BS 5250-2021 PDF

BS 5250-2021 PDF

Management of moisture in buildings. Code of practice

$220.98 $441.96 -50%
Publisher
isbn 9780539189759
Product Code: BS 5250
Stock In Stock
Published: 10/05/2021
Number of Pages: 178
File Size: 1 file, 9.2 MB

Available Options

Product Description

Management of moisture in buildings. Code of practice

Publishing information: This British Standard is published by BSI Standards Limited, under licence from The British Standards Institution, and came into effect on 31 July 2021. It was prepared by Subcommittee B/540/2, Building performance – Moisture, under the authority of Technical Committee B/540, Energy performance of materials, components and buildings. A list of organizations represented on these committees can be obtained on request to the committee manager. Supersession This British Standard supersedes BS 5250:2011+A1:2016, which is withdrawn.

Information about this document: This is a full revision of the standard, and introduces the following principal changes: guidance on moisture risk concerning problems other than just condensation has been added; a whole-building approach to moisture safe design, introduced in the BSI White Paper Moisture in buildings [1] is adopted, including prescriptive, modelling and principles based; approaches considering building context, coherence of design and detailing and interactions, capacity and in-service conditions have been added; a major revision of the content relating to floors (Clause 10), walls (Clause 11) and roofs (Clause 12) with particular emphasis on managing moisture risks in buildings undergoing energy saving measures; and a general update of other parts of the standard. This publication can be withdrawn, revised, partially superseded or superseded. Information regarding the status of this publication can be found in the Standards Catalogue on the BSI website at bsigroup.com/standards, or by contacting the Customer Services team. Where websites and webpages have been cited, they are provided for ease of reference and are correct at the time of publication. The location of a webpage or website, or its contents, cannot be guaranteed.

Use of this document: As a code of practice, this British Standard takes the form of recommendations and guidance. It is not to be quoted as if it were a specification. Users are expected to ensure that claims of compliance are not misleading. Users may substitute any of the recommendations in this British Standard with practices of equivalent or better outcome. Any user claiming compliance with this British Standard is expected to be able to justify any course of action that deviates from its recommendations. It has been assumed in the preparation of this British Standard that the execution of its provisions will be entrusted to appropriately qualified and experienced people, for whose use it has been produced.

Presentational conventions: The provisions of this standard are presented in roman (i.e. upright) type. Its recommendations are expressed in sentences in which the principal auxiliary verb is “should”. BRITISH STANDARD Commentary, explanation and general informative material is presented in smaller italic type, and does not constitute a normative element. The word “should” is used to express recommendations of this standard. The word “may” is used in the text to express permissibility, e.g. as an alternative to the primary recommendation of the clause. The word “can” is used to express possibility, e.g. a consequence of an action or an event. Notes and commentaries are provided throughout the text of this standard. Notes give references and additional information that are important but do not form part of the recommendations. Commentaries give background information. Where words have alternative spellings, the preferred spelling of The Shorter Oxford English Dictionary is used (e.g. “organization” rather than “organisation”).

Scope: This British Standard gives recommendations for the management of moisture in buildings using an integrated and pragmatic approach. This includes the management of moisture risk from interstitial and surface condensation, from too high or too low internal relative humidity, and from rain penetration or high levels of ground water. It covers all states of water as gas, liquid and solid, and the interactions between these states. It describes the principal sources of moisture in buildings, its transportation and deposition and provides recommendations and guidance on how to manage those risks during the assessment, design, construction and operation of buildings. This British Standard does not cover measures specifically dealing with flooding and escape of water. These are dealt with in BS 85500. This British Standard is intended for use by designers, builders and users of any class of building. This standard gives guidance on risks of all sorts from high moisture levels, whether in the building fabric or in indoor air, which can endanger the health and well‑being of building occupants and the integrity of the building fabric. This British Standard is relevant to buildings of all types, whatever their form, construction and occupancy, both new and existing, and both domestic and non-domestic, except for buildings used for storage at sub-zero temperatures.

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
BS 5250-2021 PDF

BS 5250-2021 PDF

$220.98 $441.96