BS PD ISO/TR 16043-2015 PDF

BS PD ISO/TR 16043-2015 PDF

Iron ores. Determination of chlorine content. X-ray fluorescence spectrometric method

$147.32 $294.64 -50%
Publisher
isbn 9780580867620
Product Code: BS PD ISO/TR 16043
Stock In Stock
Published: 11/30/2015
Number of Pages: 28
File Size: 1 file, 1.2 MB

Available Options

Product Description

Iron ores. Determination of chlorine content. X-ray fluorescence spectrometric method

Scope: This Technical Report sets out a wavelength dispersive X-ray fluorescence procedure for the determination of chlorine in iron ores. The method is applicable to a concentration range of 0,027 % to 1,15 % of chlorine in iron ores regardless of mineralogical type. It is not intended that this method be used for the purpose of trade in iron ores due to the precision of the method. 2 Principle The glass discs for X-ray fluorescence measurement are prepared by incorporating the test portion of the iron ore sample, via fusion, into a borate glass disc using a casting procedure. By using a fused glass disc, particle size effects are eliminated. The method is applicable to data from simultaneous and sequential X-ray fluorescence spectrometers. Calibration is carried out using pure chemicals, with chlorine added as a stock solution of sodium chloride. Because the oxygen of the flux is the dominant element in the glass disc, and because oxygen is a heavy absorber to Cl Kα, matrix effects are small and calibration is based on a linear relationship between concentration and measured fluorescent intensity. Background measurements are made to determine net line intensities. 3 Reagents and materials 3.1 During analysis, use only reagents of recognized high purity. Where reagents have been ignited, they should be covered during cooling in the desiccator and weighed as soon as possible. 3.2 Iron (III) oxide (Fe2O3), nominally 99,999 % Fe2O3. The iron (III) oxide should contain less than 3 µg/g of chlorine. It should initially be heated at 1 000 °C in a platinum crucible for a minimum of 12 h to reduce contaminant concentrations and cooled in a desiccator. Subsequently, if required, it should be re-ignited at 1 000 °C for 1 h and cooled in a desiccator. 3.3 Sodium chloride (NaCl), 13,2 g/l solution. Analytical grade sodium chloride should be dried at 105 °C for 1 h and cooled in a desiccator. Weigh 13,2 g dried sodium chloride into a 1 000 ml one-mark volumetric flask and dilute to vo

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
BS PD ISO/TR 16043-2015 PDF

BS PD ISO/TR 16043-2015 PDF

$147.32 $294.64