Guide for the use of electronic portable combustion gas analysers for the measurement of carbon monoxide in dwellings and the combustion performance of domestic gas-fired appliances
Publishing information: This British Standard is published by BSI Standards Limited, under licence from The British Standards Institution, and came into effect on 28 February 2015. It was prepared by Panel GSE/30/‑/21, Gas Analysers, under the authority of Technical Committee GSE/30, Gas installations (1st, 2nd and 3rd family gases). A list of organizations represented on this committee can be obtained on request to its secretary. Supersession This British Standard supersedes BS 7967-1:2005, BS 7967-2:2005, BS 7967‑3:2005 and BS 7967‑4:2007, which are withdrawn. BS 7967-5, which covers the use of electronic portable combustion gas analysers in non-domestic premises, remains current.
Information about this document: This British Standard is intended to be used in conjunction with the gas appliance commissioning, servicing and maintenance instructions and the Gas Industry Unsafe Situations Procedure [1]. Its purpose is to provide: a) information that is intended to assist gas operatives (see 3.12) in considering all the relevant issues and circumstances relating to the identification of sources of fumes and smells and the cause of carbon monoxide (CO) detector activation, or when spillage/leakage of combustion products is suspected or encountered from an unknown source; b) information on combustion performance characteristics of a range of gas appliance types and the levels at which remedial action is to be taken; c) advice on the actions to be taken when elevated concentrations of carbon monoxide (CO) are identified in dwellings; d) the appropriate method(s) for using an electronic portable combustion gas analyser to: check the combustion performance of gas appliances; measure the concentrations of CO within a dwelling and, in certain circumstances (see Clause 1, Notes 4 and 5, and Commentary on 8.1), detect the presence of carbon dioxide (CO2); and identify sources of the CO spillage/leakage; e) good practice guidance on the use of electronic portable combustion gas analysers as part of a servicing and/or maintenance procedure for gas appliances in dwellings; and NOTE Electronic portable combustion gas analysers are often referred to colloquially as “flue gas analysers” (FGAs). f) guidance on the use of combustion gas analysis as a diagnostic tool to assist a gas operative to confirm the safe and efficient functioning of a gas appliance when work has been done on that appliance. This standard: 1) is not intended to be an exhaustive step-by-step procedure, and gas operatives need to hold an appropriate certificate of gas safety competence (see Clause 4) and use sound judgement in deciding how best to respond to individual cases. Where a gas operative is carrying out routine servicing or repair work on an appliance, testing could indicate a spillage/leakage problem. In such cases, there is no obligation to carry out all the considerations, inspections and tests described in this guidance as the gas operative has personally identified the issue and the source of spillage/leakage is known. Only those subclauses in this standard that are concerned with the particular appliance involved would be relevant in such circumstances; 2) supplements gas appliance manufacturers’ servicing requirements through a generic approach to servicing and maintenance activity and by identifying situations where combustion gas analysis cannot be deployed or is not appropriate; 3) does not intend that a combustion gas analysis be used as a substitute for normal servicing and/or maintenance carried out in accordance with the gas appliance instructions; 4) recognizes that it is important that the gas appliance instructions are followed; and 5) continues to use the term “flue” in its traditional UK sense, as any structure used to conduct the combustion products from an appliance to the outside air; as opposed to the European approach in standards, where a “flue” is only the passageway in the structure through which the combustion products flow. The documents available as downloads from the sites referenced throughout the document were last accessed on 10 February 2015.
Use of this document: As a guide, this British Standard takes the form of guidance and recommendations. It should not be quoted as if it were a specification or a code of practice and claims of compliance cannot be made to it. It has been assumed in the preparation of this British Standard that the execution of its provisions will be entrusted to competent people (see Clause 4 for information on competence), for whose use it has been produced.
Presentational conventions: The guidance in this standard is presented in roman (i.e. upright) type. Any recommendations are expressed in sentences in which the principal auxiliary verb is “should”. The word “may” is used in the text to express permissibility, e.g. as an alternative to the primary recommendation of the clause. The word “can” is used to express possibility, e.g. a consequence of an action or an event. Commentary, explanation and general informative material is presented in smaller italic type, and does not constitute a normative element. Notes give references and additional information that are important but do not form part of the recommendations. Commentaries give background information.