Application of fire safety engineering principles to the design of buildings-Human factors: Life safety strategies. Occupant evacuation, behaviour and condition (Sub-system 6)
Publishing information: This Published Document is published by BSI Standards Limited, under licence from The British Standards Institution, and came into effect on 31 March 2019. It was prepared by Technical Committee FSH/24, Fire safety engineering. A list of organizations represented on this committee can be obtained on request to its secretary. Supersession This Published Document supersedes PD 7974-6:2004, which is withdrawn. Relationship with other publications The parts of PD 7974 are structured as follows: PD 7974-1, Initiation and development of fire within the enclosure of origin; PD 7974-2, Spread of smoke and toxic gases within and beyond the enclosure of origin; PD 7974-3, Structural response and fire spread beyond the enclosure of origin; PD 7974-4, Detection of fire and activation of fire protection systems; PD 7974-5, Fire service intervention; PD 7974-6, Occupant evacuation, behaviour and condition; and PD 7974-7, Probabilistic fire risk assessment. This series of Published Documents are intended to be used in support of BS 7974, but do not represent the only means of satisfying the recommendations of the code of practice.
Information about this document: This Published Document can be used to set specific acceptance criteria and undertake detailed analysis for escape and tenability. It can be used to identify and define one or more fire safety design issues to be addressed using fire safety engineering. This is a full revision of the Published Document, and introduces the following principal changes. The principal guidance and bibliography have been updated in line with recent developments and publications since 2004. The data tables in the annexes have been expanded to include more recently published data and bibliography. A full set of expressions has been provided for fractional effective dose calculations with worked examples to illustrate the calculation methods.
Use of this document: This publication is not to be regarded as a British Standard. As a guide, this Published Document takes the form of guidance and recommendations. It should not be quoted as if it were a specification or a code of practice and claims of compliance cannot be made to it. It has been assumed in the preparation of this Published Document that the execution of its provisions will be entrusted to appropriately qualified and experienced people, for whose use it has been produced. PUBLISHED DOCUMENT PD 7974‑6:2019
Presentational conventions: The guidance in this Published Document is presented in roman (i.e. upright) type. Any recommendations are expressed in sentences in which the principal auxiliary verb is “should”. Commentary, explanation and general informative material is presented in smaller italic type, and does not constitute a normative element. Where words have alternative spellings, the preferred spelling of The Shorter Oxford English Dictionary is used (e.g. “organization” rather than “organisation”).
Scope: This Published Document is intended to provide guidance to designers, regulators and fire safety professionals on the engineering methods available for the evaluation of life safety aspects of a fire safety engineering design in relation to escape and tenability strategies. The objective of the fire safety engineering strategy is to ensure exposure to the effects of fire does not impede the safe escape of occupants or cause exposure to conditions leading to adverse health effects. Guidance is presented regarding the evaluation and management of occupant behaviour during a fire emergency and for the evaluation of occupant condition related to exposure to fire effluent and heat. This Published Document addresses the parameters that underlie the basic principles of designing for life safety and provides guidance on the processes, assessments and calculations necessary to determine the location and condition of the occupants of the building, with respect to time. This is achieved using the information presented on the evaluation, quantification and management of occupant behaviour, particularly escape behaviour, during a fire emergency. This Published Document also provides a framework for reviewing the suitability of an engineering method for assessing the life safety potential of a building for its occupants. PUBLISHED DOCUMENT PD 7974‑6:2019