Hearing Aids - Part 4: Magnetic Field Strength in Audio-Frequency Induction Loops for Hearing Aid Purposes
Introduction: Audio-frequency induction-loop systems are widely used to provide a means for hearing aid users, whose hearing aids are fitted with induction pick-up coils, generally known as 'telecoils', to minimise the problems of listening when at a distance from a source of sound, shielded from the person speaking by a protective window, and/or in a background noise. Background noise and distance are two of the main causes of hearing aid users being unable to hear satisfactorily in other than face-to-face quiet conditions. Induction-loop systems have been widely installed in churches, theatres and cinemas, for the benefit of hearing-impaired people. The use of induction-loop systems has been extended to many transient communication situations such as ticket offices, bank counters, drive-in/drive-through service locations, lifts/elevators etc. The widespread provision of telephone handsets that provide inductive coupling to hearing aids is another significant application, where ITU-T Recommendation P370 [1]1 applies. Transmission of an audio-frequency signal via an induction-loop system can often establish an acceptable signal-to-noise ratio in conditions where a purely acoustical transmission would be significantly degraded by reverberation and background noise. One form of audio frequency induction-loop system comprises a cable installed in the form of a loop usually around the perimeter of a room or area in which a group of hearing impaired persons wish to listen. The cable is connecte
Scope: This part of IEC 60118 is applicable to audio-frequency induction-loop systems producing an alternating magnetic field at audio frequencies and intended to provide an input signal for hearing aids operating with an induction pick-up coil (telecoil). Throughout this standard, it is assumed that the hearing aids used with it conform to all relevant parts of IEC 60118. This standard specifies requirements for the field strength in audio-frequency induction loops for hearing aid purposes, which will give adequate signal-to-noise ratio without overloading the hearing aid. The standard also specifies the minimum frequency response requirements for acceptable intelligibility. Methods for measuring the magnetic field strength are specified, and information is given on appropriate measuring equipment (see Annex B), information that should be provided to the operator and users of the system (see Annex C), and other important considerations. This standard does not specify requirements for loop driver amplifiers or associated microphone or audio signal sources, which are dealt with in IEC 62489-1, or for the field strength produced by equipment, such as telephone handsets, within the scope of ITU-T P.370.
Contents:
- FOREWORD
- INTRODUCTION
- Scope