IEC 60079-1-1-2002 PDF

IEC 60079-1-1-2002 PDF

Electrical Apparatus for Explosive Gas Atmospheres - Part 1-1: Flameproof Enclosures "d " - Method of Test for Ascertainment of Maximum Experimental Safe Gap

$25.22 $50.44 -50%
Product Code: IEC 60079-1-1
Stock In Stock
Edition: 1.0
Published: 07/2002
Number of Pages: 28
File Size: 1 file, 560 Bytes

Available Options

Product Description

Electrical Apparatus for Explosive Gas Atmospheres - Part 1-1: Flameproof Enclosures "d " - Method of Test for Ascertainment of Maximum Experimental Safe Gap

Scope: This part of IEC 60079 describes a test method intended for the measurement of the maximum experimental safe gaps for gas- or vapour-air mixtures under normal conditions of temperature1 and pressure so as to permit the selection of an appropriate group of flameproof enclosures. The method does not take into account the possible effects of obstacles on the safe gaps2. Definitions For the purpose of this part of IEC 60079, the following definitions apply. 2.1 maximum experimental safe gap MESG maximum gap between the two parts of the interior chamber which, under the test conditions specified below, prevents ignition of the external gas mixture through a 25 mm long flame path when the internal mixture is ignited, for all concentrations of the tested gas or vapour in air Outline of method The interior and exterior chambers of the test apparatus are filled with a known mixture of the gas or vapour in air, under normal conditions of temperature3 and pressure (20 °C, 105 N/m2) and with the circumferential gap between the two chambers accurately adjusted to the desired value. The internal mixture is ignited and the flame propagation, if any, is observed through the windows in the external chamber. The maximum experimental safe gap for the ___________ 1 An exception if made for substances with vapour pressures which are too low to permit mixtures of the required concentrations to be prepared at normal ambient temperatures. For these substances, a temperature 5 °C above that needed to give the necessary vapour pressure is used. 2 The design of the test apparatus for safe gap determination, other than that used for selecting the appropriate group of enclosure for a particular gas, may need to be different to the one described in this standard. For example, the volume of the enclosure, flange width, gas concentrations and the distance between the flanges and any external wall or obstruction may have to be varied. As the design depends on the particular investigation which is to be undertaken, it is unpracticable to recommend specific design requirements, but for most applications the general principles and precautions indicated in the clauses of this standard will still ap

Be the first to write a review for this product.

Write a review

Note: HTML is not translated!
Bad           Good
IEC 60079-1-1-2002 PDF

IEC 60079-1-1-2002 PDF

$25.22 $50.44