BS 1139-6-2022 w/corrigendum PDF

BS 1139-6-2022 w/corrigendum PDF

Metal scaffolding - Prefabricated tower scaffolds outside the scope of BS EN 1004-1, but utilizing components from such systems. Specification

$172.72 $345.44 -50%
Publisher
isbn 9780539227802
Product Code: BS 1139-6:2022 w/corrigendum
Stock In Stock
Published: 07/31/2022
Number of Pages: 42
File Size: 1 file, 1.3 MB

Available Options

Product Description

Metal scaffolding - Prefabricated tower scaffolds outside the scope of BS EN 1004-1, but utilizing components from such systems. Specification

Publishing information: This part of BS 1139 is published by BSI Standards Limited, under licence from The British Standards Institution, and came into effect on 31 January 2022. It was prepared by Subcommittee B/514/24, Access towers, under the authority of Technical Committee B/514, Access and support equipment. A list of organizations represented on this committee can be obtained on request to the committee manager. Supersession This part of BS 1139 supersedes BS 1139‑6:2014, which is withdrawn. Relationship with other publications BS 1139, Metal scaffolding, was published in six parts: Part 1.1: Tubes - Specification for steel tube (superseded by BS EN 39:2001); Part 1.2: Tubes - Specification for aluminium tube; Part 2.1: Couplers - Specification for steel couplers, loose spigots and base-plates for use in working scaffolds and falsework made of steel tubes (superseded by BS EN 74-1:2005); Part 3: Specification for prefabricated mobile access and working towers (superseded by Part 4: Specification for prefabricated steel splitheads and trestles; Part 5: Specification for materials, dimensions, design loads and safety requirements for service and working scaffolds made of prefabricated elements (superseded by BS EN 12810-1:2003); Part 6: Specification for prefabricated tower scaffolds outside the scope of BS EN 1004, but utilizing components from such systems. This part of BS 1139 should be read in conjunction with, and is complementary to, BS EN 1004‑1, Mobile access and working towers made of prefabricated elements — Materials, dimensions, design loads, safety and performance requirements.

Information about this document: Text introduced or altered by Corrigendum No. 1 is indicated in the text by tags . Minor editorial corrections are not tagged. This publication can be withdrawn, revised, partially superseded or superseded. Information regarding the status of this publication can be found in the Standards Catalogue on the BSI website at bsigroup.com/standards, or by contacting the Customer Services team. Where websites and webpages have been cited, they are provided for ease of reference and are correct at the time of publication. The location of a webpage or website, or its contents, cannot be guaranteed.

Presentational conventions: The provisions of this standard are presented in roman (i.e. upright) type. Its requirements are expressed in sentences in which the principal auxiliary verb is “shall”. Commentary, explanation and general informative material is presented in smaller italic type, and does not constitute a normative element. BRITISH STANDARD  Where words have alternative spellings, the preferred spelling of the Shorter Oxford English Dictionary is used (e.g. “organization” rather than “organisation”).

Scope: This part of BS 1139 specifies requirements for the structural design of prefabricated tower scaffolds utilizing components from mobile access and working towers specified in BS EN 1004‑1 but in configurations that are outside of the scope of that standard. These configurations include: a) high level tower scaffolds outside the maximum height limits of BS EN 1004‑1; b) tower scaffolds with more than one working platform at one time; c) large deck tower scaffolds; d) linked tower scaffolds; e) cantilever tower scaffolds; f) stepped tower scaffolds; g) tower scaffolds used as a means of access to another place; h) non-mobile towers built on base plates instead of castors; and i) tower scaffolds subject to wind loads greater than 0.1 kN/m2. NOTE Towers with wind loads up to 0.1 kN/m2 are specified in BS EN 1004‑1. Where a prefabricated tower scaffold might be subject to wind in excess of 0.1 kN/m2, and it cannot be dismantled or moved to avoid these winds, suitable wind design criteria can be found in this British Standard. This British Standard does not cover prefabricated tower scaffolds using guys as a method of stabilization. This British Standard does not cover prefabricated towers intended to be lifted.

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
BS 1139-6-2022 w/corrigendum PDF

BS 1139-6-2022 w/corrigendum PDF

$172.72 $345.44