Quartz crystal units of assessed quality – Part 3: Standard outlines and lead connections
Introduction: The third edition of IEC 60122-3 (2004) contained 48 enclosure types showing the dimensional and geometrical characteristics of these enclosures. Since its release, due to progress in technology, many of the enclosures given in the standard have become obsolete. Bearing this in mind, the following 12 enclosure types have been deleted from the third edition of lEC 60122-3. AA, AB, BC, BC/1, BF, BF/1, CX, CY, CY/1, CZ, DA, DC. Therefore, this new version (the fourth edition) contains the following 36 enclosure types ; CK, CM, CN, CP, DK, DL, DP, EH, DQ, DR, DZ, DV, DW, ED, EB, EJ, EK, CU 01A, CU 01B, CU 01C, CU 01D, CU 01E, CU 01F, CU 02A, CU 02B, CU 02C, CU 02D, CU 02E, CU 02F
Scope: This part of IEC 60122 specifies the outline drawing for quartz crystal units with lead enclosures. Guidance for the standardization of outline drawings for frequency control and selection devices 2.1 General In order to achieve a uniform presentation of all outline drawings for frequency control and selection devices the following guide shall be considered: 2.2 An outline drawing shall show all dimensional and geometrical characteristics of an enclosure necessary to ensure mechanical interchangeability with all other enclosures of the same outline. Enlarged detailed view may be used, if necessary. 2.3 The outline drawing shall consist of three parts: 2.3.1 A drawing with dimensional symbols (capital letter) as shown in Figure 1 below with applicable notes, if necessary. 2.3.2 A tabular listing relating to the drawing symbols to the actual dimensions. Where possible this shall be shown on the same page as the drawing. 2.3.3 An "actual-size" sketch (scale 1:1). 2.4 The outline drawing shall be executed in the third angle projection. 2.5 The function and identification of the lead connections (termination) shall be determined by agreement between the supplier and user. They shall not be defined on the outline drawing. 2.6 Descriptive notes may be used at the bottom of/ or adjacent to, the drawing with proper reference to the body of the drawing. 2.7 All dimensions shall be in millimeters. 2.8 Outline dimensions A, B, C, D and E shall be listed with maximum values only. 2.9 Lead (termination) cross-sectional dimensions shall be listed with minimum and maximum values. If applicable, nominal dimensions may be added. 2.10 The spacing of the leads (termination) – symbol H – shall be listed with minimum, nominal and maximum dimensions. – 26 – 60122-3 © CEI:2010 AVANT-PROPOS..................................................................................................................27 INTRODUCTION...................................................................................................................29 Domaine d'application ....................................................................................................30 Guide de normalisation des dessi
Contents:
- FOREWORD
- INTRODUCTION
- Scope