BS PD ISO/TR 16386-2014 PDF

BS PD ISO/TR 16386-2014 PDF

Impact of changes in ISO fluid power particle counting. Contamination control and filter test standards

$105.41 $210.82 -50%
Publisher
isbn 9780580785443
Product Code: BS PD ISO/TR 16386
Stock In Stock
Published: 11/30/2014
Number of Pages: 22
File Size: 1 file, 1.2 MB

Available Options

Product Description

Impact of changes in ISO fluid power particle counting. Contamination control and filter test standards

Scope: This Technical Report discusses the impact of changes in International Standards for particle counting, contamination control, and filter testing. Liquid automatic particle counters (APCs) are used in monitoring contamination levels in hydraulic fluids, to establish component and assembly cleanliness level specifications, and in determining filter efficiencies and particle size ratings. As a result of the replacement of ISO 4402 with ISO 11171 (APC calibration), the replacement of ISO 4572 with ISO 16889 (multi-pass filter test), and the publication of ISO 11943 (online particle counter calibration), the quality and reliability of particle count and filter test data have improved, increasing their usefulness to industry. However, the resultant redefinition of particle sizes and the use of a new test dust affect how contamination levels and filter performance are reported and interpreted. NOTE The first editions of ISO 11171, ISO 16889 and ISO 11943 were published in 1999; all three of these International Standards either have been, or are in the process of being, revised. 2 Historical background 2.1 What is ACFTD? ACFTD was a test dust that was originally produced in batches by the AC Spark Plug Division of General Motors Corporation. ACFTD was manufactured by collecting dust from a certain location in Arizona (USA), then ball milling and classifying it into a consistent particle size distribution, including particle sizes from roughly 0 μm to 100 μm. The manufacturer supplied the average volumetric particle size distribution of each batch of ACFTD, as determined by either the roller analyser of laser diffraction technique. In 1992, the production of ACFTD ceased. Because of its relatively consistent particle size distribution, ACFTD had been used to calibrate APCs in ISO 4402 and to evaluate filter performance in ISO 4572 for hydraulic and other applications. With its irregular shape and siliceous nature, ACFTD was believed to be representative of contaminants foun

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
BS PD ISO/TR 16386-2014 PDF

BS PD ISO/TR 16386-2014 PDF

$105.41 $210.82