Power transformers – Part 6: Reactors
Introduction: This part of IEC 60076 is intended to provide the basis for the specification and testing of the types of reactor given in the scope. The document also gives some important information on certain reactor applications to aid the preparation of a reactor specification. Wherever possible, references to technical Clauses in the other parts of IEC 60076 which are relevant to power transformers have been made. However, because reactors have some fundamental differences to transformers there are special considerations that apply to the specification, testing and application of reactors. These are included in this part of IEC 60076. Clauses 1 to 6 form the general parts of the document, which apply to all types of reactor. Clauses 7 to 12 deal individually with each different type of reactor. Generally, only one of the Clauses 7 to 12 will apply to a specific reactor. This part of IEC 60076 has more than one definition Subclause. The general definitions given in Clause 3 apply to the whole document. Each of the Clauses 7 to 12 dealing with a certain type of reactor includes a definition Subclause relevant and applying only to that Clause. Clauses 7 to 12 have been given a uniform structure. Within this structure, the Rating Subclause sets out the minimum information that a purchaser shall supply with the reactor specification. The test Subclause in each Clause defines the relevant tests that can be applied to that particular type of reactor and may include some additional items that
Scope: This part of IEC 60076 applies to the following types of reactors: shunt reactors; series reactors including current-limiting reactors, neutral-earthing reactors, power flow control reactors, motor starting reactors, arc-furnace series reactors; filter (tuning) reactors; capacitor damping reactors; capacitor discharge reactors; earthing transformers (neutral couplers); arc-suppression reactors; smoothing reactors for HVDC and industrial application; with the exception of the following reactors: reactors with a rating less than 1 kvar single-phase and 5 kvar three-phase; reactors for special purposes such as high-frequency line traps or reactors mounted on rolling stock. Where IEC standards do not exist for small or special reactors, this part of IEC 60076 may be applicable as a whole or in part.
Contents:
- FOREWORD
- INTRODUCTION
- Scope
- 7.8.10 Dielectric tests
- 7.8.11 Measurement of magnetic characteristic (special test)
- 7.8.12 Measurement of acoustic sound level (type test, special test)
- 7.8.13 Measurement of vibration (type test)
- 7.8.14 Temperature rise test (type test)