Explosive atmospheres - Part 28: Protection of equipment and transmission systems using optical radiation
Introduction: Optical systems in the form of light sources utilizing optical components such as filters or lenses, optical fibres etc. include but are not limited to communications, surveying, sensing and measurement. In material processing, optical radiation of high irradiance is used. Where the installation is inside or close to explosive atmospheres, the radiation from such systems can pass through these atmospheres. Depending on the characteristics of the radiation it might then be able to ignite a surrounding explosive atmosphere. The presence or absence of an additional absorber, such as particles, significantly influences the ignition. There are four possible ignition mechanisms: a) Optical radiation is absorbed by surfaces or particles, causing them to heat up, and under certain circumstances this might allow them to attain a temperature which will ignite a surrounding explosive atmosphere. b) Thermal ignition of a gas volume, where the optical wavelength matches an absorption band of the gas or vapour. c) Photochemical ignition due to photo dissociation of oxygen molecules by radiation in the ultraviolet wavelength range. d) Direct laser induced breakdown of the gas or vapour at the focus of a strong beam, producing plasma and a shock wave both eventually acting as ignition source. These processes can be supported by a solid material close to the breakdown point. The most likely case of ignition occurring in practice with lowest radiation power of ignition capability is case a). U
Scope: This part of IEC 60079 specifies additional requirements for Ex Equipment, Ex associated equipment or Ex Components containing optical systems emitting optical radiation, which is exposed to explosive atmospheres. These additional requirements are applicable for all equipment groups and all Equipment Protection Levels (EPL). This document contains requirements for optical radiation in the wavelength range from 380 nm to 10 µm. It covers the following ignition mechanisms: Optical radiation is absorbed by surfaces or particles, causing them to heat up, and under certain circumstances this might allow them to attain a temperature which will ignite a surrounding explosive atmosphere. In rare special cases, direct laser induced breakdown of the gas at the focus of a strong beam, producing plasma and a shock wave both eventually acting as ignition source. These processes can be supported by a solid material close to the breakdown point. Annex A provides guidance when considering ignition mechanisms that influence the hazard of optics in explosive atmospheres. NOTE 1 See a) and d) of the Introduction. This document applies to a) laser equipment; and b) optical fibre equipment; and c) any optical system that converts light into convergent beams with focal points within the hazardous area only. This document does not apply to: d) laser equipment for EPL Mb, Gb, Gc, Db or Dc applications which complies with Class 1 limits in accordance with IEC 60825-1; or NOTE 2 The Class 1 limits are below 15 mW measured at a distance from the optical radiation source in accordance with IEC 60825-1, with this measured distance reflected in the Ex application. The Class 1 limit values are not considered capable of igniting an explosive atmosphere. NOTE 3 Compliance with Class 1 limits is typically documented in the form of a datasheet or user manual provided by the manufacturer of the laser equipment. e) Single or multiple optical fibre cables not part of optical fibre equipment if the cables: 1) comply with the relevant industrial standards for optical fibre cables, along with additional protective means, for example robust cabling, conduit or raceway (for EPL Gb, Db, Mb, Gc or Dc); or
Contents:
- FOREWORD
- INTRODUCTION
- Scope