Stationary source emissions. Mercury monitoring using sorbent traps

$204.47 $408.94 -50%
Publisher
isbn 9780539049428, 9780580522987
Product Code: BS PD CEN/TS 17286
Stock In Stock
Published: 05/13/2019
Number of Pages: 64
File Size: 1 file, 1.8 MB

Available Options

Product Description

Stationary source emissions. Mercury monitoring using sorbent traps

Scope: The purpose of this document is to establish performance benchmarks for, and to evaluate the acceptability of, sorbent trap monitoring systems used to monitor total vapour- phase mercury (Hg) emissions in stationary source flue gas streams. These monitoring systems involve continuous repetitive in-flue sampling using paired sorbent traps with subsequent analysis of the time-integrated samples. This document is suitable for both short-term (periodic) measurements and long-term (continuous) monitoring using sorbent traps. NOTE When this Technical Specification has been validated, the sorbent trap method will be an Alternative Method subject to the restrictions on applicability defined below. Until that time, EN 13211 is the only accepted Reference Method for both short-term (periodic) measurements and for calibrating continuous monitoring systems, including those with long-term sampling systems. EN 13211 is a wet chemistry approach that relies on absorption of mercury into impinger solutions. The substance measured according to this specification is the total vapour phase mercury in the flue gas, which represents the sum of the elemental mercury (Hg0) and gaseous forms of oxidized mercury (Hg2+), such as mercury (II) chloride, in mass concentration units of micrograms (μg) per dry meter cubed (m3). The analytical range is typically 0,1 to greater than 50 µg/m3. The sorbent tube approach is intended for use under relatively low particulate conditions (typically less than 100 mg/m3) when monitoring downstream of all pollution control devices, e.g. at coal fired power plants and cement plants. In this case, the contribution of mercury in the particulate fraction is considered to be negligible (typically less than 5 % of total mercury). However, it shall be noted that the sorbent trap does take account of the finest particle fraction that is sampled with the flue gas, in addition to capturing the vapour phase mercury. This specification also contains routine procedures an

Contents:

  • Scope
  • 6.1.10 Sample analysis equipment
  • 6.1.11 Sorbent trap spiking system
  • 10.2.1 General
  • 10.2.2 Initial calibration
  • 10.2.3 Initial calibration procedures
  • 10.2.4 Initial calibration factor