BS 7288-2016+A1-2022 PDF

BS 7288-2016+A1-2022 PDF

Specification for residual current devices with or without overcurrent protection for socket-outlets for household and similar uses

$220.98 $441.96 -50%
Publisher
isbn 9780539197099
Product Code: BS 7288
Stock In Stock
Published: 05/18/2022
Number of Pages: 122
File Size: 1 file, 1.9 MB

Available Options

Product Description

Specification for residual current devices with or without overcurrent protection for socket-outlets for household and similar uses

Publishing information: This British Standard is published by BSI Standards Limited, under licence from The British Standards Institution, and came into effect on 30 November 2016. It was prepared by Subcommittee PEL/23/1, Circuit breakers and similar equipment for household use, under the authority of Technical Committee PEL/23, Electrical accessories. A list of organizations represented on these committees can be obtained on request to their secretary. Supersession BS 7288:2016+A1:2022 supersedes BS 7288:2016, which is withdrawn. Relationship with other publications This revision implements IEC 62640 with the common modification applied by HD 62640 and its Amendment No.12:2021.

Information about this document: Text introduced or altered by Amendment(s) No. 1 is indicated in the text by tags . Minor editorial changes are not tagged. This standard reproduces the text of IEC 62640 with the common modifications set out in HD 62640 applied (this is why parts are labelled “void”) and certain necessary requirements retained from BS 7288:1990. The key differences between this edition of BS 7288 and IEC 62640 (with the common modifications) are set out in Annex F. Where IEC 62640 text has been deleted as part of this revision, the words “Text deleted” have been inserted to indicate this. This standard specifies requirements for socket‑outlets incorporating residual current devices (SRCDs). This edition covers the use of the following types of SRCDs: a) single pole with switched neutral; b) double pole; c) single pole with solid neutral. This publication can be withdrawn, revised, partially suspended or suspended. Information regarding the status of this publication can be found in the Standards Catalogue on the BSI website at bsigroup. com/standards, or by contacting the Customer Services team. Where websites and webpages have been cited, they are provided for ease of reference and are correct at the time of publication. The location of a webpage or website, or its contents, cannot be guaranteed.

Use of this document: It has been assumed in the preparation of this British Standard that the execution of its provisions will be entrusted to appropriately qualified and experienced people, for whose use it has been produced. BRITISH STANDARD

Presentational conventions: The provisions of this standard are presented in roman (i.e. upright) type. Its requirements are expressed in sentences in which the principal auxiliary verb is “shall”. Commentary, explanation and general informative material is presented in smaller italic type, and does not constitute a normative element. Where words have alternative spellings, the preferred spelling of the Shorter Oxford English Dictionary is used (e.g. “organization” rather than “organisation”).

Scope: This British Standard applies to residual current‑operated devices (RCD) incorporated in, or specifically intended for use with, single pole and neutral and single pole and switched neutral and double pole socket‑outlets, with provision of earthing of the socket‑outlet for household and similar uses (SRCD: socket‑outlet residual current devices). SRCDs, according to this standard, are intended to be used in single phase systems such as phase to neutral. SRCDs are only intended to provide supplementary protection downstream of the SRCD. SRCDs are intended for use in circuits where the fault protection and additional protection are already assured upstream of the SRCD. NOTE 1 Void. NOTE 2 Void. NOTE 3 Void. SRCDs are only intended to provide additional protection downstream of the SRCD. SRCDs are intended for use in circuits where the fault protection (indirect contact protection) is already assured upstream of the SRCD. NOTE 4 For SRCDs intended to provide isolation or fault protection, or to be used in IT systems, BS EN 61008‑1 or BS EN 61009‑1 should be used, as applicable, in conjunction with the requirements of BS 1363‑2 for socket‑outlets. NOTE 5 Requirements and testing for SRCDs intended to be used in IT systems are under consideration. BRITISH STANDARD

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
BS 7288-2016+A1-2022 PDF

BS 7288-2016+A1-2022 PDF

$220.98 $441.96