Rotating electrical machines - Part 30-1: Efficiency classes of line operated AC motors (IE code) (Commented Version)
Introduction: This first part of the IEC 60034-30 series, IEC 60034-30-1, provides for the global harmonization of energy efficiency classes of electric motors. It deals with all kinds of electric motors that are rated for line operation (including starting at reduced voltage). This includes all either 50 Hz or 60 Hz, or both single- and three-phase low voltage induction motors, regardless of their rated voltage and frequency, as well as line-start permanent-magnet synchronous motors. The second part of this standard series (IEC 60034-30-2) will be is prepared for motors rated for variable voltage and frequency supply, such as synchronous motors. The second part will also provide for harmonic voltage losses in motors capable of line operation when fed by frequency converters. IEC 60034-30-1 widens the product range covered in the first edition of IEC 60034-30 significantly. The power range has been expanded (starting at 0,12 kW and ending at 1 000 kW). All technical constructions of electric motors are covered as long as they are rated for on- line operation and not just three-phase, cage-induction motors as in the first edition. The IE4 class is newly included in this standard. The informative definition of IE4, which was previously included in IEC/TS 60034-31:2010, is therefore outdated. The new class IE5 is not yet defined in detail but is envisaged for potential products in a future edition of the standard. This second edition of IEC 60034-30-1 introduces a new efficiency class, IE5. I
Scope: This part of IEC 60034 specifies efficiency classes for single-speed electric motors that are rated in accordance with IEC 60034-1 or IEC 60079-0 and are rated for operation on a sinusoidal either 50 Hz or 60 Hz, or both voltage supply. The motors within this document: have a rated power PN from 0,12 kW to 1 000 kW; have a rated voltage UN above from 50 V up to and including 1 000 V; have 2, 4, 6 or 8 poles; are capable of continuous operation at their rated power with a temperature rise within the specified insulation temperature class; NOTE 1 Most motors covered by this document are rated for duty type S1 (continuous duty). However, some motors that are rated for other duty cycles are still capable of continuous operation at their rated power, and these motors are also covered by this document. are marked with any ambient temperature within the range of –20 –30 °C 5 to +60 °C; NOTE 2 The rated efficiency and efficiency classes are based on 25 °C ambient temperature in accordance with IEC 60034-2-1. NOTE 3 Motors exclusively rated for temperatures outside the range – 20 –30 °C and +60 °C are considered to be of special construction and are consequently excluded from this document. NOTE 4 Smoke extraction motors with a temperature class of up to and including 400 °C are covered by this document. are marked with an altitude up to 4 000 m above sea level. NOTE 5 The rated efficiency and efficiency class are based on a rating for altitudes up to 1 000 m above sea level. This document establishes a set of limit nominal efficiency values based on supply frequency, number of poles and motor output power. No distinction is made between motor technologies, supply voltage or motors with increased insulation designed specifically for converter operation even though these not all motor technologies may not all be are capable of reaching the higher efficiency classes (see Table 1). This makes different motor technologies fully comparable with respect to their energy efficiency potential. NOTE 6 Regulators should consider the above constraints when assigning national minimum energy-efficiency performance standards (MEPS) with respect to any particular type of motor. 6 The ef
Contents:
- FOREWORD
- INTRODUCTION
- Scope