BS 476-22-1987 PDF

BS 476-22-1987 PDF

Fire tests on building materials and structures - Methods for determination of the fire resistance of non-loadbearing elements of construction - Incorporating Corrigenda Nos. 1 and 2

$139.70 $279.40 -50%
Publisher
isbn 9780539342833
Product Code: BS 476-22
Stock In Stock
Published: 12/31/2024
Number of Pages: 24
File Size: 1 file, 730 KB

Available Options

Product Description

Fire tests on building materials and structures - Methods for determination of the fire resistance of non-loadbearing elements of construction - Incorporating Corrigenda Nos. 1 and 2

Scope: This Part of BS 476 describes procedures for determining the fire resistance of non-loadbearing elements of building construction when subjected to the heating and pressure conditions specified in BS 476-20. This Part is applicable to vertical partitions, to fully insulated, partially insulated and uninsulated vertical doorsets and shutter assemblies (except fire dampers incorporated in ducts), to ceiling membranes, and to glazed elements. The methods described are appropriate to normal combinations of these elements. NOTE The titles of the publications referred to in this standard are listed on the inside back cover. 2 Definitions For the purposes of this Part of BS 476, the definitions given in BS 476-20 and BS 4422 apply, together with the following: 2.1 ceiling membrane a non-loadbearing element of a building construction designed to provide horizontal fire separation as distinct from protection to any floor or roof above 2.2 doorset an assembly (including any frame or guide) for the closing of permanent openings in separating elements. For the purposes of this standard, the term doorset includes shutter assemblies but excludes fire dampers for incorporation into ducts 2.3 partition a non-loadbearing element of a building construction designed to provide vertical fire separation when exposed to fire from one side NOTE The partition may incorporate either glazing or doors. 3 Test conditions The test conditions shall be as specified in 4 Apparatus The apparatus for the test shall be as specified in BS 476-20 except that the apparatus for the provision of loading and fixity specified in 6.2 and 6.3.2 of BS 476-20:1987 is not required. 5 Determination of the fire resistance of partitions 5.1 General This clause describes a method for the determination of the fire resistance of partitions and non-loadbearing walls providing vertical separation which are required to withstand exposure from fire from one or either side (see A.1.1). NOTE Loadbearing partitions or walls

Contents:

  • Foreword
  • Scope