BS 5440-1-2023 PDF

BS 5440-1-2023 PDF

Chimneys, flue pipes and ventilation for gas appliances of rated input not exceeding 70 kW net (1st, 2nd and 3rd family gases)-Design, installation, commissioning and maintenance of chimneys. Specification

$220.98 $441.96 -50%
Publisher
isbn 9780539251678
Product Code: BS 5440-1
Stock In Stock
Published: 12/12/2023
Number of Pages: 104
File Size: 1 file, 4.4 MB

Available Options

Product Description

Chimneys, flue pipes and ventilation for gas appliances of rated input not exceeding 70 kW net (1st, 2nd and 3rd family gases)-Design, installation, commissioning and maintenance of chimneys. Specification

Publishing information: This part of BS 5440 is published by BSI Standards Limited, under licence from The British Standards Institution, and came into effect on 31 December 2023. It was prepared by Technical Committee GSE/30, Gas installations (1st, 2nd and 3rd family gases). A list of organizations represented on this committee can be obtained on request to the committee manager. Supersession This part of BS 5440 supersedes BS 5440‑1:2008, which is withdrawn. Relationship with other publications BS 5440 is published in the following parts: Part 1: Design, installation, commissioning and maintenance of chimneys – Specification; Part 2: Design, installation, commissioning and maintenance of chimneys – Specification.

Information about this document: This is a full revision of the document, and introduces the following principal changes: a) redefined chimney concepts and adopted common terminology consistent with the range of products used across the whole European Community; b) aligned with European Standards, (the general requirements for which are given in BS EN 1443) where a chimney is treated as a structure containing a flue (the passageway) and might include a liner (inner wall), insulation and an outer wall. The common terminology in UK industry, which has regarded a chimney as a masonry structure generally associated with solid fuel appliances, has been superseded. Attention is drawn to the definitions for chimney (3.9), connecting flue pipe (3.16), flue (3.27) and flue liner (3.30), air supply duct (3.1) and room-sealed chimney configuration (3.48); c) updated in line with recent changes in building legislation, in particular, Approved Document B [1], Approved Document F [2] and Approved Document J [3]; d) updated appliance design, flue material and practical experience in the disposal of products of combustion by means of flues; e) updated flueing and ventilation installation practices to reduce occurrences of CO related incidents attributable to flueing and ventilation for gas appliances; and f) incorporated, where necessary, additional requirements and guidance previously covered within Technical Bulletins. This publication can be withdrawn, revised, partially superseded or superseded. Information regarding the status of this publication can be found in the Standards Catalogue on the BSI website at bsigroup.com/standards, or by contacting the Customer Services team. Where websites and webpages have been cited, they are provided for ease of reference and are correct at the time of publication. The location of a webpage or website, or its contents, cannot be guaranteed. IV © THE BRITISH STANDARDS INSTITUTION 2023 – ALL RIGHTS RESERVED

Use of this document: It has been assumed in the preparation of this part of BS 5440 that the execution of its provisions will be entrusted to appropriately qualified and experienced people, for whose use it has been produced.

Presentational conventions: The provisions of this document are presented in roman (i.e. upright) type. Its requirements are expressed in sentences in which the principal auxiliary verb is “shall”. Commentary, explanation and general informative material is presented in smaller italic type, and does not constitute a normative element. Requirements in this document are drafted in accordance with the Rules for the structure and drafting of UK standards:2022, subclause G.1.1, which states, “Requirements should be expressed using wording such as: ‘When tested as described in Annex A, the product shall ...’”. This means that only those products that are capable of passing the specified test will be deemed to conform to this document. Where words have alternative spellings, the preferred spelling of the Shorter Oxford English Dictionary is used (e.g. “organization” rather than “organisation”).

Scope: This part of BS 5440 specifies requirements for the installation of gas appliances to chimneys, chimney installation work likely to be undertaken by gas engineers and operatives working under UK gas industry conditions, and requirements for the maintenance of chimneys. It is applicable to open-flued chimneys for Type B gas appliances and room-sealed chimney configurations for Type C gas appliances, each of rated input not exceeding 70 kW net (see Note 2 and Note 3), burning 1st, 2nd or 3rd family gases. It applies to chimneys of the natural draught or fanned draught type and is applicable to room-sealed chimneys and open-flued chimneys supplied with the appliance as well as to those supplied separately. NOTE 1 Type B and Type C appliances are explained in Annex A, Table A.1. This part of BS 5440 complements the requirements for the design, installation and commissioning of chimneys as required in BS EN 15287‑1 and BS EN 15287‑2, and provides extra requirements that are specific to the UK gas industry. This part of BS 5440 specifies the following: a) requirements for the selection of the correct chimney configuration option for gas appliances in the UK; b) requirements for the installation of gas appliances to new chimneys, or chimney configurations; c) requirements for the installation of gas appliances to existing chimneys or chimney configurations; d) requirements for the installation of appliances which carry a CE, UKCA or UKNI mark and for which the manufacturer’s instructions are available to the installer; and e) requirements for the installation of appliances which do not carry a CE, UKCA or UKNI mark and used/second-hand appliances for which the manufacturer’s instructions are available to the installer. This part of BS 5440 is applicable to: 1) complete chimneys and all chimney components from the appliance connection to the discharge point into outside air; 2) the installation of gas appliances to existing chimneys that were intended originally for applian

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
BS 5440-1-2023 PDF

BS 5440-1-2023 PDF

$220.98 $441.96