UL 13-2015 PDF
UL Standard for Safety Power-Limited Circuit Cables
- 3A-3-A Sanitary Standards
- 9000-9000 Store
- A3-Association for Advancing Automation
- A4A-Airlines for America
- AA-The Aluminum Association
- AAMI-Association for the Advancement of Medical Instrumentation
- AASHTO-American Association of State Highway and Transportation Officials
- AATCC-American Association of Textile Chemists and Colorists
- ABCB-Australian Building Codes Board
- ABMA-American Bearing Manufacturers Association
- ABMA-BOILER-American Boiler Manufacturers Association
- ACC-American Chemistry Council
- ACGIH-American Conference of Governmental Industrial Hygienists
- ACI-American Concrete Institute
- AEIC-Association of Edison Illuminating Companies
- AES-Audio Engineering Society
- AFCEN-French Association
- AGA-American Gas Association
- AGMA-American Gear Manufacturers Association
- AHAM-Association of Home Appliance Manufacturers
- AHP-American Herbal Pharmacopoeia
- AHRI-Air-Conditioning, Heating, and Refrigeration Institute (formerly ARI)
- AIA-Aerospace Industries Association
- AIAA-American Institute of Aeronautics and Astronautics
- AICHE-American Institute of Chemical Engineers
- AIHA-American Industrial Hygiene Association
- AISC-American Institute of Steel Construction
- ALI-American Ladder Institute
- ALPEMA-Aluminium Plate-Fin Heat Exchanger Manufacturers' Association
- AMCA-Air Movement and Control Association
- ANS-American Nuclear Society
- ANSI-American National Standards Institute
- ANSI/ANSLG-American National Standards Institute / American National Standard Lighting Group
- ANSI/NEMA-American National Standards Institute / National Electrical Manufacturers Association
- ANSI/TCNA-Tile Council of North America, Inc.
- ANSI/UAMA-Unified Abrasives Manufacturers' Association
- API-American Petroleum Institute
- APWA-American Public Works Association
- AREMA-American Railway Engineering and Maintenance-of-Way Association
- ARINC-ARINC Industry Activities
- ARMY-United States Army Publication
- AS-Standards Australia
- ASA-Acoustical Society of America Standards
- ASABE-American Society of Agricultural and Biological Engineers (Formerly ASAE)
- ASCE-American Society of Civil Engineers
- ASD-STAN prEN-ASD-STAN Standardization
- ASHE-American Society for Healthcare Engineering
- ASHRAE-American Society of Heating, Refrigerating, and Air Conditioning Engineers
- ASIS-ASIS International
- ASM-ASM International
- ASME-ASME International
- ASNT-The American Society for Nondestructive Testing
- ASQ-American Society for Quality
- ASSE (Plumbing)-American Society of Sanitary Engineering
- ATIS-The Alliance for Telecommunications Industry Solutions
- ASTM-ASTM International
- AVIXA-Audiovisual and Integrated Experience Association
- AWC-American Wood Council
- AWI-Architectural Woodwork Institute
- AWS-American Welding Society
- AWWA-American Water Works Association
- AWPA-American Wood Protection Association
- B11-B11 Standards, Inc.
- BHMA-Builders Hardware Manufacturers Association
- BICSI-BICSI, A Telecommunications Association
- BioWorld-Thomson Reuters BioWorld
- BMI-Battelle - Metallic Materials Properties Development and Standardization (MMPDS)
- BS-BSI Group
- CAN/CGSB-Canadian General Standards Board
- CAN/ULC-Underwriters Laboratories of Canada
- CEI-Comitato Elettrotecnico Italiano
- CFR-Code of Federal Regulations
- CGA-Compressed Gas Association
- CIE-Commission Internationale de L'Eclairage
- CII-Construction Industry Institute
- CISPR-International Special Committee on Radio Interference
- CLSI-Clinical and Laboratory Standards Institute
- CMAA-Crane Manufacturers Association of America, Inc.
- CRANE-Crane Co.
- CRSI-Concrete Reinforcing Steel Institute
- CSA-Canadian Standards Association
- CTA-Consumer Technology Association (Formerly CEA)
- CTI-Cooling Technology Institute
- DANSK-Dansk Standard
- DID-Data Item Description
- DIN-Deutsches Institut Fur Normung E.V. (German National Standard)
- DNV-DNV
- DOD-Department of Defense
- DOXPUB-Doxpub, Inc.
- DVS-DEUTSCHER VERBAND FÜR SCHWEISSEN UND VERWANDTE VERFAHREN E.V.
- ECIA-Electronic Components Industry Association
- EEC-European Union Directives
- EEMUA-Engineering Equipment and Materials Users Association
- ESD-EOS/ESD Association, Inc.
- ETSI-European Telecommunications Standards Institute
- FCI-Fluid Controls Institute
- ISO-International Organization for Standardization
- ISO/IEC/IEEE-International Organization for Standardization / International Electrotechnical Commission / Institute of Electrical and Electronics Engineers
- ISPE-International Society for Pharmaceutical Engineering
- FED-Federal Specifications and Standards
- ISTA-International Safe Transit Association
- ISUZU-Isuzu Motors Ltd.
- FM Approvals-FM Approvals
- JEDEC-JEDEC Solid State Technology Association
- JSA-Japanese Standards Association (JIS Standards)
- LIA-Laser Institute of America
- FORD-Ford Motor Company
- MBMA-Metal Building Manufacturers Association
- MCGRAW-HILL-McGraw-Hill Publishing Company
- FRPI-Fiberglass Reinforced Plastics Institute, Inc.
- MIL-Military Specifications and Standards
- MPIF-Metal Powder Industries Federation
- MPMA-Motion + Power Manufacturers Alliance (MPMA) (Formerly AGMA & ABMA)
- GMW-General Motors Worldwide
- MSS-Manufacturers Standardization Society of the Valve and Fittings Industry
- NAAMM-National Association of Architectural Metal Manufacturers
- GPA-GPA Midstream Association
- NACE-National Association of Corrosion Engineers
- NADCA-National Air Duct Cleaners Association
- NAS-Aerospace Industries Association - National Aerospace Standard
- HEI-Heat Exchange Institute
- NASA-National Aeronautics and Space Administration
- NBBI-The National Board of Boiler and Pressure Vessel Inspectors
- NCSL-National Conference of Standards Laboratories International
- HFES-Human Factors and Ergonomics Society
- NECA-National Electrical Contractors Association
- RTCA-RTCA, Inc.
- HI-Hydraulic Institute
- NEMA-National Electrical Manufacturers Association
- NETA-InterNational Electrical Testing Association
- NFPA (Fire)-National Fire Protection Association
- HIR-H.I.R. Technical Services
- NFPA (Fluid)-National Fluid Power Association
- NFSI-National Floor Safety Institute
- HPS-Health Physics Society
- NGA-National Glass Association
- NISO-National Information Standards Organization
- NORSOK-NORSOK
- I3A-International Imaging Industry Association
- NRC-National Research Council Canada
- NSC-Natural Stone Council
- IADC-International Association of Drilling Contractors
- NSF-NSF International
- NZS-Standards New Zealand
- OPEI-Outdoor Power Equipment Institute
- IAPMO-International Association of Plumbing and Mechanical Officials
- PCI-Precast/Prestressed Concrete Institute
- PDA-Parenteral Drug Association
- IATA-International Air Transport Association
- PEI-Petroleum Equipment Institute
- PFI-Pipe Fabrication Institute
- PIA-Parachute Industry Association
- ICAO-International Civil Aviation Organization
- PIP-Process Industry Practices
- PPI-Plastics Pipe Institute
- ICC-International Code Council
- PTI-Post-Tensioning Institute
- ICEA-Insulated Cable Engineers Association
- ICML-International Council for Machinery Lubrication
- IEC-International Electrotechnical Commission
- IEEE-Institute of Electrical and Electronics Engineers
- IES-Illuminating Engineering Society
- IEST-Institute of Environmental Sciences and Technology
- IFI-Industrial Fasteners Institute
- IICRC-Institute of Inspection, Cleaning and Restoration Certification
- INCITS-InterNational Committee for Information Technology Standards (formerly NCITS)
- INTERN-International Motors, LLC (Formerly NAVISTAR)
- IPC-IPC by Global Electronics Association
- ISA-International Society of Automation
- ISEA-International Safety Equipment Association
- SAE-SAE International
- SAIA-Scaffold & Access Industry Association
- SCTE-Society of Cable Telecommunication Engineers
- SDI-Steel Door Institute
- SES-The Society for Standards Professionals
- SIA-Security Industry Association
- SJI-Steel Joist Institute
- SMACNA-Sheet Metal and Air Conditioning Contractors' National Association
- SME-Society of Manufacturing Engineers
- SMPTE-Society of Motion Picture and Television Engineers
- SN EN-Standards Norway EN
- SPC-Standards Press of China
- SPI-Society of the Plastics Industry
- SSPC-Society for Protective Coatings
- STI/SPFA-Steel Tank Institute/Steel Plate Fabricators Association
- TAPPI-Technical Association of the Pulp and Paper Industry
- TCIA-Tree Care Industry Association
- TEMA-Tubular Exchanger Manufacturers Association
- THHILL-TH Hill Associates, Inc.
- TIA-Telecommunications Industry Association
- TMS-The Masonry Society
- UL-Underwriters Laboratories
- ULC-Underwriters Laboratories of Canada
- UNE-Asociación Española de Normalización
- WILEY-John Wiley and Sons
- WRC-Welding Research Council, Inc.
- WSPC-World Scientific Publishing Co.
- X9-Accredited Standards Committee X9 Incorporated
Your shopping cart is empty!
Product Description
These requirements cover 60 – 250°C (140 – 482°F) single- and multiple-conductor power-limited circuit cables for use as fixed wiring within buildings (some are also marked for direct burial) principally for Class 3 and Class 2 circuits as described in Article 725 and other applicable parts of the National Electrical Code (NEC). Cables covered by these requirements are: a) Types CL3P and CL2P (plenum cables), b) Types CL3R and CL2R (riser cables), c) Types CL3 and CL2 (commercial cables for other than plenum, riser, or tray uses), d) Types CL3X and CL2X (cables for limited use), and e) Type PLTC (cable for non-plenum and non-riser Class 3 and Class 2 circuits in general and in trays). Cables for Class 3 circuits are rated for 300 volts but are not so marked. Cables for Class 2 circuits do not have a voltage rating. See 47.1(h). A cable that contains one or more electromagnetic shields may be surface marked or have a marker tape to indicate that it is "shielded". A cable that contains one or more optical-fiber members has "-OF" supplementing the type letters and is marked in accordance with 48.1(d). A cable may consist of or contain one or more coaxial members. The overall jacket on a cable that has "sun res" or "sunlight resistant" in a surface marking or on a marker tape complies with a 720-h sunlight-resistance test. The overall jacket on all Type PLTC cable is required to comply with this 720-h test, so Type PLTC cable may be marked "sun res" or "sunlight resistant" but is not required to be so marked. A cable that has "dir bur", "direct burial", or "for direct burial" in a surface marking or on a marker tape complies with a 1000-lbf crushing test. Direct-burial cable with wire armor, a metal braid, interlocked metal armor, or a smooth or corrugated metal sheath has a jacket over the metal covering. Smoke and fire considerations are as follows for the cables covered in these requirements: a) TYPE CL3P and CL2P CABLES – Cables that are intended for installation in accordance with section 725.82 (A) of the National Electrical Code, ANSI/NFPA 70, in a duct, plenum, or other space used to transport environmental air without the cables being enclosed in a raceway in that space are to be tested for smoke and flame characteristics in accordance with the National Fire Protection Association Standard Method of Test for Flame Travel and Smoke of Wires and Cables for Use in Air-Handling Spaces, ANSI/NFPA 262. A cable that complies exhibits a maximum flame-propagation distance that is not greater than 5 ft, 0 in or 152 cm, a peak optical density of smoke produced of 0.50 or less (32 percent light transmission), and an average optical density of smoke produced of 0.15 or less. b) TYPE CL3R and CL2R CABLES – Cables that are intended for use in vertical runs in a shaft, or for installations in which the cables penetrate more than one floor, as specified in Section 725.82 (B) of the National Electrical Code, ANSI/NFPA 70, are to be tested for flame-propagation characteristics in accordance with the Standard for Test for Flame-Propagation Height of Electrical and Optical-Fiber Cables Installed Vertically in Shafts, UL 1666. A cable that complies has a flame-propagation height less than 12 ft, 0 in or 366 cm and temperatures are 850.0°F (454.4°C) or less at a height of 12 ft, 0 in or 366 cm. c) TYPE CL3 and CL2 CABLES – Type CL3 and CL2 general-use cables comply with a 70,000 Btu/h (20.5 kW) vertical-tray flame test. The cable manufacturer chooses one of the following tests: 1) THE UL TEST REFERENCED IN 28.2.1 – This paragraph applies the test method described as the UL Flame Exposure (smoke measurements are not applicable) in the Standard for Vertical-Tray Fire-Propagation and Smoke-Release Test for Electrical and Optical-Fiber Cables, UL 1685, to cable that is surface marked or designated by a marker tape as "CL3" or "CL2". For compliance, this test damages less than 8 feet (244 cm) of cable. 2) THE FT4/IEEE 1202 TEST REFERENCED IN 28.3.1 – This paragraph applies the test method described as the FT4/IEEE 1202 Type of Flame Exposure (smoke measurements are not applicable) in the Standard for Vertical-Tray Fire-Propagation and Smoke-Release Test for Electrical and Optical-Fiber Cables, UL 1685. This test differs from the UL test in loading (more cables are used, with small cables bundled, and the spacing between cables is limited), burner angle, and failure criterion. For compliance, this test damages less than 150 cm (59 in) of cable. A cable that complies either is not marked or it bears the designation "FT4/IEEE 1202" or "FT4" legible on or through the outer surface or on a marker tape [see marking in 47.1(i)]. d) TYPE CL3X and CL2X CABLES – Type CL3X and CL2X cables comply with the VW-1 vertical-specimen flame test. The cable is not marked "VW-1". e) TYPE PLTC CABLE – Type PLTC tray cable complies with a 70,000 Btu/h (20.5 kW) vertical-tray flame test. The cable manufacturer chooses the test in (c)(1) or (c)(2). This test is applied to cable that is surface marked or designated by a marker tape as "PLTC". The overall jacket on Type PLTC cable is a "gas/vapor-tight continuous sheath" in the sense discussed in sections 501.15 (D) and 501.15 (E) of the National Electrical Code, ANSI/NFPA 70. Cables that are surface marked "-ER" are for use as exposed runs between a cable tray and utilization equipment where the cables are continuously supported and protected against physical damage using mechanical protection such as struts, angles, or channel. With certain exceptions, as noted in 1.9, Type CL3X and CL2X cables are required by the NEC to be used with protection such as raceway. The Type CL3 and CL2 and other cables covered in these requirements that are not required by the NEC to be used in raceway are capable of use without the physical protection of raceway but may be pulled into conduit or installed in other raceway. Type CL3X and CL2X cables are limited by the NEC to use in unconcealed spaces in which the exposed length of cable does not exceed 10 ft or 3.05 m, and in raceway. These NEC limitations do not apply to Type CL3X and CL2X cables that are smaller in diameter than 0.25 in or 6.35 mm and are used in a one-, two-, or multi-family dwelling. These requirements do not cover cables that contain conductors for electric-light, power, or Class 1 circuits. These requirements do not cover optical-fiber cables that do not contain any electrical conductors. These requirements do not cover communication cables (see the Standard for Communications Cables, UL 444) or cables for power-limited fire-alarm circuits (see the Standard for Cables for Power-Limited Fire- Alarm Circuits, UL 1424). These requirements do not cover vault-lacing cable, which is for use in concrete as part of a theft-alarm system. These requirements do not cover the optical or other performance of any optical-fiber member or group of such members. See 8.3.



