BS PD CEN/TR 10350-2013 PDF

BS PD CEN/TR 10350-2013 PDF

Analysis of steels and irons. Internal laboratory procedure for checking the accuracy of an analytical method by using Certified Reference Materials

$147.32 $294.64 -50%
Publisher
isbn 9780580777103
Product Code: BS PD CEN/TR 10350
Stock In Stock
Published: 03/31/2013
Number of Pages: 28
File Size: 1 file, 1.1 MB

Available Options

Product Description

Analysis of steels and irons. Internal laboratory procedure for checking the accuracy of an analytical method by using Certified Reference Materials

Scope: The present statistical procedure describes how to check results for absence of bias by comparison of these analytical results with those obtained during the certification of CRMs. If the resulting data confirm the absence of bias, the method may be considered accurate when applied to all steels and irons whose composition ranges are adequately covered or bounded by the CRMs used. The resulting data give also an estimate of the repeatability and/or the intermediate precision ("intralaboratory reproducibility") for the CRMs used. The comparison of these analytical data with the repeatability data obtained during the certification may also be performed depending on the strict purpose of the method under consideration. For the purpose of this Technical Report, the use of existing CRMs is essential for the assessment of the trueness, but it may be only indicative for the other statistical data. NOTE This Technical Report does not describe the use of CRMs as calibrants, this subject being treated in ISO Guide 32. Principle This Technical Report describes a procedure for checking an analytical method used in a specific laboratory by using data obtained from the analysis of CRMs. The absence of bias ascertained with CRMs can be extended to the trueness of further analytical samples adequately covered or bounded by the selected CRMs. Nevertheless it should be underlined that this Technical Report is not appropriate for the assessment of the repeatability and/or the intermediate precision data of the further analytical samples to be tested by the analytical method under consideration. Checking the trueness of an analytical method as applied by a specific laboratory involves the comparison of the mean value of the analytical results obtained by using CRMs with the certified value of each CRM selected. The standard deviation of the intralaboratory means of the selected CRMs is taken into account when making this comparison. Moreover, adjustment values chosen in advance by the

Contents:

  • Foreword
  • Introduction
  • Scope
  • Annex A (informative) Symbols used
  • Annex B (informative) Table of the χ2 distribution
  • Annex C (informative) Examples
  • Bibliography

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
BS PD CEN/TR 10350-2013 PDF

BS PD CEN/TR 10350-2013 PDF

$147.32 $294.64