UL 121303-2020 PDF
Standard For Safety Guide for Use of Detectors for Flammable Gases
- 3A-3-A Sanitary Standards
- 9000-9000 Store
- A3-Association for Advancing Automation
- A4A-Airlines for America
- AA-The Aluminum Association
- AAMI-Association for the Advancement of Medical Instrumentation
- AASHTO-American Association of State Highway and Transportation Officials
- AATCC-American Association of Textile Chemists and Colorists
- ABCB-Australian Building Codes Board
- ABMA-American Bearing Manufacturers Association
- ABMA-BOILER-American Boiler Manufacturers Association
- ACC-American Chemistry Council
- ACGIH-American Conference of Governmental Industrial Hygienists
- ACI-American Concrete Institute
- AEIC-Association of Edison Illuminating Companies
- AES-Audio Engineering Society
- AFCEN-French Association
- AGA-American Gas Association
- AGMA-American Gear Manufacturers Association
- AHAM-Association of Home Appliance Manufacturers
- AHP-American Herbal Pharmacopoeia
- AHRI-Air-Conditioning, Heating, and Refrigeration Institute (formerly ARI)
- AIA-Aerospace Industries Association
- AIAA-American Institute of Aeronautics and Astronautics
- AICHE-American Institute of Chemical Engineers
- AIHA-American Industrial Hygiene Association
- AISC-American Institute of Steel Construction
- ALI-American Ladder Institute
- ALPEMA-Aluminium Plate-Fin Heat Exchanger Manufacturers' Association
- AMCA-Air Movement and Control Association
- ANS-American Nuclear Society
- ANSI-American National Standards Institute
- ANSI/ANSLG-American National Standards Institute / American National Standard Lighting Group
- ANSI/NEMA-American National Standards Institute / National Electrical Manufacturers Association
- ANSI/TCNA-Tile Council of North America, Inc.
- ANSI/UAMA-Unified Abrasives Manufacturers' Association
- API-American Petroleum Institute
- APWA-American Public Works Association
- AREMA-American Railway Engineering and Maintenance-of-Way Association
- ARINC-ARINC Industry Activities
- ARMY-United States Army Publication
- AS-Standards Australia
- ASA-Acoustical Society of America Standards
- ASABE-American Society of Agricultural and Biological Engineers (Formerly ASAE)
- ASCE-American Society of Civil Engineers
- ASD-STAN prEN-ASD-STAN Standardization
- ASHE-American Society for Healthcare Engineering
- ASHRAE-American Society of Heating, Refrigerating, and Air Conditioning Engineers
- ASIS-ASIS International
- ASM-ASM International
- ASME-ASME International
- ASNT-The American Society for Nondestructive Testing
- ASQ-American Society for Quality
- ASSE (Plumbing)-American Society of Sanitary Engineering
- ATIS-The Alliance for Telecommunications Industry Solutions
- ASTM-ASTM International
- AVIXA-Audiovisual and Integrated Experience Association
- AWC-American Wood Council
- AWI-Architectural Woodwork Institute
- AWS-American Welding Society
- AWWA-American Water Works Association
- AWPA-American Wood Protection Association
- B11-B11 Standards, Inc.
- BHMA-Builders Hardware Manufacturers Association
- BICSI-BICSI, A Telecommunications Association
- BioWorld-Thomson Reuters BioWorld
- BMI-Battelle - Metallic Materials Properties Development and Standardization (MMPDS)
- BS-BSI Group
- CAN/CGSB-Canadian General Standards Board
- CAN/ULC-Underwriters Laboratories of Canada
- CEI-Comitato Elettrotecnico Italiano
- CFR-Code of Federal Regulations
- CGA-Compressed Gas Association
- CIE-Commission Internationale de L'Eclairage
- CII-Construction Industry Institute
- CISPR-International Special Committee on Radio Interference
- CLSI-Clinical and Laboratory Standards Institute
- CMAA-Crane Manufacturers Association of America, Inc.
- CRANE-Crane Co.
- CRSI-Concrete Reinforcing Steel Institute
- CSA-Canadian Standards Association
- CTA-Consumer Technology Association (Formerly CEA)
- CTI-Cooling Technology Institute
- DANSK-Dansk Standard
- DID-Data Item Description
- DIN-Deutsches Institut Fur Normung E.V. (German National Standard)
- DNV-DNV
- DOD-Department of Defense
- DOXPUB-Doxpub, Inc.
- DVS-DEUTSCHER VERBAND FÜR SCHWEISSEN UND VERWANDTE VERFAHREN E.V.
- ECIA-Electronic Components Industry Association
- EEC-European Union Directives
- EEMUA-Engineering Equipment and Materials Users Association
- ESD-EOS/ESD Association, Inc.
- ETSI-European Telecommunications Standards Institute
- FCI-Fluid Controls Institute
- ISO-International Organization for Standardization
- ISO/IEC/IEEE-International Organization for Standardization / International Electrotechnical Commission / Institute of Electrical and Electronics Engineers
- ISPE-International Society for Pharmaceutical Engineering
- FED-Federal Specifications and Standards
- ISTA-International Safe Transit Association
- ISUZU-Isuzu Motors Ltd.
- FM Approvals-FM Approvals
- JEDEC-JEDEC Solid State Technology Association
- JSA-Japanese Standards Association (JIS Standards)
- LIA-Laser Institute of America
- FORD-Ford Motor Company
- MBMA-Metal Building Manufacturers Association
- MCGRAW-HILL-McGraw-Hill Publishing Company
- FRPI-Fiberglass Reinforced Plastics Institute, Inc.
- MIL-Military Specifications and Standards
- MPIF-Metal Powder Industries Federation
- MPMA-Motion + Power Manufacturers Alliance (MPMA) (Formerly AGMA & ABMA)
- GMW-General Motors Worldwide
- MSS-Manufacturers Standardization Society of the Valve and Fittings Industry
- NAAMM-National Association of Architectural Metal Manufacturers
- GPA-GPA Midstream Association
- NACE-National Association of Corrosion Engineers
- NADCA-National Air Duct Cleaners Association
- NAS-Aerospace Industries Association - National Aerospace Standard
- HEI-Heat Exchange Institute
- NASA-National Aeronautics and Space Administration
- NBBI-The National Board of Boiler and Pressure Vessel Inspectors
- NCSL-National Conference of Standards Laboratories International
- HFES-Human Factors and Ergonomics Society
- NECA-National Electrical Contractors Association
- RTCA-RTCA, Inc.
- HI-Hydraulic Institute
- NEMA-National Electrical Manufacturers Association
- NETA-InterNational Electrical Testing Association
- NFPA (Fire)-National Fire Protection Association
- HIR-H.I.R. Technical Services
- NFPA (Fluid)-National Fluid Power Association
- NFSI-National Floor Safety Institute
- HPS-Health Physics Society
- NGA-National Glass Association
- NISO-National Information Standards Organization
- NORSOK-NORSOK
- I3A-International Imaging Industry Association
- NRC-National Research Council Canada
- NSC-Natural Stone Council
- IADC-International Association of Drilling Contractors
- NSF-NSF International
- NZS-Standards New Zealand
- OPEI-Outdoor Power Equipment Institute
- IAPMO-International Association of Plumbing and Mechanical Officials
- PCI-Precast/Prestressed Concrete Institute
- PDA-Parenteral Drug Association
- IATA-International Air Transport Association
- PEI-Petroleum Equipment Institute
- PFI-Pipe Fabrication Institute
- PIA-Parachute Industry Association
- ICAO-International Civil Aviation Organization
- PIP-Process Industry Practices
- PPI-Plastics Pipe Institute
- ICC-International Code Council
- PTI-Post-Tensioning Institute
- ICEA-Insulated Cable Engineers Association
- ICML-International Council for Machinery Lubrication
- IEC-International Electrotechnical Commission
- IEEE-Institute of Electrical and Electronics Engineers
- IES-Illuminating Engineering Society
- IEST-Institute of Environmental Sciences and Technology
- IFI-Industrial Fasteners Institute
- IICRC-Institute of Inspection, Cleaning and Restoration Certification
- INCITS-InterNational Committee for Information Technology Standards (formerly NCITS)
- INTERN-International Motors, LLC (Formerly NAVISTAR)
- IPC-IPC by Global Electronics Association
- ISA-International Society of Automation
- ISEA-International Safety Equipment Association
- SAE-SAE International
- SAIA-Scaffold & Access Industry Association
- SCTE-Society of Cable Telecommunication Engineers
- SDI-Steel Door Institute
- SES-The Society for Standards Professionals
- SIA-Security Industry Association
- SJI-Steel Joist Institute
- SMACNA-Sheet Metal and Air Conditioning Contractors' National Association
- SME-Society of Manufacturing Engineers
- SMPTE-Society of Motion Picture and Television Engineers
- SN EN-Standards Norway EN
- SPC-Standards Press of China
- SPI-Society of the Plastics Industry
- SSPC-Society for Protective Coatings
- STI/SPFA-Steel Tank Institute/Steel Plate Fabricators Association
- TAPPI-Technical Association of the Pulp and Paper Industry
- TCIA-Tree Care Industry Association
- TEMA-Tubular Exchanger Manufacturers Association
- THHILL-TH Hill Associates, Inc.
- TIA-Telecommunications Industry Association
- TMS-The Masonry Society
- UL-Underwriters Laboratories
- ULC-Underwriters Laboratories of Canada
- UNE-Asociación Española de Normalización
- WILEY-John Wiley and Sons
- WRC-Welding Research Council, Inc.
- WSPC-World Scientific Publishing Co.
- X9-Accredited Standards Committee X9 Incorporated
Your shopping cart is empty!
Product Description
The intent of this document is to provide recommendation for use of detectors for flammable gases, which includes fixed, portable and transportable equipment types, to provide protection from explosion or fires by minimizing the possibility of an accumulation of flammable gases reaching ignitable levels and initiating mitigative actions based upon defined gas concentration limits. There are three independent applications for use of gas detection equipment within hazardous locations: personnel and property protection, classified area surveillance, and supplemental protection for the use of otherwise unsuitable equipment. Detectors for flammable gases for personnel and property protection provides ability to work in hazardous (classified) locations, alert user to unsafe conditions, and take mitigative actions as appropriate. It is the intent of this document to compile and provide techniques for proper use of this equipment to achieve personnel and property protection. Area monitoring gas detection equipment provides surveillance of a hazardous (classified) location to demonstrate that levels of flammable gases are below the accepted levels of ignitable concentrations. When exposure limits are exceeded, alarm and notification are initiated to prompt evacuation of personnel from the affected location. Also, when exposure limits are exceeded and ventilation techniques are not effective, then repair of equipment is warranted, or a shutdown action will be required. This prevents further loss of containment for the affected process and that the electrical equipment not suitable for use in the flammable atmosphere be de-energized. It is the intent of this document to compile and provide techniques for the use of detectors for flammable gases to monitor and control sources of flammable gas release as a means of process safety management. In addition, supplemental area protection is provided by use of gas detection equipment to allow the use of otherwise unsuitable electrical equipment within hazardous (classified) locations. Criteria are developed to establish flammable gas levels to initiate alarms, initiate increase in ventilation rates and to initiate shutdown of processes to shut off the flow of flammable gas that has breached containment and to de-energize all unsuitable electrical equipment. It is the intent of this document to compile and provide techniques for the use of flammable gas equipment to monitor and control sources of flammable gas release into the atmosphere within designated spaces. It is also the intent that these products and techniques be adapted by industries and used with processes that have historically not employed flammable gas detection. Detectors for flammable gases as described in this document may be applied as stand-alone sensor/controllers or may be incorporated with or into another system such as, Basic Process and Control System (BPCS), Safety Instrumented System (SIS) or Fire and Gas System that may be employed in an industrial facility. When ventilation rates are to be controlled by the various responses of the flammable gas detection and control devices, there may also be interaction with the HVAC control system or devices. NOTE 1: Applicable Detectors for flammable gases performance standards include FM 60079-29-1/UL 60079-29-1 and FM 60079-29-4/UL 60079-29-4. For the purpose of this document flammable gases include flammable gases and vapors. This document provides guidance on personnel and property protection by the use of detectors for flammable gases as defined within the following specified documents. • ANSI/NFPA 72 for all installations. • Title 29 Code of Federal Regulations 1910.119(k) OSHA regulations to support the hot work permit. This document provides guidance on the use of a flammable gas detection system as a means of protection in industrial establishments with restricted public access and where the conditions of maintenance and supervision allow only qualified persons service the installation as defined within the following specified documents: • ANSI/NFPA 70 (NEC) where for specific applications, electrical equipment that would not otherwise be permitted in the hazardous (classified) location may be used in conjunction with detectors for flammable gases; • API RP 500 and API RP 505 for the determination of ventilation required to provide adequate dilution of the detected flammable gas to prevent the possibility of ignition; • API RP 14F and API RP 14FZ also provide guidance on the use of gas detection as a protection technique. Documents other than API RP 500 and RP 505 that describe area classification techniques are ANSI/NFPA 497 and ANSI/ISA 60079-10-1. Application of flammable gas detection and control as described in this document can provide additional protection from fire and explosion over typical electrical protection techniques by risk reduction methods. Industries that use these and other area classification documents can benefit by application of the techniques and criteria presented in this document. NOTE 2: Where mandatory text is provided in this Technical Report, the basis of the mandatory text is derived directly from referenced standards. This document provides guidance on the use of flammable gas detection as a supplement to other explosion protection in adequately ventilated spaces. This document provides guidance on the use of detectors for flammable gases for monitoring classified areas for low LFL level of flammable gas to initiate maintenance actions to locate and repair leaks in addition to providing alarm to notify personnel for evacuation.



