BS 1251-2015 PDF

BS 1251-2015 PDF

Open-fireplace components

$105.41 $210.82 -50%
Publisher
isbn 9780580578397
Product Code: BS 1251
Stock In Stock
Published: 03/31/2015
Number of Pages: 22
File Size: 1 file, 740 KB

Available Options

Product Description

Open-fireplace components

Publishing information: This British Standard is published by BSI Standards Limited, under licence from The British Standards Institution, and came into effect on 31 March 2015. It was prepared by Technical Committee RHE/28, Domestic solid mineral fuel appliances. A list of organizations represented on this committee can be obtained on request to its secretary. Supersession This British Standard supersedes BS 1251:1987, which is withdrawn.

Information about this document: The principal changes introduced by this revision are as follows. Mention of different materials currently used in the construction of fireplaces and their suitability. The minimum projection of the hearth of inset open fires has been decreased in accordance with the Building Regulations [1], [2] and [3]. Requirements are specified for mechanical fixings for cut stone and boxed section fireplace surrounds to secure them to chimney breasts.

Presentational conventions: The provisions of this standard are presented in roman (i.e. upright) type. Its requirements are expressed in sentences in which the principal auxiliary verb is “shall”. Commentary, explanation and general informative material is presented in smaller italic type, and does not constitute a normative element. It should be noted that many desirable properties of open-fireplace components cannot be specified objectively. However, attention is drawn to the notes in this standard and to BS 8303, which gives guidelines for their assembly.

Scope: This British Standard specifies requirements for components which, when assembled in accordance with BS 8303, form the setting for inset open fires of nominal sizes 400 mm and 450 mm (see Figure 1). Clause 3 specifies requirements for firebacks for inset open fires without boilers or underfloor air supply used with solid fuel. Clause 4 specifies requirements for prefabricated fireplace surrounds and hearths and excludes constructional hearths at floor level (see Figure 1). Clause 5 specifies requirements for precast, reinforced concrete throat-forming lintels, excluding those designed to form part of a complete appliance. NOTE 1 Lintels conforming to this British Standard are suitable for use as load-bearing supports for brickwork. NOTE 2 Requirements for fireguards are specified in BS 8423.

Contents:

  • Foreword
  • Scope
  • Annexes
  • Annex A (normative) Heat resistance test
  • Bibliography

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
BS 1251-2015 PDF

BS 1251-2015 PDF

$105.41 $210.82