BS 9251-2021 PDF
Fire sprinkler systems for domestic and residential occupancies. Code of practice
- AA-The Aluminum Association
- AAMI-Association for the Advancement of Medical Instrumentation
- AASHTO-American Association of State Highway and Transportation Officials
- AATCC-American Association of Textile Chemists and Colorists
- ACI-American Concrete Institute
- ANSI-American National Standards Institute
- API-American Petroleum Institute
- AS-Standards Australia
- ASABE-American Society of Agricultural and Biological Engineers (Formerly ASAE)
- ASCE-American Society of Civil Engineers
- ASHRAE-American Society of Heating, Refrigerating, and Air Conditioning Engineers
- ASME-ASME International
- ASTM-ASTM International
- AWS-American Welding Society
- AWWA-American Water Works Association
- BS-BSI Group
- ISO-International Organization for Standardization
- IEC-International Electrotechnical Commission
- IEEE-Institute of Electrical and Electronics Engineers
- SAE-SAE International
- UL-Underwriters Laboratories
- UNE-Asociación Española de Normalización
Your shopping cart is empty!
Product Description
Fire sprinkler systems for domestic and residential occupancies. Code of practice
Publishing information: This British Standard is published by BSI Standards Limited, under licence from The British Standards Institution, and came into effect on 30 June 2021. It was prepared by Subcommittee FSH/18/2, Sprinkler systems, under the authority of Technical Committee FSH/18, Fixed fire fighting systems. A list of organizations represented on these committees can be obtained on request to their committee managers. Supersession This British Standard supersedes BS 9251:2014, which is withdrawn. Relationship with other publications Reference is made in the publication to the advice on selection of fire protection systems set out in BS 5306‑0. Attention is also drawn to the requirements of BS EN 806, with particular regard to backflow prevention, to BS EN 805 where appropriate, and to BS 1710 for guidance on identification and marking of pipework. Where pumps are provided, attention is drawn to the electrical supply requirements of BS 7671. Sprinkler protection for industrial premises and commercial buildings other than those listed in this British Standard is specified in BS EN 12845. Where sprinklers are not installed primarily for life protection in domestic and residential occupancies, sprinkler installations conforming to BS EN 12845 might be more appropriate than those conforming to this British Standard. Guidance on the application of sprinkler systems is given in BS 5306‑0, BS 9991, BS 9999, the Building Regulations 2010, Approved Document B for use in England [1], [2], Wales [3], [4] and its equivalents in Scotland [5], [6] and Northern Ireland [7]. BS 9251 covers fire sprinkler systems for residential and domestic premises that are more than four storeys or above 18 m in height; additionally fixed residential fire sprinkler systems in buildings for residential occupancies up to four storeys or 18 m in height, whichever are lower, are covered in BS EN 16925. FSH/18/2 has detailed their concerns about BS EN 16925 in the National Foreword for that publication.
Information about this document: This is a full revision of the standard, and introduces the following principal changes. Introduction of a fourth category of system to cater for taller residential buildings (greater than 18 m) and higher risk scenarios. The building height of over 18 m for a fourth category was chosen for the following reasons: to align with Fire and Rescue Service national operational guidance, which determines capability, e.g. access and response time; for consistency with BS EN 16925; and greater risk profile in higher rise buildings, including the need for improved resilience. Additional recommendations for larger capacity minimum water supplies for taller buildings and higher risk scenarios. Further recommendations for duplicate pumps and other reliability enhancements in certain scenarios. BRITISH STANDARD Further recommendations for non-residential occupancies in protected buildings. Additional measures and information for the fire service to interact with the installation. Clarification of alarm and fault signalling requirements. Clarification of roles and responsibilities. Product certification/inspection/testing. Users of this British Standard are advised to consider the desirability of third-party certification/inspection/testing of product conformity to this British Standard. Appropriate conformity attestation arrangements are described in BS EN ISO 9001. Users seeking assistance in identifying appropriate conformity assessment bodies or schemes may ask BSI to forward their enquiries to the relevant association. Test laboratory accreditation. Users of this British Standard are advised to consider the desirability of selecting test laboratories that are accredited to BS EN ISO/IEC 17025 by a national or international accreditation body. This publication can be withdrawn, revised, partially superseded or superseded. Information regarding the status of this publication can be found in the Standards Catalogue on the BSI website at bsigroup.com/standards, or by contacting the Customer Services team.
Use of this document: As a code of practice, this British Standard takes the form of guidance and recommendations. It should not be quoted as if it were a specification and particular care should be taken to ensure that claims of compliance are not misleading. Any user claiming compliance with this British Standard is expected to be able to justify any course of action that deviates from its recommendations. It has been assumed in the preparation of this British Standard that the execution of its provisions will be entrusted to appropriately qualified and experienced people, for whose use it has been produced. Where websites and webpages have been cited, they are provided for ease of reference and are correct at the time of publication. The location of a webpage or website, or its contents, cannot be guaranteed.
Presentational conventions: The provisions of this standard are presented in roman (i.e. upright) type. Its recommendations are expressed in sentences in which the principal auxiliary verb is “should”. Commentary, explanation and general informative material is presented in smaller italic type, and does not constitute a normative element.
Scope: This British Standard gives recommendations for the design, installation, components, water supplies and backflow protection, commissioning, maintenance and testing of fire sprinkler systems installed for life safety purposes in residential and domestic premises. NOTE 1 Sprinkler systems also provide additional benefits for property protection and prevention of fire spread. This British Standard is applicable for sprinkler protection of domestic and residential premises and contains specific recommendations for sprinkler systems in those premises of more than four storeys or above 18 m in height. NOTE 2 Unless otherwise specified, references to residential sprinkler system in this British Standard include domestic sprinkler systems. BRITISH STANDARD