LV and MV polymeric insulated cables for use by distribution and generation utilities-Distribution cables of rated voltage 0.6/1 (1.2) kV. Specification-XLPE insulated, copper wire waveform concentric cables with solid aluminium or stranded copper conductors (Implementation of HD 603)
Publishing information: This section of BS 7870‑3 is published by BSI Standards Limited, under licence from The British Standards Institution and came into effect on 31 December 2023. It was prepared by Subcommittee GEL/20/16, Medium/High voltage cables, under the authority of Technical Committee GEL/20, Electric cables. A list of organizations represented on these committees can be obtained on request to the committee manager. Supersession This section of BS 7870‑3 supersedes BS 7870‑3.40:2011, which is withdrawn. Relationship with other publications BS 7870 implements the nationally applicable parts of Harmonization Documents HD 603, HD 605, HD 620, HD 626 and HD 627 published by the European Committee for Electrotechnical Standardization (CENELEC) in accordance with the decision of the CENELEC Technical Board. BS 7870 applies to cables for fixed installations having a rated voltage U0/U up to and including 19/33 kV. BS 7870 is published as a series of separate parts and sections, as listed in This section of BS 7870‑3 specifies a range of XLPE insulated, copper wire waveform concentric cables with solid aluminium or stranded copper conductors and is to be read in conjunction with BS 7870‑1:2011+A1:2022 and BS 7870‑2:2022. A general guide to use for the types of cable specified in BS 7870 is given in BS 7870‑1:2011+A1:2022 and specific details for the types of cable specified in this section of BS 7870 are given in Annex A.
Information about this document: This is a full revision of the document, which brings it up to date in accordance with current practice in the industry. This publication can be withdrawn, revised, partially superseded or superseded. Information regarding the status of this publication can be found in the Standards Catalogue on the BSI website at bsigroup.com/standards, or by contacting the Customer Services team. Where websites and webpages have been cited, they are provided for ease of reference and are correct at the time of publication. The location of a webpage or website, or its contents, cannot be guaranteed. Hazard warnings WARNING. This British Standard calls for the use of substances and/or procedures that can be injurious to health if adequate precautions are not taken. It refers only to technical suitability and does not absolve the user from legal obligations relating to health and safety at any stage.
Use of this document: It has been assumed in the preparation of this British Standard that the execution of its provisions will be entrusted to appropriately qualified and experienced people, for whose use it has been produced. BRITISH STANDARD
Presentational conventions: The provisions of this document are presented in roman (i.e. upright) type. Its requirements are expressed in sentences in which the principal auxiliary verb is “shall”. Commentary, explanation and general informative material is presented in smaller italic type, and does not constitute a normative element. Where words have alternative spellings, the preferred spelling of the Shorter Oxford English Dictionary is used (e.g. “organization” rather than “organisation”).
Scope: This section of BS 7870 specifies requirements for the construction, dimensions and mechanical and electrical properties of copper wire waveform cables with solid aluminium or stranded copper conductors, XLPE insulation and PVC oversheath having a rated voltage of 0.6/1(1.2) kV. It specifies requirements for the following types of cable: a) 3-core, 3-phase, with a concentric neutral/earth conductor of copper wires bedded on a single rubber layer; and b) 4-core, 3-phase and a separate neutral, with a concentric earth conductor of copper wires bedded on a single rubber layer. This section of BS 7870 is applicable to cables designed for a maximum continuous conductor operating temperature of 80 °C and for a maximum short circuit conductor temperature of 250 °C. NOTE Guidance on type testing is given in Annex B.