BS 7346-7-2013 PDF

BS 7346-7-2013 PDF

Components for smoke and heat control systems-Code of practice on functional recommendations and calculation methods for smoke and heat control systems for covered car parks

$194.31 $388.62 -50%
Publisher
isbn 9780580792052
Product Code: BS 7346-7
Stock In Stock
Published: 08/31/2013
Number of Pages: 48
File Size: 1 file, 3.4 MB

Available Options

Product Description

Components for smoke and heat control systems-Code of practice on functional recommendations and calculation methods for smoke and heat control systems for covered car parks

Publishing information: This part of BS 7346 is published by BSI Standards Limited, under licence from The British Standards Institution, and came into effect on 31 August 2013. It was prepared by Technical Committee FSH/25, Smoke, heat control systems and components. A list of organizations represented on this committee can be obtained on request to its secretary. Supersession This part of BS 7346 supersedes BS 7346-7:2006, which is withdrawn. Relationship with other publications BS 7346 is published in the following parts: Part 4: Functional recommendations and calculation methods for smoke and heat ventilation systems, employing steady-state design fires – Code of practice; Part 5: Functional recommendations and calculation methods for smoke and heat ventilation systems, employing time-dependent design fires – Code of practice; Part 7: Code of practice on functional recommendations and calculation methods for smoke and heat control systems for covered car parks.

Information about this document: This is a full revision of the standard, and introduces the following principal changes: car parks with stacker systems; reference to guidance on the ventilation of loading bays and coach parks.

Use of this document: As a code of practice, this part of BS 7346 takes the form of guidance and recommendations. It should not be quoted as if it were a specification and particular care should be taken to ensure that claims of compliance are not misleading. Any user claiming compliance with this part of BS 7346 is expected to be able to justify any course of action that deviates from its recommendations.

Presentational conventions: The provisions of this standard are presented in roman (i.e. upright) type. Its recommendations are expressed in sentences in which the principal auxiliary verb is “should”. Commentary, explanation and general informative material is presented in smaller italic type, and does not constitute a normative element.

Scope: This part of BS 7346 gives guidance on functional recommendations and calculation methods for smoke and heat control systems for covered parking areas for cars and light commercial vehicles. NOTE 1 It is assumed that cars powered by fuels other than petrol or diesel will have a fire performance similar to vehicles powered by petrol or diesel. This assumption might be revised in a future edition of this standard if further information suggests it is necessary. It is intended for system designers, installers of systems, regulatory authorities, for example building control officers and fire safety officers, and those who manage the fire safety of car parks. It gives recommendations for systems designed for open-sided car parks and for enclosed car parks. It covers: systems intended to protect means of escape for occupants of the car park or the building housing the car park; systems intended to assist active fire-fighting operations; and systems intended to provide smoke clearance following suppression of a fire. It includes recommendations for natural open-sided ventilation and for ducted mechanical ventilation. It includes guidance on performance-based smoke control using impulse ventilation systems and smoke and heat exhaust ventilation systems (SHEVS). Time-dependent and steady-state design methods are included as appropriate for each smoke control approach. Control of vehicle pollutant emissions is included where it influences the optimization of smoke control. Following the BRE fire tests on car stacker systems, it also includes recommendations for fire sizes and fire suppression in these types of installations. Smoke and heat control systems for loading bays and coach parks are not covered by this standard. NOTE 2 Guidance on loading bays and coach parks can be found in the FETA publication, Design of smoke ventilation systems for loading bays and coach parks – a guide for system designers [5].

Contents:

  • Foreword
  • Introduction
  • Scope
  • Annexes
  • Annex A (normative) Smoke control duct sections and smoke control
  • Annex B (normative) Computer-based models
  • Annex C (informative) Lighting, signage, public address and voice alarm
  • Bibliography