13 A plugs, socket-outlets, adaptors and connection units-Rewirable and non-rewirable 13 A fused plugs. Specification
Publishing information: This part of BS 1363 is published by BSI Standards Limited, under licence from The British Standards Institution, and came into effect on 30 June 2023. It was prepared by Technical Committee PEL/23, Electrical accessories. A list of organizations represented on this committee can be obtained on request to the committee manager. Supersession This part of BS 1363 supersedes BS 1363‑1:2016+A1:2018 which remains current and will be withdrawn on 30 June 2026. Relationship with other publications BS 1363 is published in the following parts: Part 1: Rewirable and non-rewirable 13 A fused plugs – Specification; Part 2: 13 A switched and unswitched socket-outlets – Specification; Part 3: Adaptors – Specification; Part 4: 13 A fused connection units: switched and unswitched – Specification; Part 5: Fused conversion plugs – Specification.
Information about this document: This is a full revision of the document, and introduces the following principal changes: the Scope now covers operating frequencies from 50 Hz to 60 Hz; current carrying parts made of brass are required to have a minimum content of 58% copper; the overload test has been revised for rewirable and non-rewirable plugs. The numbering of figures within this standard remains as in the previous version; however, future revisions will implement consecutive numbering throughout. Annex J gives details of the annex renumbering from the 2016 editions of BS 1363, Part 1 to Part 5 to the 2023 editions. This publication can be withdrawn, revised, partially superseded or superseded. Information regarding the status of this publication can be found in the Standards Catalogue on the BSI website at bsigroup.com/standards, or by contacting the Customer Services team. Where websites and webpages have been cited, they are provided for ease of reference and are correct at the time of publication. The location of a webpage or website, or its contents, cannot be guaranteed.
Presentational conventions: The provisions of this standard are presented in roman (i.e. upright) type. Its requirements are expressed in sentences in which the principal auxiliary verb is “shall”. Commentary, explanation and general informative material is presented in smaller italic type, and does not constitute a normative element. Requirements in this standard are drafted in accordance with the Rules for the structure and drafting of UK standards:2022, subclause G.1.1, which states, “Requirements should be expressed IV © THE BRITISH STANDARDS INSTITUTION 2023 – ALL RIGHTS RESERVED using wording such as: ‘When tested as described in Annex A, the product shall ...’”. This means that only those products that are capable of passing the specified test will be deemed to conform to this standard. Where words have alternative spellings, the preferred spelling of the Shorter Oxford English Dictionary is used (e.g. “organization” rather than “organisation”).
Scope: This part of BS 1363 specifies requirements for 13 A fused plugs having insulating sleeves on line and neutral pins, for household, commercial and light industrial purposes, with particular reference to safety in normal use. The plugs are suitable for the connection of portable appliances, sound-vision equipment, luminaires, etc. in a.c. circuits only, operating at voltages not exceeding 250 V r.m.s. and frequencies from 50 Hz to 60 Hz. Additional requirements are included for plugs suitable for electric vehicle charging. Requirements are specified for plugs incorporating a fuse link conforming to BS 1362:1973+A3:2021. The plugs might be rewirable or non-rewirable complete with flexible cable. Categories of plugs are specified covering normal and rough use. Rewirable plugs are intended for use with flexible cables conforming to the relevant parts of BS EN 50525 (see Clause 2), having conductor cross‑sectional areas from 0.5 mm2 to 1.5 mm2 inclusive. See 20.1. Non-rewirable plugs are intended for use with flexible cables having conductor cross-sectional areas not exceeding 1.5 mm2. See 20.4. This standard also applies to non-rewirable 13 A plugs which have the earth pin replaced with a similarly dimensioned protrusion made of insulating material designated as an insulated shutter opening device (ISOD) designed to operate the shutter mechanism of socket-outlet conforming to A plug is mechanical by nature of construction. The product is therefore immune from electromagnetic interference. Plugs incorporating switches and indicator lamps are included within the scope of this part of BS 1363. Plugs incorporating electronic components detailed in Annex A are included within the scope of this part of BS 1363. Recommendations for plug in equipment incorporating BS 1363‑1 plug pins are given in Annex B.