activation products 238 Np and 238 Pu has been calculated to be insignificant (1.2 %), compared to that from 237 Np(n,f), for an irradiation period of twelve years at a fast neutron ( E > 1 MeV) fluence rate of 1 × 10 11 cm −2 ·s −1 , provided the 237 Np is shielded from thermal neutrons (see Fig. 2 of Guide E844 ).
 5.4.2  Fission product production from photonuclear reactions, that is, (γ,f) reactions, while negligible near-power and research reactor cores, can be large for deep-water penetrations ( 6 ) .
 5.5  This dosimetry reaction is important in the area of reactor retrospective dosimetry ( 7 , 8 ) . Good agreement between neutron fluence measured by 237 Np fission and the 54 Fe(n,p) 54 Mn reaction has been demonstrated ( 9 , 10 ) . The reaction, 237 Np(n,f) F.P., is useful since it is responsive to a broader range of neutron energies than most threshold detectors.
 5.5.1   Fig. 1 shows the energy-dependent cross section for this dosimetry reaction. The figure shows that, while it is not strictly a threshold detector, because of its sensitivity in the greater than 0.1 MeV neutron energy range it can function as a detector with good sensitivity in the fast neutron region. In the fast fission 252 Cf spontaneous fission benchmark field, ~1 % of the 237 Np fission dosimeter response comes from neutrons with an energy less than 0.1 MeV. In the cavity of a fast burst 235 U reactor, ~5 % of the 237 Np fission dosimeter response comes from neutrons with an energy less than 0.1 MeV. In the cavity of a well-moderated pool-type research reactor, ~50 % of the fission response from the 237 Np(n,f) reaction comes from neutron energies less than 0.1 MeV. The importance of this low neutron energy sensitivity should be determined based on the application.
 5.6  The   237 Np fission neutron spectrum-averaged cross section in several benchmark neutron fields are given in Table 3 of Practice E261 . Sources for the latest recommended cross sections are given in Guide E1018 . In the case of the 237 Np(n,f)F.P. reaction, the recommended cross section source is the International Reactor Dosimetry and Fusion File (IRDFF-II) nuclear data library ( 11 ) . Fig. 1 compares the recommended IRDFF-II cross section with the EXFOR experimental data ( 12 , 13 ) .
 Scope
 1.1  This test method covers procedures for measuring reaction rates by assaying a fission product (F.P.) from the fission reaction 237 Np(n,f)F.P.
 1.2  The reaction is useful for measuring neutrons with energies from approximately 0.7 to 6 MeV and for irradiation times up to 90 years, provided that the analysis methods described in Practice E261 are followed. If dosimeters are analyzed after irradiation periods longer than 90 years, the information inferred about the fluence during irradiation periods more than 90 years before the end of the irradiation should not be relied upon without supporting data from dosimeters withdrawn earlier.
 1.3  Equivalent fission neutron fluence rates as defined in Practice E261 can be determined.
 1.4  Detailed procedures for other fast-neutron detectors are referenced in Practice E261 .
 1.5  The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
 1.6   This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
 1.7   This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
ASTM E705-25 PDF

ASTM E705-25 PDF

$36.00 $72.00