BS PAS 79-1-2020 PDF
Fire risk assessment-Premises other than housing. Code of practice
- AA-The Aluminum Association
- AAMI-Association for the Advancement of Medical Instrumentation
- AASHTO-American Association of State Highway and Transportation Officials
- AATCC-American Association of Textile Chemists and Colorists
- ACI-American Concrete Institute
- ANSI-American National Standards Institute
- API-American Petroleum Institute
- AS-Standards Australia
- ASABE-American Society of Agricultural and Biological Engineers (Formerly ASAE)
- ASCE-American Society of Civil Engineers
- ASHRAE-American Society of Heating, Refrigerating, and Air Conditioning Engineers
- ASME-ASME International
- ASTM-ASTM International
- AWS-American Welding Society
- AWWA-American Water Works Association
- BS-BSI Group
- ISO-International Organization for Standardization
- IEC-International Electrotechnical Commission
- IEEE-Institute of Electrical and Electronics Engineers
- SAE-SAE International
- UL-Underwriters Laboratories
- UNE-Asociación Española de Normalización
Your shopping cart is empty!
Product Description
Fire risk assessment-Premises other than housing. Code of practice
This is a full revision of the document, and introduces the following principal changes. • PAS 79 has been split into two parts, with PAS 79-1 dealing with non-housing premises and PAS 79-2 dealing with housing premises. • The scope of this new Part 1 of PAS 79 excludes blocks of flats, sheltered housing, extra care housing, supported housing and certain houses in multiple occupation (i.e. those falling within the scope of the relevant fire safety legislation), all of which are addressed in a new Part 2 of PAS 79. • PAS 79-1 is a code of practice, whereas PAS 79:2012 was a guide. PAS 79:2012 was already written in the form of a code of practice, and the change in status is simply to recognize this, noting that guides are not usually of such a nature as to sustain a reliable claim of compliance. • The technical content has been subject to amendment in the light of experience in the use of PAS 79:2012. • There is new guidance on the consideration to be given to external wall construction and cladding, which takes into account knowledge, current at the time of publication, arising from the fire disaster at Grenfell Tower, a high-rise block of flats in London, in 2017. • There is recognition of pre-occupation fire safety assessments, a term now defined in this PAS, and a clarification to avoid confusion between those assessments and the fire risk assessment to which this PAS refers. • There is even greater emphasis on competence of fire risk assessors and reference to future competence standards in consequence of the Hackitt Review of building regulations and fire safety, which was ordered by the Government following the fire at Grenfell Tower. It is also noted in this PAS that fire safety specialists with experience only in the design of new buildings might not possess an appreciation of standards against which older buildings were designed and the possible continued acceptability of such standards. • Changes to, and publication of relevant new, British Standards have been taken into account. This publication can be withdrawn, revised, partially superseded or superseded. Information regarding the status of this publication can be found in the Standards Catalogue on the BSI website at bsigroup.com/ standards, or by contacting the Customer Services team. Where websites and webpages have been cited, they are provided for ease of reference and are correct at the time of publication. The location of a webpage or website, or its contents, cannot be guaranteed.
Use of this document: As a code of practice, this PAS takes the form of guidance and recommendations. It should not be quoted as if it were a specification, and particular care should be taken to ensure that claims of compliance are not misleading. Any user claiming compliance with this PAS is expected to be able to justify any course of action that deviates from its recommendations. It has been assumed in the drafting of this PAS that the execution of its provisions will be entrusted to appropriately qualified and competent people, for whose use it has been produced. The copyright for Annex A, Annex D and Annex E of this PAS, and for the electronic copies of the separately available pro formas (including the modified versions for use in Scotland and Northern Ireland), is owned by C.S. Todd & Associates Ltd. Purchasers of this PAS are authorized to use the pro formas contained within Annex A and Annex D, and the separately available electronic copies, and to make an unlimited number of copies for their own use, without infringement of copyright. However, following the recommendations given in this PAS does not necessitate use of these pro formas. This PAS is not intended to constitute a textbook on fire safety, and it is not to be regarded as a substitute for knowledge of fire safety principles and the practical use and application of fire protection measures or an understanding of the premises, their features, usage and occupancy. In carrying out the fire risk assessment, there is likely to be a need for reference to other codes of practice and guidance documents on specific aspects of fire prevention, fire protection and management of fire safety, a number of which are listed in the Bibliography. Moreover, this PAS is not intended to provide guidance on the detailed requirements of the relevant fire safety legislation. Such guidance can be found in the relevant government guidance documents listed in the Bibliography.
Presentational conventions: The provisions of this PAS are presented in roman (i.e. upright) type. Its recommendations are expressed in sentences in which the principal auxiliary verb is “should”. Commentary, explanation and general informative material is presented in smaller italic type, and does not constitute a normative element. Where words have alternative spellings, the preferred spelling of the Shorter Oxford English Dictionary is used (e.g. “organization” rather than “organisation”). The word “should” is used to express recommendations of this PAS. The word “may” is used in the text to express permissibility, e.g. as an alternative to the primary recommendation of the clause. The word “can” is used to express possibility, e.g. a consequence of an action or an event. Notes and commentaries are provided throughout the text of this PAS. Notes give references and additional information that are important but do not form part of the recommendations. Commentaries give background information. It is envisaged that, when a fire risk assessment is audited for compliance with this PAS, the audit will be based on the recommendations only.