Rotating electrical machines – Part 2-3: Specific test methods for determining losses and efficiency of converter-fed AC motors
Introduction: The objective of this document is to define test methods for determining total losses including additional high frequency motor losses and efficiency of converter-fed motors. Additional high frequency losses appear in addition to the losses on nominally sinusoidal power supply as determined by the methods of IEC 60034-2-1. Results determined according to this document are intended to allow comparison of losses and efficiency of different motors if fed by converters. Furthermore, the document gives seven standardized operating points to characterize the development of losses and efficiency across the whole torque/speed range. An interpolation procedure is provided to calculate losses and efficiency at any operating point (torque, speed). In power-drive systems (PDS), the motor and the frequency converter are often manufactured by different suppliers. Motors of the same design are produced in large quantities. They may be operated from the grid or from frequency converters of many different types, supplied by many different manufacturers. The individual converter properties (switching frequency, DC link voltage level, etc.) will also influence the system efficiency. As it is impractical to determine motor losses for every combination of motor, frequency converter, connection cable, output filter and parameter settings, this document describes a limited number of approaches, depending on the voltage level and the rating of the motor under test. The losses determined with the com
Scope: This part of IEC 60034 specifies test methods and an interpolation procedure for determining losses and efficiencies of converter-fed motors. The motor is then part of a variable frequency power drive system (PDS) as defined in IEC 61800-9-2. Applying the approach of the comparable converter, the motor efficiency determined by use of this document is applicable for comparison of different low voltage motor designs only. The comparable converter approach is not applicable to medium voltage motors. This document also specifies procedures to determine motor losses at any load point (torque, speed) within the constant flux range (constant torque range, base speed range), the field weakening range and the overload range based on determination of losses at seven standardized load points. This procedure is applicable to any variable speed AC motor (induction and synchronous) rated according to IEC 60034-1 for operation on a variable frequency and variable voltage power supply.
Contents:
- FOREWORD
- INTRODUCTION
- Scope