Fire protection installations and equipment on premises-Guide for selection, use and application of fixed firefighting systems and other types of fire equipment
Publishing information: This part of BS 5306‑0 is published by BSI Standards Limited, under licence from The British Standards Institution, and came into effect on 31 August 2020. It was prepared by Technical Committee FSH/18, Fixed fire fighting systems. A list of organizations represented on this committees can be obtained on request to the committee manager. Supersession This part of BS 5306 supersedes BS 5306‑0:2011, which is withdrawn. Relationship with other publications This part of BS 5306 serves to introduce the subsequent parts of BS 5306 and references other standards as listed below and detailed in the Bibliography, each of which gives requirements or recommendations for the application of a particular type of firefighting system, discharging a particular firefighting medium. Taken together, the various parts of BS 5306 and other British Standards are intended to cover all the main types of firefighting media and systems for buildings in current use, and therefore form a comprehensive guide to all aspects of the subject. The subsequent parts of BS 5306 are as follows: Part 1: Hose reels and foam inlets; Part 3: Commissioning and maintenance of portable fire extinguishers – Code of practice; Part 4: Specification for carbon dioxide systems; Part 5: Halon systems1): Section 5.1: Specification for Halon 1301 total flooding systems; Section 5.2: Halon 1211 total flooding systems; Part 8: Selection and installation of portable fire extinguishers – Code of practice; Part 9: Recharging of portable fire extinguishers – Code of practice; Part 10: Colour coding to indicate the extinguishing medium contained in portable fire extinguishers – Code of practice. The following parts of BS 5306 have been superseded: Part 2: Specification for sprinkler systems (superseded by BS EN 12845, Fixed firefighting systems – Automatic sprinkler systems – Design, installation and maintenance); Part 6: Foam systems (superseded by BS EN 13565‑2, Fixed firefighting systems – Foam systems – Part 2: Design, construction and maintenance): Section 6.1: Specification for low expansion foam systems; Section 6.2: Specification for medium and high expansion foam systems; Part 7: Specification for powder systems (superseded by BS EN 12416‑2, Fixed firefighting systems – Powder systems – Part 2: Design, construction and maintenance). Other related standards are detailed in Clause 14. 1) Systems that can be used as an alternative to halon are covered by the BS EN 15004 series. BRITISH STANDARD
Information about this document: The aim of this part of BS 5306 is to aid selection of the appropriate firefighting medium and type of system or equipment by describing the characteristics and most suitable applications of each. Consideration has been given to the impact of firefighting media, including toxicity to people, effect of discharge on visibility, and danger of use on electrical equipment, in addition to factors such as monitoring, testing, maintenance and user responsibility. More detailed consideration of systems and equipment, including safety precautions, is given in the subsequent parts of BS 5306 and other British Standards. During the preparation of this part of BS 5306 it was suggested by some commentators that the advice in Table 1 appears to be focused on the use of sprinklers as a first priority. The Technical Committee responsible for the preparation of this part of BS 5306 understands this possible perception. However, its intent is not to promote the use of sprinklers to the exclusion of other types of system. It is an undeniable fact that the lengthy international experience of sprinkler systems (since the 1880s) has generated a substantial body of practical experience, effective loss prevention experience, reliability data and knowhow which underpin and offer significant assurance upon the level of performance of the most widely used means of automatic fire suppression. This part of BS 5306 does not advocate that sprinkler systems be specified to the exclusion of other types of systems, rather it recognizes that sprinklers are proven to be suitable and dependable in more applications and occupancies than other types of system. This is reflected in Table 1 and Table 2. None of the recommendations or guidance in this standard are to be taken as precluding the provision of manual means of fighting fire or as obviating the necessity to notify the fire and rescue service in the event of a fire. The International System of Units (SI) (see BS EN ISO 80000‑1) is followed in this part of BS 5306, except for units of pressure, which are expressed in bar2). Water discharge densities are expressed as rainfall at floor level, in mm/min. This publication can be withdrawn, revised, partially superseded or superseded. Information regarding the status of this publication can be found in the Standards Catalogue on the BSI website at bsigroup.com/standards, or by contacting the Customer Services team. Where websites and webpages have been cited, they are provided for ease of reference and are correct at the time of publication. The location of a webpage or website, or its contents, cannot be guaranteed.
Use of this document: As a guide, this part of BS 5306 takes the form of guidance and recommendations. It should not be quoted as if it were a specification or a code of practice.
Presentational conventions: The guidance in this standard is presented in roman (i.e. upright) type. Any recommendations are expressed in sentences in which the principal auxiliary verb is “should”. Commentary, explanation and general informative material is presented in smaller italic type, and does not constitute a normative element. Where words have alternative spellings, the preferred spelling of the Shorter Oxford English Dictionary is used (e.g. “organization” rather than “organisation”). 2) 1 bar = 105 N/m2 = 100 kPa. iv © THE BRITISH STANDARDS INSTITUTION 2020 – ALL RIGHTS RESERVED