Code of practice for the operation of fire protection measures-Fire detection and fire alarm systems. Interface with ancillary systems and equipment
Publishing information: This part of BS 7273 is published by BSI Standards Limited, under licence from The British Standards Institution, and came into effect on 31 August 2019. It was prepared by Subcommittee FSH/12/4, Automatic operation of fire protection, under the authority of Technical Committee FSH/12, Fire detection and alarm systems. A list of organizations represented on these committee can be obtained on request to their secretary. Relationship with other publications Part 1: Electrical actuation of gaseous total flooding extinguishing systems; Part 2: Mechanical actuation of gaseous total flooding and local application extinguishing systems; Part 3: Electrical actuation of pre-action watermist and sprinkler systems; Part 4: Actuation of release mechanisms for doors; Part 5: Electrical actuation of watermist systems (except pre-action systems); Part 6: Fire detection and fire alarm systems – Interface with ancillary systems and equipment.
Information about this document: This is a new part of the BS 7273 series. This publication can be withdrawn, revised, partially superseded or superseded. Information regarding the status of this publication can be found in the Standards Catalogue on the BSI website at bsigroup.com/standards, or by contacting the Customer Services team. Where websites and webpages have been cited, they are provided for ease of reference and are correct at the time of publication. The location of a webpage or website, or its contents, cannot be guaranteed.
Use of this document: As a code of practice, this part of BS 7273 takes the form of guidance and recommendations. It should not be quoted as if it were a specification and particular care should be taken to ensure that claims of compliance are not misleading. Any user claiming compliance with this part of BS 7273 is expected to be able to justify any course of action that deviates from its recommendations. It has been assumed in the preparation of this part of BS 7273 that the execution of its provisions will be entrusted to appropriately qualified and experienced people, for whose use it has been produced. Competence of organizations involved in the design and installation of ancillary systems and equipment can be assured by the use of organizations that are third-party certificated, by a UKAS‑accredited certification body, to carry out such activities.
Presentational conventions: The provisions of this standard are presented in roman (i.e. upright) type. Its recommendations are expressed in sentences in which the principal auxiliary verb is “should”. Commentary, explanation and general informative material is presented in smaller italic type, and does not constitute a normative element. ii © THE BRITISH STANDARDS INSTITUTION 2019 – ALL RIGHTS RESERVED Where words have alternative spellings, the preferred spelling of the Shorter Oxford English Dictionary is used (e.g. “organization” rather than “organisation”).
Scope: This part of BS 7273 gives recommendations for the design, installation, commissioning and maintenance of interface arrangements between fire detection and fire alarm systems conforming to BS 5839‑1:2017 and various ancillary systems and equipment (ASE), where this interface is required by the fire strategy for a building, excluding the interface with those systems covered in other parts of the BS 7273 series. Arrangements covered by this part of BS 7273 include the interface between fire detection and fire alarm systems and: smoke control systems; lifts and other lifting appliances; gas valves; fire-resisting shutters and active fire curtain barrier assemblies; electricity supplies; ventilation systems; lighting, intelligent signage and wayfinding; and paging systems. This part of BS 7273 does not apply to the interface between ASE contained solely within a private dwelling and the fire detection and fire alarm system within that dwelling. It applies to systems installed in the common parts of blocks of flats (e.g. activation of the smoke control system), and where the actuation of the detection within a dwelling is intended to interact with a system within common parts (such as in sheltered housing). The scope of this part of BS 7273 is shown diagrammatically in Figure 1. BRITISH STANDARD