Explosive atmospheres – Part 35-1: Caplights for use in mines susceptible to firedamp – General requirements – Construction and testing in relation to the risk of explosion
Introduction: The general revision and updating of this second edition have been necessitated by the advent of new technologies related to caplight design, in particular those related to lithium batteries and light-emitting diode (LED) light sources, the growing practice of incorporating electronic circuits and the introduction of intrinsically safe caplights which can be certified without reference to performance requirements. It is intended that there should be a stronger link between Part 1 (Construction) and Part 2 (Performance) of this Standard by upgrading the reference in the Scope from a note to a requirement. In addition, as this standard is now to become part of the IEC 60079 series, changes have been made to bring it more in line with others in the series by cross referencing. This has enabled a reduction in the number and length of clauses in the standard.
Scope: This part of IEC 60079-35 specifies requirements for the construction, testing and marking of caplights, including caplights with a point of connection for other equipment, for use in mines susceptible to firedamp (Group I – electrical equipment for explosive gas atmospheres as defined in IEC 60079-0). It deals only with the risk of the caplight becoming a source of ignition. The requirements for performance are in IEC 60079-35-2. This standard supplements and modifies the general requirements of IEC 60079-0 except as indicated in Table 1. Where a requirement of this standard conflicts with a requirement of IEC 60079-0, the requirements of this standard take precedence. Compliance with this standard will provide an EPL of Mb (see 4.1 of this standard). If an EPL of Ma is required, the caplight will need to conform to the requirements of 4.2 of this standard, which in turn refers to IEC 60079-11. It is expected that from time to time, caplights conforming to this standard (EPL Mb) will operate in atmospheres where the firedamp exceeds statutory levels that require the withdrawal of people from the high firedamp atmosphere to a non-hazardous area. In designing equipment for operation in conditions other than those given above, this standard may be used as guidance; however, additional testing may be required. Where a caplight is assessed as intrinsically safe equipment, Ex ia, conforming to IEC 60079- 11 only the clauses/subclauses listed in 4.2 require application. ————————— 1 IEC 60079-35-2, Caplights for use in mines susceptible to firedamp – Part 2: Performance and other safety- related matters (to be published). – 8 – 60079-35-1 IEC:2011 Table 1 – Application or exclusion of specific clauses of IEC 60079-0 Clause of IEC 60079-0 IEC 60079-0 clause application Ed. 5.0a (2007) Ed. 6.0a (2011) Clause/subclause title (normative) Scope Applies
Contents:
- FOREWORD
- INTRODUCTION
- Scope
- 5.10 Thermal protection
- 8.10 Current-limiting resistor test
- 8.10.1 Current-limiting resistor not protected by a non-replaceable
- 8.10.2 Current-limiting resistor protected by a non-replaceable resettable
- 8.10.3 Verification