Method for calibration and classification of torque measuring devices

Publishing information: This British Standard is published by BSI Standards Limited, under licence from The British Standards Institution, and came into effect on 31 August 2017. It was prepared by Panel ISE/101/1/2, Torque measuring and testing, under the authority of Subcommittee ISE/101/1, Uniaxial testing, and Technical Committee ISE/101, Test methods for metals. A list of organizations represented on these committees can be obtained on request to their secretary. Supersession This British Standard supersedes BS 7882:2008, which is withdrawn.

Information about this document: This revision introduces the relative measurement uncertainty interval, the range in which the expected error is likely to lie, calculated as the sum of the absolute relative deviation and the expanded uncertainty. Some of the values in Table B.4 and Table B.7 are given to 8 decimal places, to allow users to check the data manually against these and the other tables in Annex B, and to eliminate rounding errors. It is not necessary to report at this level.

Presentational conventions: The provisions of this standard are presented in roman (i.e. upright) type. Its methods are expressed as a set of instructions, a description, or in sentences in which the principal auxiliary verb is “shall”. Commentary, explanation and general informative material is presented in smaller italic type, and does not constitute a normative element.

Scope: Terms, definitions, abbreviations and symbols Preparation for calibration 3.1 Reference standard Table 1 — Uncertainty of calibration torques 3.2 Condition and identification of a torque measuring device 3.3 Resolution of the indicator 3.4 Lower limit of calibration, Tmin 3.5 Number of calibration orientations (see Annex A) Preliminary procedure 4.1 Alignment 4.2 Temperature considerations 4.3 Instrumentation set-up 4.4 Preloading procedure Calibration procedure 5.1 Selection of calibration torques 5.2 Application of calibration torques Calculation of results 6.1 Determination of deflection, d 6.2 Determination of relative repeatability, R1 6.3 Determination of relative reproducibility, R2 6.4 Determination of relative errors of interpolation, Eit and Eitd 6.5 Determination of relative residual deflection, R0 6.6 Determination of relative reversibility, R3 6.7 Determination of relative errors of indication, Ei and Eid 6.8 Determination of uncertainty of measurement and relative measurement uncertainty interval Classification of torque measuring devices 7.1 General 7.2 Determination of a classification and its range Table 2 — Criteria for classification of torque measuring devices Calibration certificate Annex A (informative) Orientation diagrams Figure A.1 — Example of preloading and calibration sequences for a torque measuring device with round shaft drives, six incremental and decremental torques, classes 0.05 to 5.0 Annex B (normative) Method example of determining uncertainty of the calibration results of the torque measuring device Table B.1 — Summary of worked examples Table B.2 — Worked example in torque units: 100 N·m torque measuring device clockwise torque, incremental series only Table B.2 — Worked example in torque units: 100 N·m torque measuring device clockwise torque, incremental series only (continued) Table B.2 — Worked example in torque units: 100 N·m torque measuring device clockwise torque, incremental series only (continued) Table B.3 — Uncertai