Testing hardened concrete-Determination of the potential carbonation resistance of concrete. Accelerated carbonation method
Publishing information: This part of BS 1881 is published by BSI Standards Limited, under licence from The British Standards Institution, and came into effect on 30 June 2013. It was prepared by Technical Committee B/517, Concrete and related products. A list of organizations represented on this committee can be obtained on request to its secretary.
Information about this document: This part of BS 1881 is based on prTS12390-12, which received a negative vote. Consequently the CEN work item has been deleted. As this standard reflected UK experience with accelerated carbonation testing, it has been published as a British Standard with modifications to eliminate the various options. Relationship with other publications BS 1881 is published in the following parts: BS 1881-113, Method for making and curing no-fines cubes; BS 1881-119, Method for determination of compressive strength using portions of beams broken in flexure (equivalent cube method); BS 1881-122, Method for determination of water absorption; BS 1881-124, Methods for analysis of hardened concrete; BS 1881-125, Method for mixing and sampling fresh concrete in the laboratory; BS 1881-128, Method for analysis of fresh concrete; BS 1881-129, Method for the determination of density of partially compacted semi-dry fresh concrete; BS 1881-130, Method for temperature matched curing of concrete specimens; BS 1881-131, Methods for testing cement in a reference concrete; BS 1881-201, Guide to the use of non-destructive methods of test for hardened concrete; BS 1881-204, Recommendations on the use of electromagnetic covermeters; BS 1881-206, Recommendations for determination of strain in concrete; BS 1881-207, Recommendations for the assessment of concrete strength by near-to-surface tests; BS 1881-208, Recommendations for the initial surface absorption of concrete; BS 1881-209, Recommendations for the measurement of dynamic modulus of elasticity of concrete; DD 216, Determination of chloride content of fresh concrete.
Presentational conventions: The provisions of this standard are presented in roman (i.e. upright) type. Its requirements are expressed in sentences in which the principal auxiliary verb is “shall”. Commentary, explanation and general informative material is presented in smaller italic type, and does not constitute a normative element.
Scope: This part of BS 1881 describes a method for ranking the potential carbonation resistance of concrete using an accelerated carbonation test. NOTE 1 This test is an accelerated test because there is exposure to much higher than atmospheric levels of CO2 and is at a relative humidity conducive to a maximum rate of carbonation. NOTE 2 The test under reference conditions takes a minimum of 112 days comprising a minimum age of the specimen prior to conditioning of 28 days, a minimum conditioning period of 14 days and a minimum exposure to increased CO2 levels of 70 days. NOTE 3 The use of such test data in service-life modelling is still a matter of much academic debate and at present there is no consensus on an appropriate model. It is not a method for the determination of carbonation depths in existing concrete structures.
Contents:
- Foreword
- Introduction
- Scope
- Annexes
- Annex A (informative) Guidance on suitable storage chambers
- Bibliography