BS PD CEN/TS 14416-2014 PDF

BS PD CEN/TS 14416-2014 PDF

Geosynthetic barriers. Test method for determining the resistance to roots

$90.17 $180.34 -50%
Publisher
isbn 9780580833151
Product Code: BS PD CEN/TS 14416
Stock In Stock
Published: 03/31/2014
Number of Pages: 12
File Size: 1 file, 890 KB

Available Options

Product Description

Geosynthetic barriers. Test method for determining the resistance to roots

Scope: This Technical Specification describes a laboratory procedure for the rapid testing of the resistance of polymeric, bituminous or clay geosynthetic barriers to root penetration. It is suitable for testing of welded seams or other areas of potential weakness. A longer test that may be more suitable for testing the long-term resistance of geosynthetic barriers is described in EN 13948. Principle A section of geosynthetic barrier is placed in soil into which seeds are sown. Six to eight weeks later the geosynthetic barrier is examined to see whether it has been penetrated by the roots of the young plants. Apparatus The following equipment shall be used: — four dry unglazed clay flower pots approximately 220 mm high. The diameter at the base of the pot shall be approximately 140 mm, the diameter at the top 250 mm, and the angle between side and central axis approximately 13°. A 40 mm wide band shall be painted on the inside of the pot, about 100 mm above the base, and allowed to dry; — lime-free soil (pH 5 to 6), mixed with a little loam or high quality potting soil; Compost should not be used. — lupin seeds (lupinus alba); — silicone mastic sealant or mortar-sand mixture; — bitumen 85/40; — glass tubes; — anti-mould agent. Procedure — Fill the pots with the soil as far as the lower edge of the painted band, then seal and humidify. — Cut three discs of geosynthetic barrier to cover the soil exactly. — Place the geosynthetic barrier on the soil of three of the pots with the upper side uppermost. — Carefully seal the gap between geosynthetic barrier and pot with the sealant or mortar-sand mixture. — Prepare the fourth pot in which the geosynthetic barrier is replaced by a 20 mm thick layer of bitumen 85/40 (oxidized grade bitumen with a softening point of (85 ± 5) °C and a penetration temperature of (40 ± 5) °C). — Cover the geosynthetic barrier or the bitumen with 90 mm of soil, then seal and humidify.

Contents:

  • Foreword
  • Introduction
  • Scope
  • Bibliography

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
BS PD CEN/TS 14416-2014 PDF

BS PD CEN/TS 14416-2014 PDF

$90.17 $180.34