IEC 60034-18-32 CMV-2022 PDF

IEC 60034-18-32 CMV-2022 PDF

Rotating electrical machines-Part 18-32: Functional evaluation of insulation systems (Type II)-Electrical endurance qualification procedures for form-wound windings (Commented Version)

$201.76 $403.52 -50%
Product Code: IEC 60034-18-32 CMV
Stock In Stock
Edition: 2.0
Published: 01/2022
Number of Pages: 90
File Size: 1 file, 2.2 MB

Available Options

Product Description

Rotating electrical machines – Part 18-32: Functional evaluation of insulation systems (Type II) – Electrical endurance qualification procedures for form-wound windings (Commented Version)

Introduction: IEC 60034-18-1 presents general principles for the evaluation of insulation systems used in rotating electrical machines. This document deals exclusively with insulation systems for form-wound windings (Type II) and concentrates on electrical functional evaluation. In IEC 60034-18-42, tests are described for qualification of Type II insulation systems in voltage-source converter operation. These insulation systems are generally used in rotating machines which have form-wound windings, mostly rated above 700 V r.m.s. The two standards IEC 60034-18-41 and IEC 60034-18-42 separate the systems into those which are not expected to experience partial discharge activity within specified conditions in their service lives (Type I), and those which are expected to experience and withstand partial discharge activity in any part of the insulation system throughout their service lives (Type II).

Scope: This part of IEC 60034-18 describes test qualification procedures for the evaluation of electrical endurance of insulation systems for use in a.c. or d.c. rotating electrical machines using form- wound windings energized with sinusoidal power frequency voltage. The test procedures for the main wall insulation are comparative in nature, such that the performance of a candidate insulation system is compared to that of a reference insulation system with proven service experience. The test procedures are principally directed at the insulation systems in air-cooled machines but may also be used for evaluating parts of the insulation systems in hydrogen cooled machines. Note that the qualification procedures of inverter duty insulation systems for form-wound windings can be found in IEC 60034-18-42. If no reference system is available, the diagram in Annex A is available for use. The qualification procedures of inverter duty insulation system for form-wound windings can be found in IEC 60034-18-42 or IEC 60034-18-41. A new and informative test procedure for the stress control system is introduced and defined in Annex B. 2

Contents:

  • FOREWORD
  • INTRODUCTION
  • Scope

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
IEC 60034-18-32 CMV-2022 PDF

IEC 60034-18-32 CMV-2022 PDF

$201.76 $403.52