BS PD ISO/TS 19930-2017 PDF

BS PD ISO/TS 19930-2017 PDF

Guidance on aspects of a risk-based approach to assuring sterility of terminally sterilized, single-use health care product that is unable to withstand processing to achieve maximally a sterility assurance level of 10-6

$147.32 $294.64 -50%
Publisher
isbn 9780580951619
Product Code: BS PD ISO/TS 19930
Stock In Stock
Published: 12/01/2017
Number of Pages: 32
File Size: 1 file, 960 KB

Available Options

Product Description

Guidance on aspects of a risk-based approach to assuring sterility of terminally sterilized, single-use health care product that is unable to withstand processing to achieve maximally a sterility assurance level of 10-6

Scope: This document provides guidance on identifying the aspects to be considered as part of a risk-based approach to selecting a sterility assurance level (SAL) for terminally sterilized, single-use health care product that is unable to withstand processing to achieve maximally a SAL of 10−6. In addition, this document provides a) background information on the assurance of sterility and sterility assurance level, and b) guidance on strategies that can allow the achievement of a maximal SAL of 10−6. This document describes the elements of a quality management system which are applied to enable the appropriate selection of a SAL for terminally sterilized, single-use health care product that is unable to withstand processing to achieve maximally a SAL of 10−6. NOTE It is not a requirement of the International Standards for development, validation and routine control of a sterilization process to have a full quality management system. Attention is drawn to the standard for quality management systems (see ISO 13485) that controls all stages of the lifecycle of health care product. This document is applicable to sterilization processes in which microorganisms are inactivated by physical and/or chemical means. This document does not apply — to selecting a maximal SAL greater than 10−6 for health care product that is able to withstand processing to achieve maximally a SAL of 10−6; — in cases where a maximal SAL of 10−6 is required and an alternative SAL is not allowed; — in cases where a maximal SAL of greater than 10−6 (e.g. 10−3) has been accepted by regulatory authorities within their jurisdiction for health care product for defined use; — to the sterilization of used or reprocessed health care product; — to sterilization of health care product by filtration. This document does not describe detailed procedures for assessing microbial inactivation. This document does not specify requirements for the development, validation and routine control of a process for inactivating the

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
BS PD ISO/TS 19930-2017 PDF

BS PD ISO/TS 19930-2017 PDF

$147.32 $294.64