Miniature fuses - Part 4: Universal modular fuse-links (UMF) - Through-hole and surface mount types
Introduction: The trend towards miniaturization of electronic equipment has caused users to require fuse- links of small dimensions, and of appropriate design for application to printed circuit boards or other substrate systems, possibly by automatic means. These fuse-links should be designed to incorporate a degree of non-interchangeability. Rated voltages of 12,5 V, 25 V, 32 V, 50 V, 63 V, 125 V, and 250 V are specified together with the following characteristics: very quick acting (FF), quick acting (F), time-lag (T) and long time- lag (TT). Because of the increasing importance of limitation of transient overvoltages in new technology, recommendations are included for limits to the overvoltages produced by these fuses under specified test conditions related to typical circuit configurations. The option is given to specify the breaking capacity with alternating current or direct current; it is considered that fuses that meet the d.c. requirement will meet the a.c. requirement; however, testing is required to validate this. Fuses may be dual rated, in which case the manufacturer's literature should be referred to. According to the wish expressed by the users of miniature fuses, all standards, recommendations and other documents relating to miniature fuses should have the same publication number in order to facilitate reference to fuses in other specifications, for example, equipment specifications. Furthermore, a single publication number and subdivision into parts would facilitate the es
Contents: