BS 5410-2-2018 PDF

BS 5410-2-2018 PDF

Code of practice for liquid fuel firing-Non-domestic installations

$220.98 $441.96 -50%
Publisher
isbn 9780580964114
Product Code: BS 5410-2
Stock In Stock
Published: 04/30/2018
Number of Pages: 94
File Size: 1 file, 3.3 MB

Available Options

Product Description

Code of practice for liquid fuel firing-Non-domestic installations

Publishing information: This part of BS 5410 is published by BSI Standards Limited under licence from The British Standards Institution and came into effect on 30 April 2018. It was prepared by Technical Committee RHE/13, Oil burning equipment. A list of organizations represented on this committee can be obtained on request to its secretary. Supersession This part of BS 5410 supersedes BS 5410‑2:2013, which is withdrawn. Relationship with other publications BS 5410 is published in three parts as follows: Part 1: Installations for space heating and hot water supply purposes for domestic buildings1 Part 2: Installations providing space heating, hot water and steam supply services to non- domestic buildings Part 3: Installations for furnaces, kilns, ovens, oil-fuelled standby generators and other industrial purposes. Hazard warnings WARNING. Decommissioning and disposal of liquid fuel storage tanks The decommissioning and disposal of liquid fuel storage tanks can become necessary as part of the maintenance cycle of a liquid fuelled system. This is not covered in this British Standard. It is a very hazardous procedure, and it is imperative that it is only undertaken by specialist operatives who have the right equipment, expertise and insurance. Building owners should never attempt to cut up old liquid fuel storage tanks themselves. NOTE 1 Attention is drawn to the Construction (Design and Management) Regulations 2007 [1], which class such work as a “demolition project”. NOTE 2 Detailed guidance on decommissioning and disposal of liquid fuel storage tanks is given in OFTEC Technical Book 3 [2]. NOTE 3 Attention is drawn to The Dangerous Substances and Explosive Atmospheres Regulations 2002 [3] and the need to risk assess the selection of equipment to ensure safety in use and maintenance operations.

Use of this document: As a code of practice, this part of BS 5410 takes the form of guidance and recommendations. It should not be quoted as if it were a specification and particular care should be taken to ensure that claims of compliance are not misleading. Any user claiming compliance with this part of BS 5410 is expected to be able to justify any course of action that deviates from its recommendations. It has been assumed in the preparation of this British Standard that the execution of its provisions will be entrusted to appropriately qualified and experienced people, for whose use it has been produced. BS 5410-1 is currently being revised and is due to be published before the end of 2018. iv © THE BRITISH STANDARDS INSTITUTION 2018 – ALL RIGHTS RESERVED The provisions of this standard are presented in roman (i.e. upright) type. Its recommendations are expressed in sentences in which the principal auxiliary verb is “should”. Commentary, explanation and general informative material is presented in smaller italic type, and does not constitute a normative element. Where words have alternative spellings, the preferred spelling of the Shorter Oxford English Dictionary is used (e.g. “organization” rather than “organisation”).

Scope: This part of BS 5410 gives recommendations and guidance on the design, installation, commissioning and maintenance of liquid fuel firing installations for heating, hot water and steam supply services in non-domestic buildings. This also includes buildings containing multiple separate dwellings which are all served by a single heating and hot water system and buildings where public assembly, entertainment or hospitality take place. This part of BS 5410 is applicable to installations burning liquid fuel conforming to BS 2869, and other equivalent fuels, including biofuels, for example, those containing fatty acid methyl esters (FAME) conforming to BS EN 14214, and blends thereof. This British Standard covers the provision of new installations and also gives guidance on the modernizing of existing installations. This British Standard also gives recommendations and guidance on the selection and installation of liquid fuel storage tanks associated with these installations. This part of BS 5410 is applicable to the liquid fuel firing equipment forming part of a multi-fuel installation in which liquid fuel is not burnt simultaneously with any other fuel. It is not applicable to liquid fuelled systems for marine installations. This British Standard is intended for use by designers, specifiers, installers and building owners.

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
BS 5410-2-2018 PDF

BS 5410-2-2018 PDF

$220.98 $441.96