ISO TR 6307-2023 PDF

ISO TR 6307-2023 PDF

Effect of conductivity on multipass testing as per ISO 4548-12:2017

$48.00 $96.00 -50%
Product Code: ISO TR 6307
Stock In Stock
Edition: 1.
Published: 09/2023
Number of Pages: 18
File Size: 1 file, 1 Byte

Available Options

Product Description

Effect of conductivity on multipass testing as per ISO 4548-12:2017

Introduction: ISO 4548-12:2000 and ISO 4548-12:2017 state that oil (MIL-PRF-5606, AIR 3520 and other suitable fluids) conductivity is to be set to “at least 1 000 pS/m” prior to conducting a lubricating oil filter, with a recommended level of “1 500 pS/m +/- 500 pS/m.” Prior to the revision of ISO 4548-12:2000 (started in 2016), fluid conductivity had received increasing attention. Some labs reported issues with maintaining fluid conductivity during these tests and discussed the effects conductivity can have on filter capacity results. Testing showed the fluid conductivity can decrease during a test, which corresponded to an increase in filter capacity. A task force was established within ISO/TC70/SC7/WG2 to investigate this issue. Findings from this work are summarized in this document. The root cause of the fluid conductivity problem was not discovered and most labs did not report any issues with maintaining conductivity during ISO 4548-12 testing. Experiments were conducted by one laboratory, oil was examined by two laboratories, and survey results were sent from nine laboratories. Three sets of experiments were conducted including testing with flat sheet samples and commercially available filters to examine the effect of fluid conductivity change. Fresh and aged oil were examined to see if any components of the fluid were depleted during normal use. © ISO 2023 – All rights reserved

Scope: This document outlines the importance of conductivity in multi-pass filter testing per ISO 4548-12. This information also applies to filters tested per other multi-pass filter test standards, such as ISO 16889 and ISO 19438. Filters tested according to each method can experience similar changes in performance during the fluid conductivity changes outlined within this document. The objectives of this document are to clarify the following issues: — Examine how conductivity affects filter capacity test results when filters are tested per ISO 4548-12:2017. — Compare findings to ISO 4548-12:2017 operating parameters.

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
ISO TR 6307-2023 PDF

ISO TR 6307-2023 PDF

$48.00 $96.00