UL 1655-2024 PDF
UL Standard for Safety Community-Antenna Television Cables
- 3A-3-A Sanitary Standards
- 9000-9000 Store
- A3-Association for Advancing Automation
- A4A-Airlines for America
- AA-The Aluminum Association
- AAMI-Association for the Advancement of Medical Instrumentation
- AASHTO-American Association of State Highway and Transportation Officials
- AATCC-American Association of Textile Chemists and Colorists
- ABCB-Australian Building Codes Board
- ABMA-American Bearing Manufacturers Association
- ABMA-BOILER-American Boiler Manufacturers Association
- ACC-American Chemistry Council
- ACGIH-American Conference of Governmental Industrial Hygienists
- ACI-American Concrete Institute
- AEIC-Association of Edison Illuminating Companies
- AES-Audio Engineering Society
- AFCEN-French Association
- AGA-American Gas Association
- AGMA-American Gear Manufacturers Association
- AHAM-Association of Home Appliance Manufacturers
- AHP-American Herbal Pharmacopoeia
- AHRI-Air-Conditioning, Heating, and Refrigeration Institute (formerly ARI)
- AIA-Aerospace Industries Association
- AIAA-American Institute of Aeronautics and Astronautics
- AICHE-American Institute of Chemical Engineers
- AIHA-American Industrial Hygiene Association
- AISC-American Institute of Steel Construction
- ALI-American Ladder Institute
- ALPEMA-Aluminium Plate-Fin Heat Exchanger Manufacturers' Association
- AMCA-Air Movement and Control Association
- ANS-American Nuclear Society
- ANSI-American National Standards Institute
- ANSI/ANSLG-American National Standards Institute / American National Standard Lighting Group
- ANSI/NEMA-American National Standards Institute / National Electrical Manufacturers Association
- ANSI/TCNA-Tile Council of North America, Inc.
- ANSI/UAMA-Unified Abrasives Manufacturers' Association
- API-American Petroleum Institute
- APWA-American Public Works Association
- AREMA-American Railway Engineering and Maintenance-of-Way Association
- ARINC-ARINC Industry Activities
- ARMY-United States Army Publication
- AS-Standards Australia
- ASA-Acoustical Society of America Standards
- ASABE-American Society of Agricultural and Biological Engineers (Formerly ASAE)
- ASCE-American Society of Civil Engineers
- ASD-STAN prEN-ASD-STAN Standardization
- ASHE-American Society for Healthcare Engineering
- ASHRAE-American Society of Heating, Refrigerating, and Air Conditioning Engineers
- ASIS-ASIS International
- ASM-ASM International
- ASME-ASME International
- ASNT-The American Society for Nondestructive Testing
- ASQ-American Society for Quality
- ASSE (Plumbing)-American Society of Sanitary Engineering
- ATIS-The Alliance for Telecommunications Industry Solutions
- ASTM-ASTM International
- AVIXA-Audiovisual and Integrated Experience Association
- AWC-American Wood Council
- AWI-Architectural Woodwork Institute
- AWS-American Welding Society
- AWWA-American Water Works Association
- AWPA-American Wood Protection Association
- B11-B11 Standards, Inc.
- BHMA-Builders Hardware Manufacturers Association
- BICSI-BICSI, A Telecommunications Association
- BioWorld-Thomson Reuters BioWorld
- BMI-Battelle - Metallic Materials Properties Development and Standardization (MMPDS)
- BS-BSI Group
- CAN/CGSB-Canadian General Standards Board
- CAN/ULC-Underwriters Laboratories of Canada
- CEI-Comitato Elettrotecnico Italiano
- CFR-Code of Federal Regulations
- CGA-Compressed Gas Association
- CIE-Commission Internationale de L'Eclairage
- CII-Construction Industry Institute
- CISPR-International Special Committee on Radio Interference
- CLSI-Clinical and Laboratory Standards Institute
- CMAA-Crane Manufacturers Association of America, Inc.
- CRANE-Crane Co.
- CRSI-Concrete Reinforcing Steel Institute
- CSA-Canadian Standards Association
- CTA-Consumer Technology Association (Formerly CEA)
- CTI-Cooling Technology Institute
- DANSK-Dansk Standard
- DID-Data Item Description
- DIN-Deutsches Institut Fur Normung E.V. (German National Standard)
- DNV-DNV
- DOD-Department of Defense
- DOXPUB-Doxpub, Inc.
- DVS-DEUTSCHER VERBAND FÜR SCHWEISSEN UND VERWANDTE VERFAHREN E.V.
- ECIA-Electronic Components Industry Association
- EEC-European Union Directives
- EEMUA-Engineering Equipment and Materials Users Association
- ESD-EOS/ESD Association, Inc.
- ETSI-European Telecommunications Standards Institute
- FCI-Fluid Controls Institute
- ISO-International Organization for Standardization
- ISO/IEC/IEEE-International Organization for Standardization / International Electrotechnical Commission / Institute of Electrical and Electronics Engineers
- ISPE-International Society for Pharmaceutical Engineering
- FED-Federal Specifications and Standards
- ISTA-International Safe Transit Association
- ISUZU-Isuzu Motors Ltd.
- FM Approvals-FM Approvals
- JEDEC-JEDEC Solid State Technology Association
- JSA-Japanese Standards Association (JIS Standards)
- LIA-Laser Institute of America
- FORD-Ford Motor Company
- MBMA-Metal Building Manufacturers Association
- MCGRAW-HILL-McGraw-Hill Publishing Company
- FRPI-Fiberglass Reinforced Plastics Institute, Inc.
- MIL-Military Specifications and Standards
- MPIF-Metal Powder Industries Federation
- MPMA-Motion + Power Manufacturers Alliance (MPMA) (Formerly AGMA & ABMA)
- GMW-General Motors Worldwide
- MSS-Manufacturers Standardization Society of the Valve and Fittings Industry
- NAAMM-National Association of Architectural Metal Manufacturers
- GPA-GPA Midstream Association
- NACE-National Association of Corrosion Engineers
- NADCA-National Air Duct Cleaners Association
- NAS-Aerospace Industries Association - National Aerospace Standard
- HEI-Heat Exchange Institute
- NASA-National Aeronautics and Space Administration
- NBBI-The National Board of Boiler and Pressure Vessel Inspectors
- NCSL-National Conference of Standards Laboratories International
- HFES-Human Factors and Ergonomics Society
- NECA-National Electrical Contractors Association
- RTCA-RTCA, Inc.
- HI-Hydraulic Institute
- NEMA-National Electrical Manufacturers Association
- NETA-InterNational Electrical Testing Association
- NFPA (Fire)-National Fire Protection Association
- HIR-H.I.R. Technical Services
- NFPA (Fluid)-National Fluid Power Association
- NFSI-National Floor Safety Institute
- HPS-Health Physics Society
- NGA-National Glass Association
- NISO-National Information Standards Organization
- NORSOK-NORSOK
- I3A-International Imaging Industry Association
- NRC-National Research Council Canada
- NSC-Natural Stone Council
- IADC-International Association of Drilling Contractors
- NSF-NSF International
- NZS-Standards New Zealand
- OPEI-Outdoor Power Equipment Institute
- IAPMO-International Association of Plumbing and Mechanical Officials
- PCI-Precast/Prestressed Concrete Institute
- PDA-Parenteral Drug Association
- IATA-International Air Transport Association
- PEI-Petroleum Equipment Institute
- PFI-Pipe Fabrication Institute
- PIA-Parachute Industry Association
- ICAO-International Civil Aviation Organization
- PIP-Process Industry Practices
- PPI-Plastics Pipe Institute
- ICC-International Code Council
- PTI-Post-Tensioning Institute
- ICEA-Insulated Cable Engineers Association
- ICML-International Council for Machinery Lubrication
- IEC-International Electrotechnical Commission
- IEEE-Institute of Electrical and Electronics Engineers
- IES-Illuminating Engineering Society
- IEST-Institute of Environmental Sciences and Technology
- IFI-Industrial Fasteners Institute
- IICRC-Institute of Inspection, Cleaning and Restoration Certification
- INCITS-InterNational Committee for Information Technology Standards (formerly NCITS)
- INTERN-International Motors, LLC (Formerly NAVISTAR)
- IPC-IPC by Global Electronics Association
- ISA-International Society of Automation
- ISEA-International Safety Equipment Association
- SAE-SAE International
- SAIA-Scaffold & Access Industry Association
- SCTE-Society of Cable Telecommunication Engineers
- SDI-Steel Door Institute
- SES-The Society for Standards Professionals
- SIA-Security Industry Association
- SJI-Steel Joist Institute
- SMACNA-Sheet Metal and Air Conditioning Contractors' National Association
- SME-Society of Manufacturing Engineers
- SMPTE-Society of Motion Picture and Television Engineers
- SN EN-Standards Norway EN
- SPC-Standards Press of China
- SPI-Society of the Plastics Industry
- SSPC-Society for Protective Coatings
- STI/SPFA-Steel Tank Institute/Steel Plate Fabricators Association
- TAPPI-Technical Association of the Pulp and Paper Industry
- TCIA-Tree Care Industry Association
- TEMA-Tubular Exchanger Manufacturers Association
- THHILL-TH Hill Associates, Inc.
- TIA-Telecommunications Industry Association
- TMS-The Masonry Society
- UL-Underwriters Laboratories
- ULC-Underwriters Laboratories of Canada
- UNE-Asociación Española de Normalización
- WILEY-John Wiley and Sons
- WRC-Welding Research Council, Inc.
- WSPC-World Scientific Publishing Co.
- X9-Accredited Standards Committee X9 Incorporated
Your shopping cart is empty!
Product Description
This Standard states the construction, test, and marking requirements covering the safety of single and multiple coaxial and coaxial/optical-fiber cables for the distribution of radio frequency signals such as employed in a community antenna television system, and for supplying low-energy power at a potential not exceeding 60 volts to equipment directly associated with the signal distribution. These are power-limited cables and are of the following types for installation and use as the CATV cables specified in Article 820 and other applicable parts of the National Electrical Code (NEC), NFPA 70. Electrically nonconductive material separates each optical-fiber member from the rest of the cable. a) PLENUM CABLES – Type CATVP (coaxial) and Type CATVP-OF (coaxial/optical-fiber). These cables are for installation as specified in Section 800.179(A) of the National Electrical Code, NFPA 70 in a duct, plenum, or other space used to transport environmental air without the cable being enclosed in raceway in that space. b) RISER CABLES – Type CATVR (coaxial) and Type CATVR-OF (coaxial/optical-fiber). These cables are for installation as specified in Section 800.179(B) of the National Electrical Code, NFPA 70 in vertical runs in a shaft or for vertical runs that penetrate more than one floor. c) GENERAL-PURPOSE CABLES – Type CATV (coaxial) and Type CATV-OF (coaxial/optical-fiber). These cables are general-applications commercial cables for use as specified in Section 800.179(C) of the National Electrical Code, NFPA 70. d) LIMITED-USE CABLES – Type CATVX (coaxial) and Type CATVX-OF (coaxial/optical-fiber). These are limited use cables as specified in Section 800.179(D) of the National Electrical Code, NFPA 70. This Standard does not specify the impedance or other signal-carrying characteristics of these cables. This Standard does not cover tests for the signal-carrying performance of these cables. Armored cables are covered by interlocked metal strip or a smooth or corrugated metal sheath with or without a jacket over the armor. Cables for encasement in concrete, mortar, other masonry, plaster, or the like have metal armor and a jacket over the armor. Cables for direct burial in the earth (see markings in 1.8) are subject to a 1000-pound crushing test. Cables for direct burial are not required to be armored. Cables for direct burial that are armored have a jacket over the armor. All other cables (unarmored, flat or round) have an overall jacket. Some overall jackets incorporate a nonmetallic messenger. A metallic messenger may be joined to the cable jacket by an interconnecting web. Cables of a CATV type do not have a voltage rating. Cables of materials that qualify for temperatures above 60 °C (140 °F) are marked with a temperature rating of 75, 90, 105, 125, 150, 200 °C or 250 °C (167, 194, 221, 257, 302, 392 °F or 482 °F). Temperature marking is not required for cables that qualify for a temperature rating of 60 °C (140 °F). Cables that contain one or more electromagnetic shields in addition to the outer conductors of the coaxial members (these shields are identified as "additional" in 9.1) are not required to be marked to indicate the presence of the additional shielding. A shielded cable that is marked has "shielded" on the tag and either on the overall cable jacket or legible through the jacket. Cables that qualify for exposure to sunlight (720-hour sunlight-resistance test – see 27.1) have the designation "sun res" or "sunlight resistant" on the tag and either on the overall cable jacket or legible through the jacket. Cables that qualify for burial directly in the earth (1000-pound crushing test – see 29.1) have the designation "dir bur", "direct burial", or "for direct burial" on the tag and either on the overall cable jacket or legible through the jacket. Optical performance is not evaluated. Cables with optical fibers are to have a tag marking in accordance with 10.3 and 37.1(d). Where there are conductive parts in an optical-fiber member or in a group of such members, a tag marking [36.1(e)] indicates the presence of these parts. These requirements do not cover antenna-rotator or other coaxial/electrical cables – that is, coaxial cables with additional conductors for electric-light, power, control, non-power-limited fire-alarm, Class 1, Class 2, or Class 3 circuits. Smoke and flame tests are as follows for the cables covered in these requirements: a) PLENUM CABLES – All Type CATVP and Type CATVP-OF cables are tested for smoke and flame characteristics as specified in Smoke and Flame Testing of Plenum Cables, Section 23, which references the National Fire Protection Association Standard Method of Test for Flame Travel and Smoke of Wires and Cables for Use in Air-Handling Spaces, NFPA 262. A cable that complies exhibits a maximum flame-propagation distance that is not greater than 5 ft, 0 in or 152 cm, a peak optical density of smoke produced of 0.50 or less, and an average optical density of smoke produced of 0.15 or less. b) RISER CABLES – Jacketed Type CATVR and Type CATVR-OF cables that comply with the flame-propagation characteristics as specified in Flame Testing of Riser Cables, Section 24, which references the Standard for Test for Flame-Propagation Height of Electrical and Optical-Fiber Cables Installed Vertically in Shafts, UL 1666. c) GENERAL-PURPOSE CABLES – Jacketed Type CATV and Type CATV-OF cables are to comply with one of the two 70,000 Btu/h (20.5 kW) vertical-tray flame tests specified in Alternative Vertical-Tray Flame Tests of General-Purpose Cables, Section 26. The cable manufacturer is to choose one of the following tests: 1) The UL test referenced in 26.1.1 – 26.3.2. These paragraphs apply the test method described as the UL Flame Exposure (smoke measurements are not applicable) in the Standard for Vertical-Tray Fire-Propagation and Smoke-Release Test for Electrical and Optical-Fiber Cables, UL 1685 or the Standard for Wire and Cable Test Methods, UL 2556. 2) The FT4/IEEE 1202 test referenced in 26.1.1 and 26.4.1. These paragraphs apply the test method described as the FT4/IEEE 1202 Type of Flame Exposure (smoke measurements are not applicable) in the Standard for Vertical-Tray Fire-Propagation and Smoke-Release Test for Electrical and Optical-Fiber Cables, UL 1685 or the Standard for Wire and Cable Test Methods, UL 2556. A cable that complies is eligible to be marked "FT4/IEEE 1202" or "FT4" on the surface or on a marker tape as indicated in 36.1(h). d) LIMITED-USE CABLES – All Type CATVX and Type CATVX-OF cables are subjected to the VW-1 flame test specified in VW-1 (Vertical-Specimen) Flame Test of Limited-Use Cables, Section 25, which references the test method described as the VW-1 (Vertical-Specimen) Flame Test in the Standard for Wire and Cable Test Methods, UL 2556. These cables are not marked "VW-1". These requirements do not specify or test for the electrostatic/electromagnetic performance of a shield.



