BS PD ISO/TR 16840-9-2015 PDF

BS PD ISO/TR 16840-9-2015 PDF

Wheelchair seating-Clinical interface pressure mapping guidelines for seating

$147.32 $294.64 -50%
Publisher
isbn 9780580874062
Product Code: BS PD ISO/TR 16840-9
Stock In Stock
Published: 07/31/2015
Number of Pages: 30
File Size: 1 file, 1.7 MB

Available Options

Product Description

Wheelchair seating-Clinical interface pressure mapping guidelines for seating

Scope: This Technical Report has been produced to guide users in the performance of the tasks that are directly involved in the clinical use of interface pressure mapping (IPM) or are synergistic with its use in a comprehensive wheelchair seating evaluation. This Technical Report does not cover other aspects of the clinical assessment process (e.g. taking a medical history), nor the prescription or treatment process which might arise from an assessment. These guidelines are not meant to be a substitute for clinical reasoning and judgement within the context of a complete assessment. This Technical Report refers to the state of the art of IPM experiences in a seating scenario. Most of the principles covered can be extrapolated to whole body (in bed) or to foot assessments, for example. 2 Definitions and glossary 2.1 Calibration Calibration is a process wherein the sensing mat is subjected to known forces. The sensor responses are monitored and modelled in the software. NOTE A record is kept of the responses (called a calibration file) and whenever the sensors output a similar response, the result is related to the previously known forces. In most cases, this is done by placing the mat in a purpose-built chamber with an air-filled bladder. The bladder is inflated and the pressure in the bladder is measured. It is assumed to be evenly pressurized over the mat. Calibration allows for the software to accommodate changes with time (creep) or pressure (hysteresis) exhibited by the sensors. Recalibrate the mat whenever the readings look unreliable, after excessive use, or at the manufacturer’s recommended interval. Keep track of the uses of the mat and the date of the last calibration. Old calibration files should be retained (old calibration files can be loaded for comparison to determine change over a period). 2.2 Coefficient of Variation (CoV) The CoV is expressed as a percentage: Coefficient of Variation S dard deviation Mean = tan (1) NOTE This is one of the statistical measu

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
BS PD ISO/TR 16840-9-2015 PDF

BS PD ISO/TR 16840-9-2015 PDF

$147.32 $294.64