BS 5864-2019 PDF

BS 5864-2019 PDF

Installation and maintenance of gas-fired ducted air heaters of rated heat input not exceeding 70 kW net (2nd and 3rd family gases). Specification

$204.47 $408.94 -50%
Publisher
isbn 9780539004229
Product Code: BS 5864
Stock In Stock
Published: 02/28/2019
Number of Pages: 58
File Size: 1 file, 1.8 MB

Available Options

Product Description

Installation and maintenance of gas-fired ducted air heaters of rated heat input not exceeding 70 kW net (2nd and 3rd family gases). Specification

Publishing information: This British Standard is published by BSI Standards Limited, under licence from The British Standards Institution, and came into effect on 28 February 2019. It was prepared by Technical Committee GSE/030, Gas installations (1st, 2nd and 3rd family gases). A list of organizations represented on this committee can be obtained on request to its secretary. Supersession This British Standard supersedes BS 5864:2010, which is withdrawn.

Information about this document: This is a full revision of the standard, and introduces the following principal changes: Annex B gives information about the connection options for condensate and combined pressure relief valve/condensate discharge. Annex C gives information on the procedure for inspecting a heat exchanger. Annex D gives information on the procedure for setting up the fan-assisted provision of combustion air.

Presentational conventions: The provisions of this standard are presented in roman (i.e. upright) type. Its requirements are expressed in sentences in which the principal auxiliary verb is “shall”. Commentary, explanation and general informative material is presented in smaller italic type, and does not constitute a normative element. Requirements in this standard are drafted in accordance with Rules for the structure and drafting of UK standards, subclause J.1.1, which states, “Requirements should be expressed using wording such as: ‘When tested as described in Annex A, the product shall ...’”. This means that only those products that are capable of passing the specified test will be deemed to conform to this standard.

Scope: This British Standard specifies requirements for the selection, installation and maintenance (see Note 1) of flued, gas-fired, ducted-air heaters of rated heat input not exceeding 70 kW, based on net calorific value, burning 2nd or 3rd family gases to heat one or more rooms or internal spaces in either domestic premises (see Note 2) or commercial premises. It is applicable to warm air heaters that incorporate a fan to circulate the warm air. It is also applicable to combined air heater/circulator installations and to the servicing and maintenance of heaters that distribute warm air by natural convection (see Annex A). It is not applicable to gas installations in towed or motorized leisure accommodation vehicles. NOTE 1 For the purposes of this British Standard, installation includes design, inspection and commissioning. It is recognized that each of these tasks can be performed by the same person. NOTE 2 As well as normally constructed dwellings, domestic premises include any permanently sited leisure accommodation vehicles, residential park homes and permanently moored boats. NOTE 3 For the purposes of this British Standard, heat input is expressed in terms of the net calorific values (CV), unless otherwise stated. The ratio of gross CV (Hs) to net CV (Hi) heat input is approximately 1.11:1 for natural gas, 1.09:1 for propane, and 1.08:1 for butane. NOTE 4 It is essential that persons carrying out the installation of any gas appliance be competent to do so.

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
BS 5864-2019 PDF

BS 5864-2019 PDF

$204.47 $408.94