Design and installation of natural stone cladding and lining-Internal cladding and lining. Code of practice

$220.98 $441.96 -50%
Publisher
isbn 9780539190946
Product Code: BS 8298-5
Stock In Stock
Published: 06/29/2023
Number of Pages: 86
File Size: 1 file, 4.7 MB

Available Options

Product Description

Design and installation of natural stone cladding and lining-Internal cladding and lining. Code of practice

Publishing information: This part of BS 8298 is published by BSI Standards Limited, under licence from The British Standards Institution, and came into effect on 30 June 2023. It was prepared by Technical Committee B/545, Natural stone. A list of organizations represented on this committee can be obtained on request to the committee manager. Supersession This part of BS 8298 supersedes BS 8298:1994 and partially supersedes BS 8298‑1:2010, which are withdrawn. Relationship with other publications BS 8298 is published in the following parts: Part 2: Traditional handset external cladding – Code of practice; Part 3: Stone‑faced pre‑cast concrete cladding systems – Code of practice; Part 4: Stone cladding on rainscreen support systems – Code of practice; and Part 5: Traditional handset internal cladding – Code of practice.

Information about this document: To provide more consistency with other material design standards, it is the long-term goal for the partial safety factors presented in the British Standard to be derived from a reliability-based analysis in accordance with the principles of BS EN 1990:2020+A1:2005, Annex D. However, the values presented in this edition are derived from industry experience and a historical precedent of conformity and not a reliability-based analysis. This publication can be withdrawn, revised, partially superseded or superseded. Information regarding the status of this publication can be found in the Standards Catalogue on the BSI website at bsigroup.com/standards, or by contacting the Customer Services team. Where websites and webpages have been cited, they are provided for ease of reference and are correct at the time of publication. The location of a webpage or website, or its contents, cannot be guaranteed.

Use of this document: As a code of practice, this part of BS 8298 takes the form of guidance and recommendations. It is not to be quoted as if it were a specification. Users are expected to ensure that claims of compliance are not misleading. It has been assumed in the preparation of this part of BS 8298 that the execution of its provisions will be entrusted to appropriately qualified and experienced people, for whose use it has been produced. Users may substitute any of the recommendations in this part of BS 8298 with practices of equivalent or better outcome. Any user claiming compliance with this part of BS 8298 is expected to be able to justify any course of action that deviates from its recommendations.

Presentational conventions: The provisions of this standard are presented in roman (i.e. upright) type. Its recommendations are expressed in sentences in which the principal auxiliary verb is “should”. BRITISH STANDARD Commentary, explanation and general informative material is presented in smaller italic type, and does not constitute a normative element. The word “should” is used to express recommendations of this standard. The word “may” is used in the text to express permissibility, e.g. as an alternative to the primary recommendation of the clause. The word “can” is used to express possibility, e.g. a consequence of an action or an event. Notes and commentaries are provided throughout the text of this standard. Notes give references and additional information that are important but do not form part of the recommendations. Commentaries give background information. Where words have alternative spellings, the preferred spelling of the Shorter Oxford English Dictionary is used (e.g. “organization” rather than “organisation”).

Scope: This part of BS 8298 gives recommendations for the design, installation and maintenance of internal cladding and lining of natural stone held directly to a structural background by fixings with or without adhesive. It is applicable for both commercial and residential locations. It covers four categories of construction build up: a) internal cladding ≥20 mm thick, with a cavity, supported at each floor level, mechanically supported and restrained; b) internal lining ≤2.4 m height, ≥20 mm thick (e.g. ≥600 mm × 600 mm to 2 400 mm × 600 mm) supported at floor level, stack-bonded, on adhesive, mechanically restrained to the substrate; c) internal lining ≤2.4 m height, ≥12 mm to ≤20 mm (e.g. ≤600 mm × 600 mm), supported at floor level, stack-bonded, on adhesive, mechanically restrained to the substrate; and d) ceilings, soffits and sloping surfaces with a cavity mechanically supported and restrained. Stone held only by adhesion is not included. It covers: 1) the sampling of stone for testing and production control testing (PCT); 2) the provisions necessary for cladding and lining to perform their function satisfactorily; and 3) the materials and methods most frequently used for stonework. This document is not applicable to seismic loading or enhanced security scenarios (such as blast). NOTE Different cladding methods are covered in the other parts of BS 8298 (see Foreword). This standard excludes composite stone slabs, such as honeycomb-backed stone, and open internal courtyards.