BS 8899-2016 PDF

BS 8899-2016 PDF

Improvement of fire-fighting and evacuation provisions in existing lifts. Code of practice

$172.72 $345.44 -50%
Publisher
isbn 9780580931918
Product Code: BS 8899
Stock In Stock
Published: 10/31/2016
Number of Pages: 42
File Size: 1 file, 1.5 MB

Available Options

Product Description

Improvement of fire-fighting and evacuation provisions in existing lifts. Code of practice

Publishing information: This British Standard is published by BSI Standards Limited, under licence from The British Standards Institution, and came into effect on 31 October 2016. It was prepared by Technical Committee MHE/4, Lifts, hoists and escalators. A list of organizations represented on this committee can be obtained on request to its secretary.

Information about this document: For more than 75 years, lifts have been used by fire and rescue personnel in fighting fires and evacuation of persons from buildings, but each lift product offered different solutions as to their usability for this purpose. As long ago as 1986, BS 5588-5 gave recommendations for the design of fire-fighting lifts and suitable building design requirements. In more recent years, BS EN 81-72 has been developed to give definitive guidance on the design of new lifts for this purpose, with BS 9999 giving recommendations on suitable building design. This has led to the potential obsolescence of lifts designed and installed prior to application of BS 5588-5 or BS EN 81-72, and it can be challenging for fire and rescue services and others to ascertain exactly which provisions are available on any given lift installation and whether the provisions can be used in practice. BS 8899 has been developed to assist in improving fire-fighting and evacuation provision in lifts installed before the publication of BS EN 81-72:2015.

Use of this document: As a code of practice, this British Standard takes the form of guidance and recommendations. It should not be quoted as if it were a specification and particular care should be taken to ensure that claims of compliance are not misleading. Any user claiming compliance with this British Standard is expected to be able to justify any course of action that deviates from its recommendations. BSI permits the reproduction by individual users of BS 8899:2016, Table A.1. This reproduction is only permitted where it is necessary for the user to use the sample certificates given in the figures during each application of the standard.

Presentational conventions: The provisions of this standard are presented in roman (i.e. upright) type. Its recommendations are expressed in sentences in which the principal auxiliary verb is “should”. Commentary, explanation and general informative material is presented in smaller italic type, and does not constitute a normative element. Where words have alternative spellings, the preferred spelling of the Shorter Oxford English Dictionary is used (e.g. “organization” rather than “organisation”).

Scope: This British Standard gives recommendations for the improvement and maintenance of fire-fighting and evacuation provisions in existing lifts. It applies to lifts installed permanently into buildings that are either already designed for fire and rescue service use or as evacuation lifts, or intended to be modified to include such features. This British Standard is not applicable to: new lifts, whether in new buildings or existing buildings, installed after the publication of this standard; lifts where the building regulations or standards for the fire safety of buildings require or recommend a lift to the level of a new fire-fighting lift, e.g. due to extension or change of use of the building; double-deck lifts; dual entry lifts, where the firefighters lift protected lobbies are not located consistently on the same side of the lift car on all floors served by the installation; lifts with partially enclosed wells; special cases such as potentially explosive atmospheres, extreme climate conditions and seismic conditions. This British Standard covers the significant hazards, hazardous situations and events relevant to lifts for fire and rescue service use and evacuation lifts. NOTE 1 BS EN 81-80 contains recommendations for the general improvement in safety of existing lifts relative to the base lift design standard. BS 8899 is intended to have a similar relationship with BS EN 81-72 and the evacuation lift recommendations in BS 9999. This British Standard applies to the lift installation only. It does not give recommendations for the fire-resisting structure of the building or other elements of the building design and management. NOTE 2 BS 9999 and BS 9991 contain recommendations related to additional building fire safety provisions needed to support the use of fire-fighting and evacuation lifts.

Contents:

  • Foreword
  • Introduction
  • Scope
  • Annexes
  • Annex A (normative) Survey of existing firefighters lift features
  • Annex B (informative) Past provisions for lifts with operation in the event of
  • Annex C (informative) Minimum provisions for lifts used in the evacuation of
  • Annex D (informative) Example of an annual firefighters lift operational
  • Bibliography

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
BS 8899-2016 PDF

BS 8899-2016 PDF

$172.72 $345.44