BS PD CLC/TR 50422-2013 PDF

BS PD CLC/TR 50422-2013 PDF

Guide for the application of the European Standard EN 50160

$194.31 $388.62 -50%
Publisher
isbn 9780580784538
Product Code: BS PD CLC/TR 50422
Stock In Stock
Published: 09/30/2013
Number of Pages: 48
File Size: 1 file, 1.3 MB

Available Options

Product Description

Guide for the application of the European Standard EN 50160

Scope: The aim of this Technical Report is to provide background information and explanations on EN 50160 with regard to the history of its development as well as to its correct application. Historical overview of the Standard and its development 2.1 Historical development The very first document dealing with some set of PQ characteristics – and therefore the origin of a related European Standard some 13 years later – was an article published by the International Union of Producers and Distributors of Electric Energy (UNIPEDE) in their magazine “Electricity Supply”, in May 1981 [32]. Experts of UNIPEDE WG “DISPERT” were commissioned “to define the different kinds of disturbances, which can affect LV distribution voltage, caused by periodical or transient phenomena, resulting in overvoltages, voltage dips, or other kinds of irregularities in the voltage wave”. This document was prepared on the basis of information collected by European distributors, for the purpose of providing information to network users fed from LV systems and to appliance designers on the actual characteristics of the voltage distributed. It provided information about a set of characteristics:  being recognised as representing the main irregularities in the LV supply voltage;  being assumed as covering about 95 % of the cases;  representing real supply voltage characteristics, to be taken into account at designing electrical and electronic equipment with respect to their undegraded operation on mains supply;  not intended to represent limit values, but with a view to acceptable values, distinguished in four groups: a) (quasi)stationary phenomena, mostly with close relation to 50 Hz:  slow voltage variations;  frequency variation;  unbalance of three-phase voltages;  harmonic voltage distortion;  sudden voltage changes;  DC component; b) caused by occasional transient phenomena:  voltage dips;  transient voltage depressions;  spikes originating in the operation of electrical equipment;  sur

Contents:

  • Foreword
  • Introduction
  • Scope
  • Annex A (informative) Distributed generation and its impact on the supply voltage
  • Annex B (informative) Voltage / current components in the frequency range 2 kHz – 150 kHz and
  • Annex C (informative) Overvoltages

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
BS PD CLC/TR 50422-2013 PDF

BS PD CLC/TR 50422-2013 PDF

$194.31 $388.62