BS 7827-2019 PDF

BS 7827-2019 PDF

Designing, specifying, maintaining and operating emergency sound systems for sports grounds, large public buildings, and venues. Code of Practice

$220.98 $441.96 -50%
Publisher
isbn 9780539006377
Product Code: BS 7827
Stock In Stock
Published: 10/24/2019
Number of Pages: 74
File Size: 1 file, 2 MB

Available Options

Product Description

Designing, specifying, maintaining and operating emergency sound systems for sports grounds, large public buildings, and venues. Code of Practice

Publishing information: This British Standard published by BSI Standards Limited, under licence from The British Standards Institution, and came into effect on 31 October 2019. It was prepared by Technical Committee EPL/100, Audio, video and multimedia systems and equipment. A list of organizations represented on this committee can be obtained on request to its secretary. Supersession This British Standard supersedes BS 7827:2011, which is withdrawn. Relationship with other publications This British Standard has been drafted to complement and avoid conflict with other standards with similar scopes, but which are of a more generic nature, i.e. not specifically giving recommendations for large public buildings, venues and sports grounds, notably BS 5839‑8, BS 5839‑9, BS EN 50849 and PD CEN/TS 54‑32. These standards allow for variations from their normal provisions. BS 7827 provides guidance when some of those variations are necessary. BS 7827 indicates where its recommendations can be followed in combination with the provisions of the other standards. This code of practice is applicable to a wide range of buildings including airports, rail and metro/underground stations and transportation terminae which may have their own specific standards and guidance. Whilst the standards listed above take precedence, this code of practice provides additional information where no specific standard or codes of practice exists. See the introduction and Clause 4 where references to related standards are addressed in more detail.

Information about this document: This is a full revision of the standard, and introduces the following principal changes: references to speech intelligibility have been updated to reflect advances in technology and practical experience; information has been provided to help the purchaser understand the need to allow sufficient funding to enable a properly functioning system to be engineered; and cross references to other standards have been updated. This publication can be withdrawn, revised, partially superseded or superseded. Information regarding the status of this publication can be found in the Standards Catalogue on the BSI website at bsigroup.com/standards, or by contacting the Customer Services team. Where websites and webpages have been cited, they are provided for ease of reference and are correct at the time of publication. The location of a webpage or website, or its contents, cannot be guaranteed.

Use of this document: As a code of practice, this British Standard takes the form of guidance and recommendations. It should not be quoted as if it were a specification and particular care should be taken to ensure that claims of compliance are not misleading. Any user claiming compliance with this British Standard is expected to be able to justify any course of action that deviates from its recommendations. BRITISH STANDARD

Presentational conventions: The provisions of this standard are presented in roman (i.e. upright) type. Its recommendations are expressed in sentences in which the principal auxiliary verb is “should”. Commentary, explanation and general informative material is presented in smaller italic type, and does not constitute a normative element. The word “should” is used to express recommendations of this standard. The word “may” is used in the text to express permissibility, e.g. as an alternative to the primary recommendation of the clause. The word “can” is used to express possibility, e.g. a consequence of an action or an event. Notes and commentaries are provided throughout the text of this standard. Notes give references and additional information that are important but do not form part of the recommendations. Commentaries give background information.

Scope: This British Standard gives recommendations and guidance for the design, specification, maintenance and operation of permanently installed sound systems used for emergency purposes at sports grounds, venues and other large buildings/sites that have similar electroacoustic systems, occupancy and occupant-generated sound levels, to convey specific instructions to the public to manage their behaviour in a variety of situations. The standard is applicable to emergencies that require full or partial evacuation and those for which there is a need to keep people inside a building, safe from danger outside. Emergency sound systems in large public buildings, venues and sports grounds are covered by this British Standard as a specific case because these form a class of building or complex which has certain parameters which define a particular need in terms of life safety. These include, but are not restricted to: a) one centralized or several focused performance spaces or activity areas; b) “back of house” areas for operational and administrative purposes; c) large areas of internal circulation; d) large external areas of collection and dispersal, e.g. car and coach parks, railway stations; e) occasional high crowd density; or f) a fully engineered V5 system as defined in BS 5839‑8:2013. In addition to the different types of area, a project is likely to fall under the scope of this British Standard when the venue has the following characteristics: 1) has higher sound pressure level (SPL) requirements than a conventional public address or voice alarm system, typically above 90 dB(A); 2) has several distributed equipment rack locations and/or multiple call/paging points; 3) has complex operational requirements, such as the ability to run simultaneous activities; 4) is a sports stadium or arena; 5) is frequented by large members of the public unfamiliar with the building; 6) has varying operational requirements depending on use, typically event and non-event mode or public and n

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
BS 7827-2019 PDF

BS 7827-2019 PDF

$220.98 $441.96